Produkte > FLUKE > FLUKE 28 II EX
FLUKE 28 II EX
  • FLUKE 28 II EX
  • FLUKE 28 II EX
  • FLUKE 28 II EX
  • FLUKE 28 II EX
  • FLUKE 28 II EX
  • FLUKE 28 II EX

FLUKE 28 II EX


Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf Fluke 28-II Manual EN.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: test leads
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Display parameters: (6000/19999)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
auf Bestellung 1 Stücke:

Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2453.88 EUR
Produktrezensionen
Produktbewertung abgeben

Technische Details FLUKE 28 II EX FLUKE

Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Standard equipment: test leads, Temperature measuring range: -200...1090°C, True effective value measurement: True RMS, Bargraph: 33 segm. 40x/s, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature, Dimensions (W x H x D): 100x198x63.5mm, AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A, Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ, DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A, DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz, Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF, Diode test: 1mA @2.8V, Battery/ rechargeable battery: battery LR03 AAA 1,5V x3, Display parameters: (6000/19999), Frequency measuring accuracy: ±(0.005%+1 digit), Capacitance measuring accuracy: ±(1%+ 2 digit), AC current measuring accuracy: ±(1% + 2 digit), DC voltage measuring accuracy: ±(0.05% + 1 digit), DC current measuring accuracy: ±(0.2% + 2 digit), AC voltage measuring accuracy: ±(1% + 4 digit), Conductance measuring accuracy: ±(1% + 10digit), Resistance measuring accuracy: ±(0.2%+1 digit), Temperature measurement accuracy: ±(1% + 10 digit), Kind of display used: LCD, Power supply: battery LR03 AAA 1,5V x3, IP rating: IP67, Illumination: yes, Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case, Type of meter: digital multimeter, Weight with battery: 517g, Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71, Continuity test: acoustic indication, Duty cycle factor: 0...99.9%, Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%, Temperature measurement resolution: 0.1°C, Conductance measurement: 0.01...60nS, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote FLUKE 28 II EX nach Preis ab 2453.88 EUR bis 2453.88 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
FLUKE 28 II EX
+5
FLUKE 28 II EX Hersteller : FLUKE Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf Fluke 28-II Manual EN.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: test leads
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Dimensions (W x H x D): 100x198x63.5mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @2.8V
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Display parameters: (6000/19999)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR03 AAA 1,5V x3
IP rating: IP67
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Type of meter: digital multimeter
Weight with battery: 517g
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2453.88 EUR
FLUKE 28 II EX FLUKE 28 II EX Hersteller : FLUKE 2875665.pdf Description: FLUKE - FLUKE 28 II EX - Digitalmultimeter, eigensicher, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 10A
Messwert Wechselstrom, max.: 10A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 50Mohm
usEccn: 3A992.a
Produktpalette: Knipex - Diagonal Side Cutters
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)