Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g
Type of meter: power
Kind of meter: pincers type
Kind of display used: LCD
Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance
AC voltage measuring range: 100mV...600V
AC current measuring range: 10mA...40A; 400A; 1kA
DC voltage measuring range: 100mV...600V
Frequency measuring range: 10mHz...5Hz; 500Hz
AC voltage measuring accuracy: ±(0.5% + 5 digit)
AC current measuring accuracy: ±(1% + 5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
True effective value measurement: True RMS AC
Max. diameter of measured cable: 45mm
Interface: RS232 (option); USB
Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Sampling: 1x/s (Hz); 2x/s
Illumination: yes
Dimensions: 224x78x40mm
Active power measuring accuracy: ±(4.5% + 6 digit)
Bandwidth for AC voltage measurements: 40...500Hz
Harmonic content measuring accuracy: ±(1% + 6 digits)
Resistance measuring range: 100mΩ...999.9Ω
Bandwidth for AC current measurements: 40...500Hz
Harmonic content measurement: 0...99,99%
Pollution degree: 2
Continuity test: acoustic indication; 50Ω...250Ω
Optional equipment: KITBRUA-13X software; KITRS232E software
Power factor measurement: 0.01...0.99
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Weight with battery: 224g
Frequency measuring accuracy: ±(0.5%+4 digit)
Resistance measuring accuracy: ±(1%+6 digit)
Reactive power measuring accuracy: ±(4.5% + 6 digit)
Apparent power measuring accuracy: ±(3.5% + 6 digit)
Apparent power measurement: 0...600kVA
Reactive power measurement: 0...600kVAR
auf Bestellung 2 Stücke:

Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+236.51 EUR
Produktrezensionen
Produktbewertung abgeben

Technische Details BM157S BRYMEN

Category: Meters and AC Clamp Probes, Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g, Type of meter: power, Kind of meter: pincers type, Kind of display used: LCD, Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance, AC voltage measuring range: 100mV...600V, AC current measuring range: 10mA...40A; 400A; 1kA, DC voltage measuring range: 100mV...600V, Frequency measuring range: 10mHz...5Hz; 500Hz, AC voltage measuring accuracy: ±(0.5% + 5 digit), AC current measuring accuracy: ±(1% + 5 digit), DC voltage measuring accuracy: ±(0.5% + 5 digit), True effective value measurement: True RMS AC, Max. diameter of measured cable: 45mm, Interface: RS232 (option); USB, Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals, Standard equipment: case; test leads, Conform to the norm: CAT III 600V; EN 61010, Power supply: battery LR03 AAA 1,5V x2, Sampling: 1x/s (Hz); 2x/s, Illumination: yes, Dimensions: 224x78x40mm, Active power measuring accuracy: ±(4.5% + 6 digit), Bandwidth for AC voltage measurements: 40...500Hz, Harmonic content measuring accuracy: ±(1% + 6 digits), Resistance measuring range: 100mΩ...999.9Ω, Bandwidth for AC current measurements: 40...500Hz, Harmonic content measurement: 0...99,99%, Pollution degree: 2, Continuity test: acoustic indication; 50Ω...250Ω, Optional equipment: KITBRUA-13X software; KITRS232E software, Power factor measurement: 0.01...0.99, Battery/ rechargeable battery: battery LR03 AAA 1,5V x2, Weight with battery: 224g, Frequency measuring accuracy: ±(0.5%+4 digit), Resistance measuring accuracy: ±(1%+6 digit), Reactive power measuring accuracy: ±(4.5% + 6 digit), Apparent power measuring accuracy: ±(3.5% + 6 digit), Apparent power measurement: 0...600kVA, Reactive power measurement: 0...600kVAR, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote BM157S nach Preis ab 236.51 EUR bis 236.51 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
BM157S
+5
BM157S Hersteller : BRYMEN BM157.pdf Category: Meters and AC Clamp Probes
Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g
Type of meter: power
Kind of meter: pincers type
Kind of display used: LCD
Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance
AC voltage measuring range: 100mV...600V
AC current measuring range: 10mA...40A; 400A; 1kA
DC voltage measuring range: 100mV...600V
Frequency measuring range: 10mHz...5Hz; 500Hz
AC voltage measuring accuracy: ±(0.5% + 5 digit)
AC current measuring accuracy: ±(1% + 5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
True effective value measurement: True RMS AC
Max. diameter of measured cable: 45mm
Interface: RS232 (option); USB
Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Sampling: 1x/s (Hz); 2x/s
Illumination: yes
Dimensions: 224x78x40mm
Active power measuring accuracy: ±(4.5% + 6 digit)
Bandwidth for AC voltage measurements: 40...500Hz
Harmonic content measuring accuracy: ±(1% + 6 digits)
Resistance measuring range: 100mΩ...999.9Ω
Bandwidth for AC current measurements: 40...500Hz
Harmonic content measurement: 0...99,99%
Pollution degree: 2
Continuity test: acoustic indication; 50Ω...250Ω
Optional equipment: KITBRUA-13X software; KITRS232E software
Power factor measurement: 0.01...0.99
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Weight with battery: 224g
Frequency measuring accuracy: ±(0.5%+4 digit)
Resistance measuring accuracy: ±(1%+6 digit)
Reactive power measuring accuracy: ±(4.5% + 6 digit)
Apparent power measuring accuracy: ±(3.5% + 6 digit)
Apparent power measurement: 0...600kVA
Reactive power measurement: 0...600kVAR