Produkte > FLUKE > FLUKE 705
FLUKE 705

FLUKE 705


605993.pdf Hersteller: FLUKE
Description: FLUKE - FLUKE 705 - Kalibrator, Stromschleifenkalibrator, 4 bis 20mA, Strom, Spannung, 164 mm, 75 mm, 47 mm, 0.0002
tariffCode: 90303370
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: YES
Kalibrierung: Strom, Spannung
usEccn: 3A992.a
Betriebstemperatur, min.: -10°C
Außentiefe: 47mm
Außenbreite: 75mm
euEccn: NLR
Außenhöhe: 164mm
Produktpalette: -
productTraceability: No
Genauigkeit: 0.0002
Gewicht: 350g
Betriebstemperatur, max.: 55°C
SVHC: No SVHC (17-Jan-2023)
auf Bestellung 5 Stücke:

Lieferzeit 14-21 Tag (e)
Produktrezensionen
Produktbewertung abgeben

Technische Details FLUKE 705 FLUKE

Category: Calibrators, Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA, Dimensions: 201x98x52mm, Kind of display used: LCD, Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate, Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps, Type of meter: calibrator, Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221, Kind of calibrator: loop, Current source accuracy: ±(0,025% + 2 digits), Measurement: DC current; DC voltage, DC current measuring range: 0.001...24mA, DC voltage measuring range: 1mV...28V, Current source: 0...20mA; 4...20mA, DC voltage measuring accuracy: ±(0.025% + 1 digit), DC current measuring accuracy: ±(0.025% + 2 digit), Power supply: battery 6F22 9V x1, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote FLUKE 705

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
FLUKE 705
+2
FLUKE 705 Hersteller : FLUKE Fluke 705 Datasheet (EN).pdf Fluke 705 Manual (EN).pdf Fluke 705 Manual (DE).pdf Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Dimensions: 201x98x52mm
Kind of display used: LCD
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Type of meter: calibrator
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of calibrator: loop
Current source accuracy: ±(0,025% + 2 digits)
Measurement: DC current; DC voltage
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
Current source: 0...20mA; 4...20mA
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Power supply: battery 6F22 9V x1
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
FLUKE-705 Hersteller : Fluke Electronics Description: LOOP CALIBRATOR
Produkt ist nicht verfügbar
FLUKE-705 FLUKE-705 Hersteller : Fluke 705_____iseng0200-8907.pdf Calibration Equipment LOOP CALIBRATOR
Produkt ist nicht verfügbar
FLUKE 705
+2
FLUKE 705 Hersteller : FLUKE Fluke 705 Datasheet (EN).pdf Fluke 705 Manual (EN).pdf Fluke 705 Manual (DE).pdf Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Dimensions: 201x98x52mm
Kind of display used: LCD
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Type of meter: calibrator
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of calibrator: loop
Current source accuracy: ±(0,025% + 2 digits)
Measurement: DC current; DC voltage
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
Current source: 0...20mA; 4...20mA
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Power supply: battery 6F22 9V x1
Produkt ist nicht verfügbar