Produkte > FLUKE > FLUKE 87-V
FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V
  • FLUKE 87-V

FLUKE 87-V


Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
DC voltage measuring accuracy: ±(0,05% + 1 digit)
AC voltage measuring accuracy: ±(0,7% + 4 digits)
DC current measuring accuracy: ±(0,2% + 2 digits)
AC current measuring accuracy: ±(1% + 2 digits)
Resistance measuring accuracy: ±(0,2% + 1 digit)
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digits)
Conductance measurement: 0.01...60nS
Conductance measuring accuracy: ±(1% + 10 digits)
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 95x200x48mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Kind of display used: LCD
Power supply: battery 6F22 9V x1
IP rating: IP30
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Anzahl je Verpackung: 1 Stücke
auf Bestellung 14 Stücke:

Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+813.67 EUR
Produktrezensionen
Produktbewertung abgeben

Technische Details FLUKE 87-V FLUKE

Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Type of meter: digital multimeter, DC voltage measuring accuracy: ±(0,05% + 1 digit), AC voltage measuring accuracy: ±(0,7% + 4 digits), DC current measuring accuracy: ±(0,2% + 2 digits), AC current measuring accuracy: ±(1% + 2 digits), Resistance measuring accuracy: ±(0,2% + 1 digit), Weight with battery: 600g, Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter, Continuity test: acoustic indication, Pollution degree: 2, Temperature measurement resolution: 0.1°C, Temperature measurement accuracy: ±(1% + 10 digits), Conductance measurement: 0.01...60nS, Conductance measuring accuracy: ±(1% + 10 digits), Temperature measuring range: -200...1090°C, True effective value measurement: True RMS AC, Bargraph: 33 segm. 40x/s, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Dimensions (W x H x D): 95x200x48mm, AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A .

Weitere Produktangebote FLUKE 87-V nach Preis ab 813.67 EUR bis 813.67 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
FLUKE 87-V
+6
FLUKE 87-V Hersteller : FLUKE Fluke 87 V Datasheet (EN).pdf Fluke 87 V Datasheet (DE).pdf Fluke 87 V Manual (EN).pdf Fluke 87 V Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
DC voltage measuring accuracy: ±(0,05% + 1 digit)
AC voltage measuring accuracy: ±(0,7% + 4 digits)
DC current measuring accuracy: ±(0,2% + 2 digits)
AC current measuring accuracy: ±(1% + 2 digits)
Resistance measuring accuracy: ±(0,2% + 1 digit)
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digits)
Conductance measurement: 0.01...60nS
Conductance measuring accuracy: ±(1% + 10 digits)
Temperature measuring range: -200...1090°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 95x200x48mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery 6F22 9V x1
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Kind of display used: LCD
Power supply: battery 6F22 9V x1
IP rating: IP30
Illumination: yes
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
auf Bestellung 14 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+813.67 EUR
FLK-87V
Produktcode: 105244
Hersteller : Fluke Werkzeuge und Geräte > Messgeräte
Produkt ist nicht verfügbar
FLUKE-87-V FLUKE-87-V Hersteller : Fluke 2137623_6116_ENG_B_W-19107.pdf Digital Multimeters TRUE RMS MULTIMETER
Produkt ist nicht verfügbar