M5000-V001 GOSSEN METRAWATT
Hersteller: GOSSEN METRAWATT
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 50÷1000V; VDC: 50÷5000V
Supply voltage: 230V AC
Standard equipment: 2 crocodile clips; calibration certificate DAkkS; mains cable; RS232 cable; test leads ( 2pcs.); user's manual
Additional functions: data logger; timer
Measuring instrument features: guard terminal for compensating surface current; inetrface language - German; polarization index (PI) and dielelectric absorption ratio (DAR)
Type of meter: insulation resistance
Measurement: AC voltage; capacitance; DC voltage; electrical discharge; frequency; insulation resistance
Test voltage: 100V; 250V; 500V; 1kV; 1.5kV; 2kV; 2.5kV; 5kV
DC voltage measuring range: 50...5000V
AC voltage measuring range: 50...1000V
Frequency measuring range: 15Hz...1kHz
Capacitance measuring range: 0.1...5µF
Insulation resistance measuring ranges: 400kΩ...50GΩ; 250GΩ; 1TΩ
Frequency measuring accuracy: ±(0.5%+2 digit)
Capacitance measuring accuracy: ±(5%+ 5 digit)
DC voltage measuring accuracy: ±(2.5% + 2 digit)
AC voltage measuring accuracy: ±(2.5% + 2 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH x1
IP rating: IP40
Body dimensions: 255x133x240mm
Conform to the norm: CAT II 1000V; CAT III 600V; CAT IV 300V; EN 61010
Related items: GM-M662A; GM-Z580B; GM-Z580C; GM-Z580D
Anzahl je Verpackung: 1 Stücke
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 50÷1000V; VDC: 50÷5000V
Supply voltage: 230V AC
Standard equipment: 2 crocodile clips; calibration certificate DAkkS; mains cable; RS232 cable; test leads ( 2pcs.); user's manual
Additional functions: data logger; timer
Measuring instrument features: guard terminal for compensating surface current; inetrface language - German; polarization index (PI) and dielelectric absorption ratio (DAR)
Type of meter: insulation resistance
Measurement: AC voltage; capacitance; DC voltage; electrical discharge; frequency; insulation resistance
Test voltage: 100V; 250V; 500V; 1kV; 1.5kV; 2kV; 2.5kV; 5kV
DC voltage measuring range: 50...5000V
AC voltage measuring range: 50...1000V
Frequency measuring range: 15Hz...1kHz
Capacitance measuring range: 0.1...5µF
Insulation resistance measuring ranges: 400kΩ...50GΩ; 250GΩ; 1TΩ
Frequency measuring accuracy: ±(0.5%+2 digit)
Capacitance measuring accuracy: ±(5%+ 5 digit)
DC voltage measuring accuracy: ±(2.5% + 2 digit)
AC voltage measuring accuracy: ±(2.5% + 2 digit)
Kind of display used: LCD
Power supply: rechargeable battery Ni-MH x1
IP rating: IP40
Body dimensions: 255x133x240mm
Conform to the norm: CAT II 1000V; CAT III 600V; CAT IV 300V; EN 61010
Related items: GM-M662A; GM-Z580B; GM-Z580C; GM-Z580D
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
Produktrezensionen
Produktbewertung abgeben
Technische Details M5000-V001 GOSSEN METRAWATT
Category: Insulation Resistance Meters, Description: Meter: insulation resistance; LCD; VAC: 50÷1000V; VDC: 50÷5000V, Supply voltage: 230V AC, Standard equipment: 2 crocodile clips; calibration certificate DAkkS; mains cable; RS232 cable; test leads ( 2pcs.); user's manual, Additional functions: data logger; timer, Measuring instrument features: guard terminal for compensating surface current; inetrface language - German; polarization index (PI) and dielelectric absorption ratio (DAR), Type of meter: insulation resistance, Measurement: AC voltage; capacitance; DC voltage; electrical discharge; frequency; insulation resistance, Test voltage: 100V; 250V; 500V; 1kV; 1.5kV; 2kV; 2.5kV; 5kV, DC voltage measuring range: 50...5000V, AC voltage measuring range: 50...1000V, Frequency measuring range: 15Hz...1kHz, Capacitance measuring range: 0.1...5µF, Insulation resistance measuring ranges: 400kΩ...50GΩ; 250GΩ; 1TΩ, Frequency measuring accuracy: ±(0.5%+2 digit), Capacitance measuring accuracy: ±(5%+ 5 digit), DC voltage measuring accuracy: ±(2.5% + 2 digit), AC voltage measuring accuracy: ±(2.5% + 2 digit), Kind of display used: LCD, Power supply: rechargeable battery Ni-MH x1, IP rating: IP40, Body dimensions: 255x133x240mm, Conform to the norm: CAT II 1000V; CAT III 600V; CAT IV 300V; EN 61010, Related items: GM-M662A; GM-Z580B; GM-Z580C; GM-Z580D, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote M5000-V001
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt |
---|---|---|---|---|---|
+1 |
M5000-V001 | Hersteller : GOSSEN METRAWATT |
Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; VAC: 50÷1000V; VDC: 50÷5000V Supply voltage: 230V AC Standard equipment: 2 crocodile clips; calibration certificate DAkkS; mains cable; RS232 cable; test leads ( 2pcs.); user's manual Additional functions: data logger; timer Measuring instrument features: guard terminal for compensating surface current; inetrface language - German; polarization index (PI) and dielelectric absorption ratio (DAR) Type of meter: insulation resistance Measurement: AC voltage; capacitance; DC voltage; electrical discharge; frequency; insulation resistance Test voltage: 100V; 250V; 500V; 1kV; 1.5kV; 2kV; 2.5kV; 5kV DC voltage measuring range: 50...5000V AC voltage measuring range: 50...1000V Frequency measuring range: 15Hz...1kHz Capacitance measuring range: 0.1...5µF Insulation resistance measuring ranges: 400kΩ...50GΩ; 250GΩ; 1TΩ Frequency measuring accuracy: ±(0.5%+2 digit) Capacitance measuring accuracy: ±(5%+ 5 digit) DC voltage measuring accuracy: ±(2.5% + 2 digit) AC voltage measuring accuracy: ±(2.5% + 2 digit) Kind of display used: LCD Power supply: rechargeable battery Ni-MH x1 IP rating: IP40 Body dimensions: 255x133x240mm Conform to the norm: CAT II 1000V; CAT III 600V; CAT IV 300V; EN 61010 Related items: GM-M662A; GM-Z580B; GM-Z580C; GM-Z580D |
Produkt ist nicht verfügbar |