Produkte > FLUKE > FLUKE 787B
FLUKE 787B
  • FLUKE 787B
  • FLUKE 787B
  • FLUKE 787B
  • FLUKE 787B
  • FLUKE 787B
  • FLUKE 787B

FLUKE 787B


FLK-787B.pdf FLK-787B-INS.pdf Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Continuity test: acoustic indication; <100Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:

Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1881.98 EUR
Produktrezensionen
Produktbewertung abgeben

Technische Details FLUKE 787B FLUKE

Category: Calibrators, Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010, Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71, Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set, Related items: POM-5900A/POM; POM-6173A; POM-7519A, AC current measuring range: 0.001mA...1A, Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ, DC current measuring range: 1µA...30mA; 1A, DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV, AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV, Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz, Diode test: 0.3mA @600mV, Battery/ rechargeable battery: battery LR6 AA 1,5V x4, Software: Fluke Connect (FLK-IR3000FC), Frequency measuring accuracy: ±(0.005%+1 digit), AC current measuring accuracy: ±(1% + 2 digit), DC voltage measuring accuracy: ±(0.1% + 1 digit), DC current measuring accuracy: ±(0.2% + 2 digit), AC voltage measuring accuracy: ±(0.7% + 2 digit), Resistance measuring accuracy: ±(0.2%+1 digit), Kind of display used: LCD, Power supply: battery LR6 AA 1,5V x4, Dimensions: 203x100x50mm, Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate, Type of meter: multimeter calibrator, Continuity test: acoustic indication; .

Weitere Produktangebote FLUKE 787B nach Preis ab 1881.98 EUR bis 3122.6 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
FLUKE 787B
+5
FLUKE 787B Hersteller : FLUKE FLK-787B.pdf FLK-787B-INS.pdf Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Related items: POM-5900A/POM; POM-6173A; POM-7519A
AC current measuring range: 0.001mA...1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Diode test: 0.3mA @600mV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring accuracy: ±(0.005%+1 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Type of meter: multimeter calibrator
Continuity test: acoustic indication; <100Ω
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+1881.98 EUR
FLUKE-787B FLUKE-787B Hersteller : Fluke Electronics 6008812b-en-787b-789-ds-w.pdf?NUjGpSJo72izmwoD_Dv42O26X2Vw.vN9 Description: PROCESS METER
Packaging: Bulk
Features: Min/Max/Ave
Display Type: LCD, Dual
Style: Handheld
Function: Voltage, Current, Resistance, Frequency
Type: Digital (DMM)
Ranging: Auto/Manual
Display Count: 4000
Functions, Extra: Battery Test, Diode Test
Response: True RMS
Part Status: Active
Display Digits: 3.75
auf Bestellung 8 Stücke:
Lieferzeit 21-28 Tag (e)
Anzahl Preis ohne MwSt
1+3122.6 EUR
FLUKE 787B FLUKE 787B Hersteller : FLUKE 2236519.pdf Description: FLUKE - FLUKE 787B - Digitalmultimeter, ProcessMeter, 4000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.75-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 1A
Messwert Wechselstrom, max.: 1A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 40Mohm
usEccn: 3A992.a
Produktpalette: -
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE-787B FLUKE-787B Hersteller : Fluke Fluke_04122017_787B_789-1275427.pdf Digital Multimeters PROCESSMETER
Produkt ist nicht verfügbar