AX-380 AXIOMET
Hersteller: AXIOMETCategory: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 55mm; LCD
Operating temperature: 0...40°C
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: none
Type of meter: multifunction
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Kind of display used: LCD
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 100µF
DC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 400mV; 4V; 40V; 400V; 750V
AC current measuring range: 400A; 2kA
DC current measuring range: 400A; 2kA
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 5.12Hz; 51.2Hz; 512Hz; 5.12kHz; 51.2kHz; 100kHz; 512kHz
Frequency measuring accuracy: ±(0.5%+4 digit)
Max. diameter of measured cable: 55mm
DC voltage measuring accuracy: ±(0.5% + 4 digit)
Dimensions: 275x96x50mm
Resistance measuring accuracy: ±(0.8%+4 digit)
DC current measuring accuracy: ±(3.5% + 20 digit)
AC voltage measuring accuracy: ±(0.8% + 10 digit)
AC current measuring accuracy: ±(3% + 10 digit)
Capacitance measuring accuracy: ±(3.5%+ 8 digit)
Display parameters: 3,5 digit (3999)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Standard equipment: test leads
Measuring instrument features: automatic power-off; display zeroing function in DCA measurements; HOLD function; low battery indicator; REL function
Test: diodes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 2+ | 66.38 EUR |
| 3+ | 60.95 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details AX-380 AXIOMET
Category: Meters and AC/DC Clamp Probes, Description: Meter: multifunction; digital,pincers type; Øcable: 55mm; LCD, Operating temperature: 0...40°C, Power supply: battery 6F22 9V x1, Battery/ rechargeable battery: none, Type of meter: multifunction, Conform to the norm: CAT III 600V; EN 61010, Kind of meter: digital; pincers type, Kind of display used: LCD, Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 100µF, DC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV, AC voltage measuring range: 400mV; 4V; 40V; 400V; 750V, AC current measuring range: 400A; 2kA, DC current measuring range: 400A; 2kA, Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ, Frequency measuring range: 5.12Hz; 51.2Hz; 512Hz; 5.12kHz; 51.2kHz; 100kHz; 512kHz, Frequency measuring accuracy: ±(0.5%+4 digit), Max. diameter of measured cable: 55mm, DC voltage measuring accuracy: ±(0.5% + 4 digit), Dimensions: 275x96x50mm, Resistance measuring accuracy: ±(0.8%+4 digit), DC current measuring accuracy: ±(3.5% + 20 digit), AC voltage measuring accuracy: ±(0.8% + 10 digit), AC current measuring accuracy: ±(3% + 10 digit), Capacitance measuring accuracy: ±(3.5%+ 8 digit), Display parameters: 3,5 digit (3999), Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance, Continuity test: acoustic indication, Standard equipment: test leads, Measuring instrument features: automatic power-off; display zeroing function in DCA measurements; HOLD function; low battery indicator; REL function, Test: diodes, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote AX-380 nach Preis ab 60.95 EUR bis 66.38 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() +3 |
AX-380 | Hersteller : AXIOMET |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 55mm; LCD Operating temperature: 0...40°C Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: none Type of meter: multifunction Conform to the norm: CAT III 600V; EN 61010 Kind of meter: digital; pincers type Kind of display used: LCD Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 100µF DC voltage measuring range: 400mV; 4V; 40V; 400V; 1kV AC voltage measuring range: 400mV; 4V; 40V; 400V; 750V AC current measuring range: 400A; 2kA DC current measuring range: 400A; 2kA Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 5.12Hz; 51.2Hz; 512Hz; 5.12kHz; 51.2kHz; 100kHz; 512kHz Frequency measuring accuracy: ±(0.5%+4 digit) Max. diameter of measured cable: 55mm DC voltage measuring accuracy: ±(0.5% + 4 digit) Dimensions: 275x96x50mm Resistance measuring accuracy: ±(0.8%+4 digit) DC current measuring accuracy: ±(3.5% + 20 digit) AC voltage measuring accuracy: ±(0.8% + 10 digit) AC current measuring accuracy: ±(3% + 10 digit) Capacitance measuring accuracy: ±(3.5%+ 8 digit) Display parameters: 3,5 digit (3999) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Standard equipment: test leads Measuring instrument features: automatic power-off; display zeroing function in DCA measurements; HOLD function; low battery indicator; REL function Test: diodes |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|