382357-NIST EXTECH
Hersteller: EXTECH
Category: Insulation Resistance Meters
Description: Meter: grounding resistance; LCD; 4 digit (9999); Sampling: 2x/s
Conform to the norm: CAT II 600V; CAT III 300V; EN 61010
Power supply: battery 6LR61 9V x1
Standard equipment: calibration certificate NIST; case; plate resistor for calibration
Body dimensions: 257x100x47mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Protection: anti-overvoltage OVP
Kind of display used: LCD
Earthing resistance measuring accuracy: ±(2% + 0,5Ω)
Max. diameter of measured cable: 23mm
Sampling: 2x/s
Weight with battery: 640g
Measurement memory: 116
AC current measuring accuracy: ±(2% + 0,3mA)
Type of meter: grounding resistance
Measurement: AC current; earthing resistance; leakage current
Display parameters: 4 digit (9999)
AC current measuring range: 1µA...1mA; 10mA; 100mA; 1A; 4A; 30A
Earthing resistance measuring range: 2...250mΩ; 1Ω; 9999mΩ; 50Ω; 99.99Ω; 200Ω; 400Ω; 600Ω; 1.5kΩ
Measuring instrument features: automatic power-off; autoranging; HOLD function; low battery indicator; settable MIN/MAX alarm thresholds
Anzahl je Verpackung: 1 Stücke
Category: Insulation Resistance Meters
Description: Meter: grounding resistance; LCD; 4 digit (9999); Sampling: 2x/s
Conform to the norm: CAT II 600V; CAT III 300V; EN 61010
Power supply: battery 6LR61 9V x1
Standard equipment: calibration certificate NIST; case; plate resistor for calibration
Body dimensions: 257x100x47mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Protection: anti-overvoltage OVP
Kind of display used: LCD
Earthing resistance measuring accuracy: ±(2% + 0,5Ω)
Max. diameter of measured cable: 23mm
Sampling: 2x/s
Weight with battery: 640g
Measurement memory: 116
AC current measuring accuracy: ±(2% + 0,3mA)
Type of meter: grounding resistance
Measurement: AC current; earthing resistance; leakage current
Display parameters: 4 digit (9999)
AC current measuring range: 1µA...1mA; 10mA; 100mA; 1A; 4A; 30A
Earthing resistance measuring range: 2...250mΩ; 1Ω; 9999mΩ; 50Ω; 99.99Ω; 200Ω; 400Ω; 600Ω; 1.5kΩ
Measuring instrument features: automatic power-off; autoranging; HOLD function; low battery indicator; settable MIN/MAX alarm thresholds
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
Produktrezensionen
Produktbewertung abgeben
Technische Details 382357-NIST EXTECH
Category: Insulation Resistance Meters, Description: Meter: grounding resistance; LCD; 4 digit (9999); Sampling: 2x/s, Conform to the norm: CAT II 600V; CAT III 300V; EN 61010, Power supply: battery 6LR61 9V x1, Standard equipment: calibration certificate NIST; case; plate resistor for calibration, Body dimensions: 257x100x47mm, Battery/ rechargeable battery: battery 6LR61 9V x1, Protection: anti-overvoltage OVP, Kind of display used: LCD, Earthing resistance measuring accuracy: ±(2% + 0,5Ω), Max. diameter of measured cable: 23mm, Sampling: 2x/s, Weight with battery: 640g, Measurement memory: 116, AC current measuring accuracy: ±(2% + 0,3mA), Type of meter: grounding resistance, Measurement: AC current; earthing resistance; leakage current, Display parameters: 4 digit (9999), AC current measuring range: 1µA...1mA; 10mA; 100mA; 1A; 4A; 30A, Earthing resistance measuring range: 2...250mΩ; 1Ω; 9999mΩ; 50Ω; 99.99Ω; 200Ω; 400Ω; 600Ω; 1.5kΩ, Measuring instrument features: automatic power-off; autoranging; HOLD function; low battery indicator; settable MIN/MAX alarm thresholds, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote 382357-NIST
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt |
---|---|---|---|---|---|
382357-NIST | Hersteller : Teledyne FLIR | Clamp-On Ground Resistance Tester with Calibration Traceable to NIST |
Produkt ist nicht verfügbar |
||
382357-NIST | Hersteller : FLIR Extech | Description: RESISTANCE TESTER W/NIST 382357 |
Produkt ist nicht verfügbar |
||
382357-NIST | Hersteller : Extech | Clamp Multimeters & Accessories Resistance Tester W/NIST 382357 |
Produkt ist nicht verfügbar |
||
382357-NIST | Hersteller : EXTECH |
Category: Insulation Resistance Meters Description: Meter: grounding resistance; LCD; 4 digit (9999); Sampling: 2x/s Conform to the norm: CAT II 600V; CAT III 300V; EN 61010 Power supply: battery 6LR61 9V x1 Standard equipment: calibration certificate NIST; case; plate resistor for calibration Body dimensions: 257x100x47mm Battery/ rechargeable battery: battery 6LR61 9V x1 Protection: anti-overvoltage OVP Kind of display used: LCD Earthing resistance measuring accuracy: ±(2% + 0,5Ω) Max. diameter of measured cable: 23mm Sampling: 2x/s Weight with battery: 640g Measurement memory: 116 AC current measuring accuracy: ±(2% + 0,3mA) Type of meter: grounding resistance Measurement: AC current; earthing resistance; leakage current Display parameters: 4 digit (9999) AC current measuring range: 1µA...1mA; 10mA; 100mA; 1A; 4A; 30A Earthing resistance measuring range: 2...250mΩ; 1Ω; 9999mΩ; 50Ω; 99.99Ω; 200Ω; 400Ω; 600Ω; 1.5kΩ Measuring instrument features: automatic power-off; autoranging; HOLD function; low battery indicator; settable MIN/MAX alarm thresholds |
Produkt ist nicht verfügbar |