FLUKE-87V-MAX/E2 KIT
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Temperature measuring range: -200...1090°C
IP rating: IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Power supply: battery LR6 AA 1,5V x3
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Illumination: yes
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Temperature measuring range: -200...1090°C
IP rating: IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Power supply: battery LR6 AA 1,5V x3
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Illumination: yes
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 63x198x100mm
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @3V
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Display parameters: (6000/20000)
Frequency measuring accuracy: ±(0.005%+1 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis ohne MwSt |
---|---|
1+ | 1118.65 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE-87V-MAX/E2 KIT FLUKE
Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s, Temperature measuring range: -200...1090°C, IP rating: IP67, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B, Power supply: battery LR6 AA 1,5V x3, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Kind of display used: LCD, Illumination: yes, Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238, Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation, Type of meter: digital multimeter, Weight with battery: 700g, Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter, Continuity test: acoustic indication, Pollution degree: 2, Temperature measurement resolution: 0.1°C, Conductance measurement: 0.01...60nS, True effective value measurement: True RMS AC, Bargraph: 33 segm. 40x/s, Dimensions (W x H x D): 63x198x100mm, AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A .
Weitere Produktangebote FLUKE-87V-MAX/E2 KIT nach Preis ab 1118.65 EUR bis 2017.57 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
+3 |
FLUKE-87V-MAX/E2 KIT | Hersteller : FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Temperature measuring range: -200...1090°C IP rating: IP67 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Power supply: battery LR6 AA 1,5V x3 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Illumination: yes Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Type of meter: digital multimeter Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Dimensions (W x H x D): 63x198x100mm AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @3V Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Display parameters: (6000/20000) Frequency measuring accuracy: ±(0.005%+1 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
FLUKE-87V-MAX/E2 KIT | Hersteller : Fluke Electronics |
Description: INDUSTRIAL TRUE RMS HEAVY DUTY M Features: Backlight, Hold Packaging: Bulk Display Type: LCD Style: Handheld Function: Capacitance, Current, Frequency, Resistance, Temperature, Voltage Type: Digital (DMM) Ranging: Auto Ratings: CAT IV 600V, CAT III 1000V Display Count: 19999 Functions, Extra: Continuity Test, Diode Test Response: True RMS Part Status: Active Display Digits: 5 |
auf Bestellung 1 Stücke: Lieferzeit 21-28 Tag (e) |
|
|||||||
FLUKE-87V-MAX/E2 KIT | Hersteller : FLUKE |
Description: FLUKE - FLUKE-87V-MAX/E2 KIT - Kit, TRMS-Digitalmultimeter, 1kV AC/DC, Industrie, IP67 tariffCode: 90308900 productTraceability: No rohsCompliant: Y-EX euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: -888 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||
FLUKE-87V-MAX/E2-KIT | Hersteller : Fluke | FLUKE-87V-MAX/E2-KIT |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||||
FLUKE-87V-MAX/E2 KIT | Hersteller : Fluke | Digital Multimeters INDUSTRIAL TRUE RMS HEAVY DUTY MULTIMETER COMBO KIT |