Suchergebnisse für "TL-EARTH" : 2
Art der Ansicht :
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt |
---|---|---|---|---|---|
GRT300-NISTL | EXTECH |
Category: Earth Resistance Meter Description: Meter: grounding resistance; LCD; 2mA@820Hz; Pollution degree: 2 Type of meter: grounding resistance Kind of display used: LCD Measurement: earthing resistance; resistance (2-wire); resistance (3-wire); resistance (4-wire) Body dimensions: 250x190x110mm Power supply: battery LR6 AA 1,5V x8 Conform to the norm: CAT IV 300V; EN 61010 Measuring instrument features: automatic power-off; autoranging; autozeroing; HOLD function; low battery indicator Standard equipment: calibration certificate NIST Pollution degree: 2 Test voltage: 300V Test current: 2mA @ 820Hz Earthing resistance measuring range: 10mΩ...2Ω; 20Ω; 200Ω; 2kΩ Earthing resistance measuring accuracy: ±(2% + 3 digit) Anzahl je Verpackung: 1 Stücke |
Produkt ist nicht verfügbar |
GRT300-NISTL |
Hersteller: EXTECH
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; 2mA@820Hz; Pollution degree: 2
Type of meter: grounding resistance
Kind of display used: LCD
Measurement: earthing resistance; resistance (2-wire); resistance (3-wire); resistance (4-wire)
Body dimensions: 250x190x110mm
Power supply: battery LR6 AA 1,5V x8
Conform to the norm: CAT IV 300V; EN 61010
Measuring instrument features: automatic power-off; autoranging; autozeroing; HOLD function; low battery indicator
Standard equipment: calibration certificate NIST
Pollution degree: 2
Test voltage: 300V
Test current: 2mA @ 820Hz
Earthing resistance measuring range: 10mΩ...2Ω; 20Ω; 200Ω; 2kΩ
Earthing resistance measuring accuracy: ±(2% + 3 digit)
Anzahl je Verpackung: 1 Stücke
Category: Earth Resistance Meter
Description: Meter: grounding resistance; LCD; 2mA@820Hz; Pollution degree: 2
Type of meter: grounding resistance
Kind of display used: LCD
Measurement: earthing resistance; resistance (2-wire); resistance (3-wire); resistance (4-wire)
Body dimensions: 250x190x110mm
Power supply: battery LR6 AA 1,5V x8
Conform to the norm: CAT IV 300V; EN 61010
Measuring instrument features: automatic power-off; autoranging; autozeroing; HOLD function; low battery indicator
Standard equipment: calibration certificate NIST
Pollution degree: 2
Test voltage: 300V
Test current: 2mA @ 820Hz
Earthing resistance measuring range: 10mΩ...2Ω; 20Ω; 200Ω; 2kΩ
Earthing resistance measuring accuracy: ±(2% + 3 digit)
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar