| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
||||
|---|---|---|---|---|---|---|---|---|---|
![]() +4 |
FLUKE-115 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Manufacturer series: Fluke 110 Type of meter: digital multimeter Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Standard equipment: FLK-TL75 test leads Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V DC current measuring range: 1mA...6A; 10A; 20A < 30s AC current measuring range: 1mA...6A; 10A; (20A <30s) Diode test: 1.2mA @2.7V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Dimensions (W x H x D): 84x167x46mm Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω Related items: POM-5543B; POM-6275; POM-6343 Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 |
auf Bestellung 117 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +4 |
FLUKE-116 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Conform to the norm: CAT III 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Kind of display used: LCD Type of meter: digital multimeter Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA DC current measuring range: 0.1...600µA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm Temperature measurement accuracy: ±(0.1% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Weight with battery: 550g Standard equipment: FLK-TL75 test leads Display parameters: 3,75 digit (6000) Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Continuity test: acoustic indication; <20Ω Measuring instruments application: air conditioning; heating industry; ventilation Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 |
auf Bestellung 25 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +10 |
FLUKE-116/323 KIT | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 Type of measuring kit: multimeters |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-117 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 600V; EN 61010 Manufacturer series: Fluke 110 Type of meter: digital multimeter Related items: POM-5673B; POM-5900A/POM; POM-7519A Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 1mA...6A; 10A; 20A < 30s AC current measuring range: 1mA...6A; 10A; (20A <30s) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster |
auf Bestellung 78 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +7 |
FLUKE-117/323 EUR | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Type of measuring kit: multimeters Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 |
auf Bestellung 16 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +3 |
FLUKE-123B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Type of oscilloscope: scopemeter Band: 20MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 20n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe Related items: POM-72941; POM-72942 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +15 |
FLUKE-123B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Type of oscilloscope: scopemeter Band: 20MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 20n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe Related items: POM-72941; POM-72942 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +16 |
FLUKE-124B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe Related items: POM-72941; POM-72942 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +15 |
FLUKE-124B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe Related items: POM-72941; POM-72942 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-125B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Connectors for the country: Europe Related items: POM-72941; POM-72942 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +16 |
FLUKE-125B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Type of oscilloscope: scopemeter Band: 40MHz Kind of display used: colour; LCD TFT 5,7" Number of channels: 2 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Sampling: 40Msps Time base: 10n...60s/div Display resolution: 640x480 DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Resistance measuring accuracy: ±(0.6%+5 digit) Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Continuity test: acoustic indication Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Dimensions: 259x132x55mm Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 IP rating: IP51 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Manufacturer series: FLUKE 120B Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Software: Fluke View Connectors for the country: Europe |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +1 |
FLUKE-1503 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Conform to the norm: CAT IV 600V; EN 61010 Type of meter: insulation resistance Related items: POM-5674C; POM-5907A; POM-6041B IP rating: IP40 Kind of display used: LCD Illumination: yes DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ Automatic discharging capacitance: max. 1µF DC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.5%+3 digit) Body dimensions: 203x100x50mm Capacitance discharge time: <0.5s AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Open circuit test voltage: 4...8V Bandwidth for AC voltage measurements: 50...400Hz Test voltage: 500V DC; 1kV DC Weight with battery: 550g Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC voltage; DC voltage; insulation resistance; resistance Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-1507 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Conform to the norm: CAT IV 600V; EN 61010 Type of meter: insulation resistance Related items: POM-5674C; POM-5907A; POM-6041B IP rating: IP40 Kind of display used: LCD Illumination: yes DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ Automatic discharging capacitance: max. 1µF DC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.5%+3 digit) Body dimensions: 203x100x50mm Capacitance discharge time: <0.5s AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Open circuit test voltage: 4...8V Bandwidth for AC voltage measurements: 50...400Hz Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC Weight with battery: 550g Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC voltage; DC voltage; insulation resistance; resistance Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X |
auf Bestellung 75 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +4 |
FLUKE-1577 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Power supply: battery LR6 AA 1,5V x4 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover IP rating: IP40 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes AC current measuring range: 10µA...60mA; 400mA DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Dimensions (W x H x D): 100x203x50mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(1.2%+2 digit) AC current measuring accuracy: ±(2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V; 1kV Weight with battery: 550g Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +3 |
FLUKE-1587 FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+2 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Temperature measuring range: -40...537°C Continuity test: acoustic indication; <25Ω Weight with battery: 550g Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Illumination: yes Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Test voltage: 500V Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Optional equipment: FLK-C25 soft cover Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B Interface: Bluetooth IP rating: IP40 Diode test: 1mA @6V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C |
auf Bestellung 23 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-1587 T | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+2 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Temperature measuring range: -40...537°C Continuity test: acoustic indication; <25Ω Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Illumination: yes Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Test voltage: 50V; 100V Insulation resistance measuring ranges: 10kΩ...100MΩ Optional equipment: FLK-C25 soft cover IP rating: IP40 Diode test: 1mA @6V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +12 |
FLUKE-1587/MDT FC | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Related items: POM-5906A; POM-5907A; POM-6041B Type of measuring kit: multimeters Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +1 |
FLUKE-15B+/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Illumination: yes Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF AC current measuring range: 4A; 10A DC current measuring range: 4A; 10A AC voltage measuring range: 4V; 40V; 400V; 1kV DC voltage measuring range: 4V; 40V; 400V; 1kV Diode test: 2V Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ DC voltage measuring accuracy: ±(0.5% + 3 digit) Resistance measuring accuracy: ±(0.5%+2 digit) Dimensions (W x H x D): 183x91x49.5mm DC current measuring accuracy: ±(1.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(2%+ 5 digit) Standard equipment: test leads ( 2pcs.) Display parameters: (4000) Measuring instrument features: HOLD function; pocket size Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 |
auf Bestellung 77 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +4 |
FLUKE-175 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Continuity test: acoustic indication; <25Ω Weight with battery: 420g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery 6LR61 9V x1 Bargraph: 33 segm. 40x/s Capacitance measuring accuracy: ±(1.2%+ 2 digit) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Manufacturer series: Fluke 170 Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm |
auf Bestellung 62 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-177 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Continuity test: acoustic indication; <25Ω Weight with battery: 420g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery 6LR61 9V x1 Bargraph: 33 segm. 40x/s Capacitance measuring accuracy: ±(1.2%+ 2 digit) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Manufacturer series: Fluke 170 Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm |
auf Bestellung 62 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-1775 | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 280x190x62mm Manufacturer series: FLK-1770 IP rating: IP50 Operating temperature: -10...50°C Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: rechargeable battery Li-Ion x1 Kind of network: three-phase Dimensions: 280x190x62mm Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients Weight with battery: 2.1kg Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module Interface: Bluetooth; Ethernet; USB; WiFi Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Energy Analyze Plus |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
|
FLUKE-1775/FPC EU | FLUKE |
Category: Power Quality Analyzers Description: Meter: power quality logger; Network: three-phase; 280x190x62mm Manufacturer series: FLK-1770 IP rating: IP50 Operating temperature: -10...50°C Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: rechargeable battery Li-Ion x1 Kind of network: three-phase Dimensions: 280x190x62mm Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module Interface: Bluetooth; Ethernet; USB; WiFi Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Energy Analyze Plus |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +4 |
FLUKE-1777 | FLUKE |
Category: Power Quality AnalyzersDescription: Meter: power quality logger; Network: three-phase; 280x190x62mm Manufacturer series: FLK-1770 IP rating: IP50 Operating temperature: -10...50°C Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: rechargeable battery Li-Ion x1 Kind of network: three-phase Dimensions: 280x190x62mm Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients Weight with battery: 2.1kg Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module Interface: Bluetooth; Ethernet; USB; WiFi Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Energy Analyze Plus |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
|
FLUKE-1777/FPC EU | FLUKE |
Category: Power Quality Analyzers Description: Meter: power quality logger; Network: three-phase; 280x190x62mm Manufacturer series: FLK-1770 IP rating: IP50 Operating temperature: -10...50°C Type of meter: power quality logger Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Power supply: rechargeable battery Li-Ion x1 Kind of network: three-phase Dimensions: 280x190x62mm Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module Interface: Bluetooth; Ethernet; USB; WiFi Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Energy Analyze Plus |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +4 |
FLUKE-179 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Manufacturer series: Fluke 170 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Type of meter: digital multimeter Kind of display used: LCD True effective value measurement: True RMS AC Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Display parameters: 3,75 digit (6000) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 70 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-179 EGFID/TPAK/C25 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Temperature measuring range: -40...400°C Continuity test: acoustic indication; <25Ω Weight with battery: 420g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; soft case FLK-C25 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery 6LR61 9V x1 Bargraph: 33 segm. 40x/s Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Manufacturer series: Fluke 170 Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-179-2/IMSK | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Type of measuring kit: multimeters |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +9 |
FLUKE-179/EDA2/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Battery/ rechargeable battery: battery 6LR61 9V x1 Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip Related items: POM-5904A/POM; POM-6343; POM-7519A Type of meter: digital multimeter |
auf Bestellung 12 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +8 |
FLUKE-179/MAG2 KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Related items: POM-5904A/POM; POM-6343; POM-7519A Type of meter: digital multimeter |
auf Bestellung 69 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-17B+/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV; -55÷400°C Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Illumination: yes Temperature measuring range: -55...400°C Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF AC current measuring range: 4A; 10A DC current measuring range: 4A; 10A AC voltage measuring range: 4V; 40V; 400V; 1kV DC voltage measuring range: 4V; 40V; 400V; 1kV Diode test: 2V Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 50Hz; 500Hz; 5kHz; 10kHz; 50kHz Frequency measuring accuracy: ±(0.1%+3 digit) DC voltage measuring accuracy: ±(0.5% + 3 digit) Resistance measuring accuracy: ±(0.5%+2 digit) Dimensions (W x H x D): 183x91x49.5mm Temperature measurement accuracy: ±2% DC current measuring accuracy: ±(1.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(2%+ 5 digit) Standard equipment: K-type thermocouple; test leads ( 2pcs.) Display parameters: (4000) Measuring instrument features: HOLD function; pocket size Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 |
auf Bestellung 104 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-2052 | FLUKE |
Category: Metals & cables detectorsDescription: Non-contact voltage and cable detector; LCD 2,5",LED; IP40 Type of tester: non-contact voltage and cable detector Kind of display used: LCD 2,5"; LED IP rating: IP40 Conform to the norm: CAT IV 600V; EN 61010 Power supply: rechargeable battery Ni-MH AA 1,2V x12 Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12 Detected voltage range: 0...600V AC; 0...600V DC Transmitter dimensions: 183x93x50mm Receiver dimensions: 183x75x43mm Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air) |
auf Bestellung 17 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-2062 | FLUKE |
Category: Metals & cables detectorsDescription: Non-contact voltage and cable detector; LCD 3,5",LED; IP40 Type of tester: non-contact voltage and cable detector Kind of display used: LCD 3,5"; LED IP rating: IP40 Conform to the norm: CAT IV 600V; EN 61010 Power supply: rechargeable battery Ni-MH AA 1,2V x12 Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12 Detected voltage range: 0...600V AC; 0...600V DC Transmitter dimensions: 183x93x50mm Receiver dimensions: 277x112x65mm Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air) |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +2 |
FLUKE-279FC/IFLEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter with infrared camera; Bluetooth Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Type of meter: digital multimeter with infrared camera Connectors for the country: Europe; Great Britain Focusing: focus free Non-contact temperature measuring range: -10...200°C Capacitance measuring range: 1000nF...9999µF AC current measuring range: 100mA...999.9A; 2.5kA DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Diode test: 2V Resistance measuring range: 600Ω...50MΩ Frequency measuring range: 99.99...999.9Hz Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C Refresh rate: 8Hz Camera resolution: 80x60 Emissivity value: 0,95 (fixed) Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-27II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Kind of display used: LCD Type of meter: digital multimeter IP rating: IP67 Bargraph: 33 segm. 40x/s Illumination: yes Temperature measuring range: -200...1090°C Duty cycle factor: 0...99.9% Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @2.8V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Standard equipment: test leads Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-283FC/EUR | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52 Conform to the norm: CAT III 1500V; CAT IV 1000V Kind of display used: LCD Type of meter: digital multimeter IP rating: IP52 True effective value measurement: True RMS AC Illumination: yes Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.09% + 3 digit) Resistance measuring accuracy: ±(0.5%+4 digit) Dimensions (W x H x D): 225x105x57mm AC voltage measuring accuracy: ±(1% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Pollution degree: 2 Standard equipment: carrying case; FLK-TL175-HV test leads; magnetic strap Display parameters: (6000) Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-283FC/PV/EUR | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52 Conform to the norm: CAT III 1500V; CAT IV 1000V Kind of display used: LCD Type of meter: digital multimeter IP rating: IP52 True effective value measurement: True RMS AC Illumination: yes Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.09% + 3 digit) Resistance measuring accuracy: ±(0.5%+4 digit) Dimensions (W x H x D): 225x105x57mm AC voltage measuring accuracy: ±(1% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Pollution degree: 2 Standard equipment: carrying case; FLK-A283FC/EUR - current clamp; FLK-TL175-HV test leads; magnetic strap; test leads TL1000-MC4 Display parameters: (6000) Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-287/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C Display parameters: (50000) Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Power supply: battery LR6 AA 1,5V x6 Standard equipment: holder for probes; test leads FLK-TL71 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Manufacturer series: FLUKE 280 Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Software: Fluke Connect (FLK-IR3000FC) IP rating: IP54 Kind of display used: LCD TFT 2,2" True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) Conductance measurement: 10000000...50nS DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Weight with battery: 871g Display resolution: 320x240 Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Measurement memory: 10k Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 9 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +9 |
FLUKE-287/FVF/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Software: Fluke View Forms Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Type of meter: digital multimeter Software: Fluke View Forms Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +8 |
FLUKE-289/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C Display parameters: (50000) Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Power supply: battery LR6 AA 1,5V x6 Standard equipment: FLK-TL175 test leads; holder for probes Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Manufacturer series: FOX Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Software: Fluke Connect (FLK-IR3000FC) IP rating: IP54 Kind of display used: LCD TFT 2,2" True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) Conductance measurement: 10000000...50nS DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Weight with battery: 871g Display resolution: 320x240 Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Measurement memory: 10k Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 12 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +10 |
FLUKE-289/FVF/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Software: Fluke View Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Type of meter: digital multimeter Software: Fluke View Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +7 |
FLUKE-28II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Kind of display used: LCD Type of meter: digital multimeter IP rating: IP67 True effective value measurement: True RMS Bargraph: 33 segm. 40x/s Illumination: yes Temperature measuring range: -200...1090°C Duty cycle factor: 0...99.9% Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @2.8V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Standard equipment: test leads Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +5 |
FLUKE-28IIEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/19999) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring accuracy: ±(1% + 2 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Temperature measuring range: -200...1090°C Continuity test: acoustic indication Weight with battery: 517g Power supply: battery LR03 AAA 1,5V x3 Standard equipment: test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 Illumination: yes Bargraph: 33 segm. 40x/s Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA IP rating: IP67 Duty cycle factor: 0...99.9% Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-301D/EUR | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Conform to the norm: CAT III 300V Kind of display used: LCD Kind of meter: digital; pincers type Type of meter: multifunction IP rating: IP30 Illumination: yes Capacitance measuring range: 9.999pF; 99.99µF; 999.9µF AC current measuring range: 60A; 600A DC current measuring range: 60A; 600A AC voltage measuring range: 600V DC voltage measuring range: 600V Resistance measuring range: 600Ω; 6kΩ; 60kΩ Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Current measuring resolution: 10mA DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) Dimensions: 190x52x16mm DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(2%+ 5 digit) Bandwidth for AC voltage measurements: 45...400Hz Bandwidth for AC current measurements: 45...400Hz Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +1 |
FLUKE-302+/EUR | FLUKE |
Category: Meters and AC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; LCD; Øcable: 30mm Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Kind of meter: digital; pincers type Type of meter: multifunction Illumination: yes AC current measuring range: 400A AC voltage measuring range: 600V DC voltage measuring range: 600V Resistance measuring range: 0.4kΩ; 4kΩ DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1%+5 digit) Dimensions: 207x75x34mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(1.8% + 5 digit) Measuring instrument features: HOLD function Measurement: AC current; AC voltage; DC voltage; resistance Continuity test: acoustic indication; <70Ω Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 50 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +7 |
FLUKE-323 | FLUKE |
Category: Meters and AC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30 Display parameters: 3,5 digit Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; DC voltage; resistance Continuity test: acoustic indication; <70Ω Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Standard equipment: case; test leads Conform to the norm: CAT III 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A IP rating: IP30 Kind of display used: LCD True effective value measurement: True RMS AC current measuring range: 100mA...400A AC voltage measuring range: 100mV...400V; 600V Resistance measuring range: 100mΩ...400Ω; 4kΩ DC voltage measuring range: 100mV...400V; 600V Current measuring resolution: 0.1A DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1%+5 digit) Dimensions: 207x75x34mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Bandwidth for AC voltage measurements: 45...400Hz Bandwidth for AC current measurements: 45...400Hz Weight with battery: 265g Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator |
auf Bestellung 56 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +9 |
FLUKE-325 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Display parameters: 3,5 digit Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Standard equipment: case; test leads Conform to the norm: CAT III 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A IP rating: IP30 Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 10mA...40A; 400A AC current measuring range: 10mA...40A; 400A AC voltage measuring range: 100mV...400V; 600V Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ DC voltage measuring range: 100mV...400V; 600V Frequency measuring range: 5...500Hz Current measuring resolution: 10mA DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 207x75x34mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) Bandwidth for AC voltage measurements: 45...400Hz Bandwidth for AC current measurements: 45...400Hz Weight with battery: 283g Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator |
auf Bestellung 124 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +4 |
FLUKE-355 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 58mm; LCD Type of meter: multifunction Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance Kind of display used: LCD DC voltage measuring range: 4V; 40V; 400V; 1kV DC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring range: 4V; 40V; 400V; 750V; 1kV AC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring range: 40A; 400A; 2kA DC current measuring accuracy: ±(1.5% + 5 digit) AC current measuring range: 40A; 400A; 2kA AC current measuring accuracy: ±(1.5% + 5 digit) True effective value measurement: True RMS Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ Frequency measuring range: 5Hz; 100Hz; 1kHz Frequency measuring accuracy: ±(0.5%+5 digit) Resistance measuring accuracy: ±(1%+5 digit) Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x6 Standard equipment: crocodile clips; soft cover FLK-C43; test leads Related items: POM-5673B; POM-5907A; POM-6041B Measuring instrument features: HOLD function; MIN/MAX, MAX-MIN, MEAN function Weight without batteries: 814g Kind of meter: digital; pincers type Illumination: yes Max. diameter of measured cable: 58mm Dimensions: 300x98x52mm |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +9 |
FLUKE-374 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Connect Related items: POM-5913; POM-6173A; POM-7519A Kind of meter: digital; pincers type Type of meter: multifunction Test: diodes Kind of display used: LCD True effective value measurement: True RMS Illumination: yes Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 100mA...600A DC current measuring range: 100mA...600A DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Resistance measuring range: 100mΩ...600Ω; 6kΩ Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance |
auf Bestellung 9 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +9 |
FLUKE-375 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: Fluke Connect Related items: POM-5913; POM-6173A; POM-7519A Kind of meter: digital; pincers type Type of meter: multifunction Test: diodes Kind of display used: LCD True effective value measurement: True RMS Illumination: yes Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 100mA...600A DC current measuring range: 100mA...600A DC voltage measuring range: 100mV...1kV AC voltage measuring range: 0.1mV...1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +12 |
FLUKE-376 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Standard equipment: case; flexible current probe; FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5913; POM-6173A; POM-7519A Software: Fluke Connect Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 1...1000µF DC current measuring range: 100mA...1kA AC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...1kV Resistance measuring range: 0.1...60kΩ DC voltage measuring range: 0.1mV...1kV Frequency measuring range: 100mHz...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless |
auf Bestellung 37 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +10 |
FLUKE-381 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Power supply: battery LR03 AAA 1,5V x5 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5913; POM-6173A; POM-7519A Kind of display used: LCD Illumination: yes True effective value measurement: True RMS DC current measuring range: 100mA...1kA AC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC voltage measuring range: 100mV...600V; 1kV Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Body dimensions: 277x88x43mm DC voltage measuring accuracy: ±(1.5% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m) |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
| FLUKE-393-FC | Fluke | FLUKE-393-FC |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||
|
FLUKE-51-2 50HZ | FLUKE |
Category: Temperature MetersDescription: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: drop-like K-type probe; removable holster Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Kind of meter: digital Type of meter: temperature Kind of display used: LCD Illumination: yes Temperature measuring range (with T-type thermocouple): -250...400°C Temperature measuring range (with J-type thermocouple): -210...1200°C Temperature measuring range (with K-type thermocouple): -200...1372°C Temperature measuring range (with E-type thermocouple): -150...1000°C Temperature measurement resolution: 0.1°C Body dimensions: 173x86x38mm Weight with battery: 400g Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-51-2 60HZ | FLUKE |
Category: Temperature MetersDescription: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C Body dimensions: 173x86x38mm Kind of meter: digital Standard equipment: drop-like K-type probe; removable holster Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter Kind of display used: LCD Type of meter: temperature Illumination: yes Temperature measuring range (with T-type thermocouple): -250...400°C Temperature measuring range (with J-type thermocouple): -210...1200°C Temperature measuring range (with K-type thermocouple): -200...1372°C Temperature measuring range (with E-type thermocouple): -150...1000°C Temperature measurement resolution: 0.1°C Weight with battery: 400g Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
|
FLUKE-52-2 50HZ | FLUKE |
Category: Temperature MetersDescription: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: drop-like K-type probe x2; removable holster Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Kind of meter: digital Type of meter: temperature Kind of display used: LCD Illumination: yes Temperature measuring range (with T-type thermocouple): -250...400°C Temperature measuring range (with J-type thermocouple): -210...1200°C Temperature measuring range (with K-type thermocouple): -200...1372°C Temperature measuring range (with E-type thermocouple): -150...1000°C Temperature measurement resolution: 0.1°C Body dimensions: 173x86x38mm Weight with battery: 400g Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-52-2 60HZ | FLUKE |
Category: Temperature MetersDescription: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C Body dimensions: 173x86x38mm Kind of meter: digital Standard equipment: drop-like K-type probe x2; removable holster Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter Kind of display used: LCD Type of meter: temperature Illumination: yes Temperature measuring range (with T-type thermocouple): -250...400°C Temperature measuring range (with J-type thermocouple): -210...1200°C Temperature measuring range (with K-type thermocouple): -200...1372°C Temperature measuring range (with E-type thermocouple): -150...1000°C Temperature measurement resolution: 0.1°C Weight with battery: 400g Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
|
FLUKE-53-2 B 60HZ | FLUKE |
Category: Temperature MetersDescription: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C Body dimensions: 173x86x38mm Kind of meter: digital Standard equipment: drop-like K-type probe; removable holster Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter Interface: IrDA Kind of display used: LCD Type of meter: temperature Illumination: yes Temperature measuring range (with T-type thermocouple): -250...400°C Temperature measuring range (with J-type thermocouple): -210...1200°C Temperature measuring range with N-type thermocouple: -200...1300°C Temperature measuring range (with K-type thermocouple): -200...1372°C Temperature measuring range (with E-type thermocouple): -150...1000°C Temperature measuring range (with R-type thermocouple): 0...1767°C Temperature measuring range (with S-type thermocouple): 0...1767°C Temperature measurement resolution: 0.1°C Weight with battery: 400g Measurement memory: 500 Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E, N, R, S; real time clock; single channel temperature measurement; thermocouple errors compensation Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +2 |
FLUKE-64 MAX | FLUKE |
Category: PirometersDescription: Infrared thermometer; LCD; -30÷600°C; Accur.(IR): ±(1%+1°C); IP54 Type of meter: infrared thermometer Kind of display used: LCD Measurement: non-contact temeprature (IR) Power supply: battery LR6 AA 1,5V x1 Measuring instrument features: automatic power-off; data logger function; laser sight; long operating time up to 30 hours; MIN/MAX/DIF/AVG function; white LED torch Body dimensions: 175x85x75mm Battery/ rechargeable battery: battery LR6 AA 1,5V x1 Illumination: yes Non-contact temperature measuring range: -30...600°C Non-contact temperature measuring resolution: 0.1°C Response time: <0.5s Non-contact temperature measuring accuracy: ±(1% + 1°C) Optical resolution: 20:1 Producer guarantee (months): 36 Weight with battery: 255g Emissivity value: 0,1...1 Measuring unit: °C; °F Resistance to: fall from 3m height IP rating: IP54 |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() +2 |
FLUKE-705 | FLUKE |
Category: CalibratorsDescription: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA Measurement: DC current; DC voltage Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221 Kind of display used: LCD Kind of calibrator: loop Type of meter: calibrator Power supply: battery 6F22 9V x1 Current source accuracy: ±(0,025% + 2 digits) Current source: 0...20mA; 4...20mA DC current measuring range: 0.001...24mA DC voltage measuring range: 1mV...28V DC voltage measuring accuracy: ±(0.025% + 1 digit) DC current measuring accuracy: ±(0.025% + 2 digit) Dimensions: 201x98x52mm Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||
![]() +1 |
FLUKE-707 | FLUKE |
Category: CalibratorsDescription: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate Power supply: battery 6F22 9V x1 Type of meter: calibrator Kind of display used: LCD Kind of calibrator: loop Current source: 0...20mA; 4...20mA DC current measuring range: 0.001...24mA DC voltage measuring range: 1mV...28V DC current measuring accuracy: ±(0.015% + 2 digit) DC voltage measuring accuracy: ±(0.015% + 2 digit) Dimensions: 159x77x55mm Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; additionally protection of voltage output; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; HART range with loop and built-in 250Ω resistor; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221 Current source accuracy: ±(0,015% + 2 digits) Measurement: DC current; DC voltage |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
| FLUKE-115 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Standard equipment: FLK-TL75 test leads
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Dimensions (W x H x D): 84x167x46mm
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Related items: POM-5543B; POM-6275; POM-6343
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Standard equipment: FLK-TL75 test leads
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Dimensions (W x H x D): 84x167x46mm
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Related items: POM-5543B; POM-6275; POM-6343
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
auf Bestellung 117 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 303.73 EUR |
| FLUKE-116 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
DC current measuring range: 0.1...600µA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
DC current measuring range: 0.1...600µA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Standard equipment: FLK-TL75 test leads
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
auf Bestellung 25 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 415.01 EUR |
| FLUKE-116/323 KIT |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Type of measuring kit: multimeters
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Type of measuring kit: multimeters
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 602.37 EUR |
| FLUKE-117 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
auf Bestellung 78 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 418.1 EUR |
| FLUKE-117/323 EUR |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 573.42 EUR |
| FLUKE-123B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-123B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Type of oscilloscope: scopemeter
Band: 20MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 20n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-124B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-124B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Related items: POM-72941; POM-72942
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4183.61 EUR |
| FLUKE-125B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-125B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Type of oscilloscope: scopemeter
Band: 40MHz
Kind of display used: colour; LCD TFT 5,7"
Number of channels: 2
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Sampling: 40Msps
Time base: 10n...60s/div
Display resolution: 640x480
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Resistance measuring accuracy: ±(0.6%+5 digit)
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Dimensions: 259x132x55mm
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
IP rating: IP51
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Manufacturer series: FLUKE 120B
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Software: Fluke View
Connectors for the country: Europe
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-1503 |
![]() |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Type of meter: insulation resistance
Related items: POM-5674C; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Automatic discharging capacitance: max. 1µF
DC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Body dimensions: 203x100x50mm
Capacitance discharge time: <0.5s
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Open circuit test voltage: 4...8V
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Type of meter: insulation resistance
Related items: POM-5674C; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Automatic discharging capacitance: max. 1µF
DC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Body dimensions: 203x100x50mm
Capacitance discharge time: <0.5s
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Open circuit test voltage: 4...8V
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 667.61 EUR |
| FLUKE-1507 |
![]() |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Type of meter: insulation resistance
Related items: POM-5674C; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Automatic discharging capacitance: max. 1µF
DC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Body dimensions: 203x100x50mm
Capacitance discharge time: <0.5s
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Open circuit test voltage: 4...8V
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Type of meter: insulation resistance
Related items: POM-5674C; POM-5907A; POM-6041B
IP rating: IP40
Kind of display used: LCD
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
Automatic discharging capacitance: max. 1µF
DC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Body dimensions: 203x100x50mm
Capacitance discharge time: <0.5s
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Open circuit test voltage: 4...8V
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
auf Bestellung 75 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 844.76 EUR |
| FLUKE-1577 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1101.66 EUR |
| FLUKE-1587 FC |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
Weight with battery: 550g
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Optional equipment: FLK-C25 soft cover
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Interface: Bluetooth
IP rating: IP40
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
Weight with battery: 550g
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Optional equipment: FLK-C25 soft cover
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Interface: Bluetooth
IP rating: IP40
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
auf Bestellung 23 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1308.61 EUR |
| FLUKE-1587 T |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...537°C
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1217.19 EUR |
| FLUKE-1587/MDT FC |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Type of measuring kit: multimeters
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Type of measuring kit: multimeters
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-15B+/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Illumination: yes
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
AC current measuring range: 4A; 10A
DC current measuring range: 4A; 10A
AC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring range: 4V; 40V; 400V; 1kV
Diode test: 2V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 3 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Dimensions (W x H x D): 183x91x49.5mm
DC current measuring accuracy: ±(1.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Standard equipment: test leads ( 2pcs.)
Display parameters: (4000)
Measuring instrument features: HOLD function; pocket size
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Illumination: yes
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
AC current measuring range: 4A; 10A
DC current measuring range: 4A; 10A
AC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring range: 4V; 40V; 400V; 1kV
Diode test: 2V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 3 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Dimensions (W x H x D): 183x91x49.5mm
DC current measuring accuracy: ±(1.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Standard equipment: test leads ( 2pcs.)
Display parameters: (4000)
Measuring instrument features: HOLD function; pocket size
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; resistance
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
auf Bestellung 77 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 144.14 EUR |
| FLUKE-175 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
auf Bestellung 62 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 437.05 EUR |
| FLUKE-177 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
auf Bestellung 62 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 514.66 EUR |
| FLUKE-1775 |
![]() |
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Weight with battery: 2.1kg
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Weight with battery: 2.1kg
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-1775/FPC EU |
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; case; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-1777 |
![]() |
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Weight with battery: 2.1kg
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Weight with battery: 2.1kg
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-1777/FPC EU |
Hersteller: FLUKE
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Category: Power Quality Analyzers
Description: Meter: power quality logger; Network: three-phase; 280x190x62mm
Manufacturer series: FLK-1770
IP rating: IP50
Operating temperature: -10...50°C
Type of meter: power quality logger
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Power supply: rechargeable battery Li-Ion x1
Kind of network: three-phase
Dimensions: 280x190x62mm
Measurement: AC current; active electric energy; active power; AC voltage; apparent electric energy; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; reactive electric energy; reactive power; transients
Standard equipment: adapter for main socket FLK-174X-MA-C8; cable markers; crocodile clip, black FLK-AC285 x4; crocodile clip, green FLK-AC285; FLK-i17XX-FLEX1500 - current clamp x4; Fluke Premium Care- 1 year; hard case; magnetic hanging strap; manufacturer's calibration certificate; MP1 magnet probe (3 red and 1 black); test lead; test lead 3-phase + N; test leads set FLK-17XX 0,18M; WiFi and Bluetooth module
Interface: Bluetooth; Ethernet; USB; WiFi
Measuring instrument features: built- in report generator; memory built-in; transfer measurement data wireless
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Energy Analyze Plus
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-179 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 70 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 611.75 EUR |
| FLUKE-179 EGFID/TPAK/C25 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...400°C
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; soft case FLK-C25
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Temperature measuring range: -40...400°C
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; soft case FLK-C25
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 638.52 EUR |
| FLUKE-179-2/IMSK |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of measuring kit: multimeters
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of measuring kit: multimeters
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 783.15 EUR |
| FLUKE-179/EDA2/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
auf Bestellung 12 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 695.85 EUR |
| FLUKE-179/MAG2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Type of meter: digital multimeter
auf Bestellung 69 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 581.55 EUR |
| FLUKE-17B+/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV; -55÷400°C
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Illumination: yes
Temperature measuring range: -55...400°C
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
AC current measuring range: 4A; 10A
DC current measuring range: 4A; 10A
AC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring range: 4V; 40V; 400V; 1kV
Diode test: 2V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 50Hz; 500Hz; 5kHz; 10kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+3 digit)
DC voltage measuring accuracy: ±(0.5% + 3 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Dimensions (W x H x D): 183x91x49.5mm
Temperature measurement accuracy: ±2%
DC current measuring accuracy: ±(1.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Standard equipment: K-type thermocouple; test leads ( 2pcs.)
Display parameters: (4000)
Measuring instrument features: HOLD function; pocket size
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (4000); VDC: 4V,40V,400V,1kV; -55÷400°C
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Illumination: yes
Temperature measuring range: -55...400°C
Capacitance measuring range: 40nF; 400nF; 4µF; 40µF; 400µF; 1mF
AC current measuring range: 4A; 10A
DC current measuring range: 4A; 10A
AC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring range: 4V; 40V; 400V; 1kV
Diode test: 2V
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 50Hz; 500Hz; 5kHz; 10kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+3 digit)
DC voltage measuring accuracy: ±(0.5% + 3 digit)
Resistance measuring accuracy: ±(0.5%+2 digit)
Dimensions (W x H x D): 183x91x49.5mm
Temperature measurement accuracy: ±2%
DC current measuring accuracy: ±(1.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Standard equipment: K-type thermocouple; test leads ( 2pcs.)
Display parameters: (4000)
Measuring instrument features: HOLD function; pocket size
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
auf Bestellung 104 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 192.19 EUR |
| FLUKE-2052 |
![]() |
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact voltage and cable detector; LCD 2,5",LED; IP40
Type of tester: non-contact voltage and cable detector
Kind of display used: LCD 2,5"; LED
IP rating: IP40
Conform to the norm: CAT IV 600V; EN 61010
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Detected voltage range: 0...600V AC; 0...600V DC
Transmitter dimensions: 183x93x50mm
Receiver dimensions: 183x75x43mm
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Category: Metals & cables detectors
Description: Non-contact voltage and cable detector; LCD 2,5",LED; IP40
Type of tester: non-contact voltage and cable detector
Kind of display used: LCD 2,5"; LED
IP rating: IP40
Conform to the norm: CAT IV 600V; EN 61010
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Detected voltage range: 0...600V AC; 0...600V DC
Transmitter dimensions: 183x93x50mm
Receiver dimensions: 183x75x43mm
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
auf Bestellung 17 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1537.71 EUR |
| FLUKE-2062 |
![]() |
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact voltage and cable detector; LCD 3,5",LED; IP40
Type of tester: non-contact voltage and cable detector
Kind of display used: LCD 3,5"; LED
IP rating: IP40
Conform to the norm: CAT IV 600V; EN 61010
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Detected voltage range: 0...600V AC; 0...600V DC
Transmitter dimensions: 183x93x50mm
Receiver dimensions: 277x112x65mm
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Category: Metals & cables detectors
Description: Non-contact voltage and cable detector; LCD 3,5",LED; IP40
Type of tester: non-contact voltage and cable detector
Kind of display used: LCD 3,5"; LED
IP rating: IP40
Conform to the norm: CAT IV 600V; EN 61010
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Detected voltage range: 0...600V AC; 0...600V DC
Transmitter dimensions: 183x93x50mm
Receiver dimensions: 277x112x65mm
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 3121.18 EUR |
| FLUKE-279FC/IFLEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω...50MΩ
Frequency measuring range: 99.99...999.9Hz
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω...50MΩ
Frequency measuring range: 99.99...999.9Hz
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1692 EUR |
| FLUKE-27II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP67
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
Duty cycle factor: 0...99.9%
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @2.8V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Standard equipment: test leads
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP67
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
Duty cycle factor: 0...99.9%
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @2.8V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Standard equipment: test leads
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1011.75 EUR |
| FLUKE-283FC/EUR |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52
Conform to the norm: CAT III 1500V; CAT IV 1000V
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP52
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF
AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.09% + 3 digit)
Resistance measuring accuracy: ±(0.5%+4 digit)
Dimensions (W x H x D): 225x105x57mm
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Pollution degree: 2
Standard equipment: carrying case; FLK-TL175-HV test leads; magnetic strap
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52
Conform to the norm: CAT III 1500V; CAT IV 1000V
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP52
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF
AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.09% + 3 digit)
Resistance measuring accuracy: ±(0.5%+4 digit)
Dimensions (W x H x D): 225x105x57mm
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Pollution degree: 2
Standard equipment: carrying case; FLK-TL175-HV test leads; magnetic strap
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 753.12 EUR |
| FLUKE-283FC/PV/EUR |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52
Conform to the norm: CAT III 1500V; CAT IV 1000V
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP52
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF
AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.09% + 3 digit)
Resistance measuring accuracy: ±(0.5%+4 digit)
Dimensions (W x H x D): 225x105x57mm
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Pollution degree: 2
Standard equipment: carrying case; FLK-A283FC/EUR - current clamp; FLK-TL175-HV test leads; magnetic strap; test leads TL1000-MC4
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(1%+3digit); IP52
Conform to the norm: CAT III 1500V; CAT IV 1000V
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP52
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.01...1000nF; 10µF; 100µF; 9.999mF
AC voltage measuring range: 0.1...6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...6V; 60V; 600V; 1.5kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.09% + 3 digit)
Resistance measuring accuracy: ±(0.5%+4 digit)
Dimensions (W x H x D): 225x105x57mm
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Pollution degree: 2
Standard equipment: carrying case; FLK-A283FC/EUR - current clamp; FLK-TL175-HV test leads; magnetic strap; test leads TL1000-MC4
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX, MAX-MIN, MEAN function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1149.38 EUR |
| FLUKE-287/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Display parameters: (50000)
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Power supply: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: FLUKE 280
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Display parameters: (50000)
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Power supply: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: FLUKE 280
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1186.67 EUR |
| FLUKE-287/FVF/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Type of meter: digital multimeter
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Type of meter: digital multimeter
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1416.31 EUR |
| FLUKE-289/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Display parameters: (50000)
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Power supply: battery LR6 AA 1,5V x6
Standard equipment: FLK-TL175 test leads; holder for probes
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: FOX
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Display parameters: (50000)
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Power supply: battery LR6 AA 1,5V x6
Standard equipment: FLK-TL175 test leads; holder for probes
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: FOX
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
auf Bestellung 12 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1301.8 EUR |
| FLUKE-289/FVF/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Type of meter: digital multimeter
Software: Fluke View
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Type of meter: digital multimeter
Software: Fluke View
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1461 EUR |
| FLUKE-28II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP67
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
Duty cycle factor: 0...99.9%
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @2.8V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Standard equipment: test leads
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Kind of display used: LCD
Type of meter: digital multimeter
IP rating: IP67
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
Duty cycle factor: 0...99.9%
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @2.8V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Standard equipment: test leads
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1011.75 EUR |
| FLUKE-28IIEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Temperature measuring range: -200...1090°C
Continuity test: acoustic indication
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
IP rating: IP67
Duty cycle factor: 0...99.9%
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Temperature measuring range: -200...1090°C
Continuity test: acoustic indication
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
IP rating: IP67
Duty cycle factor: 0...99.9%
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2424.36 EUR |
| FLUKE-301D/EUR |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Conform to the norm: CAT III 300V
Kind of display used: LCD
Kind of meter: digital; pincers type
Type of meter: multifunction
IP rating: IP30
Illumination: yes
Capacitance measuring range: 9.999pF; 99.99µF; 999.9µF
AC current measuring range: 60A; 600A
DC current measuring range: 60A; 600A
AC voltage measuring range: 600V
DC voltage measuring range: 600V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 190x52x16mm
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Conform to the norm: CAT III 300V
Kind of display used: LCD
Kind of meter: digital; pincers type
Type of meter: multifunction
IP rating: IP30
Illumination: yes
Capacitance measuring range: 9.999pF; 99.99µF; 999.9µF
AC current measuring range: 60A; 600A
DC current measuring range: 60A; 600A
AC voltage measuring range: 600V
DC voltage measuring range: 600V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 190x52x16mm
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 166.45 EUR |
| FLUKE-302+/EUR |
![]() |
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; Øcable: 30mm
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
Type of meter: multifunction
Illumination: yes
AC current measuring range: 400A
AC voltage measuring range: 600V
DC voltage measuring range: 600V
Resistance measuring range: 0.4kΩ; 4kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(1.8% + 5 digit)
Measuring instrument features: HOLD function
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; Øcable: 30mm
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
Type of meter: multifunction
Illumination: yes
AC current measuring range: 400A
AC voltage measuring range: 600V
DC voltage measuring range: 600V
Resistance measuring range: 0.4kΩ; 4kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(1.8% + 5 digit)
Measuring instrument features: HOLD function
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 50 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 133.85 EUR |
| FLUKE-323 |
![]() |
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
auf Bestellung 56 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 209.9 EUR |
| FLUKE-325 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC voltage measurements: 45...400Hz
Bandwidth for AC current measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
auf Bestellung 124 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 364.09 EUR |
| FLUKE-355 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 58mm; LCD
Type of meter: multifunction
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of display used: LCD
DC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 4V; 40V; 400V; 750V; 1kV
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 40A; 400A; 2kA
DC current measuring accuracy: ±(1.5% + 5 digit)
AC current measuring range: 40A; 400A; 2kA
AC current measuring accuracy: ±(1.5% + 5 digit)
True effective value measurement: True RMS
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ
Frequency measuring range: 5Hz; 100Hz; 1kHz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x6
Standard equipment: crocodile clips; soft cover FLK-C43; test leads
Related items: POM-5673B; POM-5907A; POM-6041B
Measuring instrument features: HOLD function; MIN/MAX, MAX-MIN, MEAN function
Weight without batteries: 814g
Kind of meter: digital; pincers type
Illumination: yes
Max. diameter of measured cable: 58mm
Dimensions: 300x98x52mm
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 58mm; LCD
Type of meter: multifunction
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Kind of display used: LCD
DC voltage measuring range: 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 4V; 40V; 400V; 750V; 1kV
AC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring range: 40A; 400A; 2kA
DC current measuring accuracy: ±(1.5% + 5 digit)
AC current measuring range: 40A; 400A; 2kA
AC current measuring accuracy: ±(1.5% + 5 digit)
True effective value measurement: True RMS
Resistance measuring range: 0.4kΩ; 4kΩ; 40kΩ; 400kΩ
Frequency measuring range: 5Hz; 100Hz; 1kHz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x6
Standard equipment: crocodile clips; soft cover FLK-C43; test leads
Related items: POM-5673B; POM-5907A; POM-6041B
Measuring instrument features: HOLD function; MIN/MAX, MAX-MIN, MEAN function
Weight without batteries: 814g
Kind of meter: digital; pincers type
Illumination: yes
Max. diameter of measured cable: 58mm
Dimensions: 300x98x52mm
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1384.98 EUR |
| FLUKE-374 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
Related items: POM-5913; POM-6173A; POM-7519A
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
Related items: POM-5913; POM-6173A; POM-7519A
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 670.24 EUR |
| FLUKE-375 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
Related items: POM-5913; POM-6173A; POM-7519A
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: Fluke Connect
Related items: POM-5913; POM-6173A; POM-7519A
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 785.93 EUR |
| FLUKE-376 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
auf Bestellung 37 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 781.14 EUR |
| FLUKE-381 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1051.22 EUR |
| FLUKE-393-FC |
Hersteller: Fluke
FLUKE-393-FC
FLUKE-393-FC
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1215.67 EUR |
| 2+ | 1117.27 EUR |
| FLUKE-51-2 50HZ |
![]() |
Hersteller: FLUKE
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: drop-like K-type probe; removable holster
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of meter: digital
Type of meter: temperature
Kind of display used: LCD
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Body dimensions: 173x86x38mm
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: drop-like K-type probe; removable holster
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of meter: digital
Type of meter: temperature
Kind of display used: LCD
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Body dimensions: 173x86x38mm
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 605.91 EUR |
| FLUKE-51-2 60HZ |
![]() |
Hersteller: FLUKE
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; single channel temperature measurement; thermocouple errors compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-52-2 50HZ |
![]() |
Hersteller: FLUKE
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: drop-like K-type probe x2; removable holster
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of meter: digital
Type of meter: temperature
Kind of display used: LCD
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Body dimensions: 173x86x38mm
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: drop-like K-type probe x2; removable holster
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Kind of meter: digital
Type of meter: temperature
Kind of display used: LCD
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Body dimensions: 173x86x38mm
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 768.84 EUR |
| FLUKE-52-2 60HZ |
![]() |
Hersteller: FLUKE
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe x2; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe x2; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E; T1-T2 function; thermocouple errors compensation; two channel temperature measurement
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-53-2 B 60HZ |
![]() |
Hersteller: FLUKE
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Interface: IrDA
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measurement memory: 500
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E, N, R, S; real time clock; single channel temperature measurement; thermocouple errors compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Category: Temperature Meters
Description: Meter: temperature; digital; LCD; -200÷1372°C; Resol: 0.1°C
Body dimensions: 173x86x38mm
Kind of meter: digital
Standard equipment: drop-like K-type probe; removable holster
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Optional equipment: FLK-80PK-1 drop-like K-type probe; FLK-80PK-22 drop-like K-type probe; FLK-80PK-24 drop-like K-type probe; FLK-80PK-25 drop-like K-type probe; FLK-80PK-26 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C25 soft cover; FLK-TOOLPAK strap with magnet for suspending the meter
Interface: IrDA
Kind of display used: LCD
Type of meter: temperature
Illumination: yes
Temperature measuring range (with T-type thermocouple): -250...400°C
Temperature measuring range (with J-type thermocouple): -210...1200°C
Temperature measuring range with N-type thermocouple: -200...1300°C
Temperature measuring range (with K-type thermocouple): -200...1372°C
Temperature measuring range (with E-type thermocouple): -150...1000°C
Temperature measuring range (with R-type thermocouple): 0...1767°C
Temperature measuring range (with S-type thermocouple): 0...1767°C
Temperature measurement resolution: 0.1°C
Weight with battery: 400g
Measurement memory: 500
Measuring instrument features: automatic power-off; MIN/MAX/MEDIUM function; operates with thermocouple types: J, K, T, E, N, R, S; real time clock; single channel temperature measurement; thermocouple errors compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-64 MAX |
![]() |
Hersteller: FLUKE
Category: Pirometers
Description: Infrared thermometer; LCD; -30÷600°C; Accur.(IR): ±(1%+1°C); IP54
Type of meter: infrared thermometer
Kind of display used: LCD
Measurement: non-contact temeprature (IR)
Power supply: battery LR6 AA 1,5V x1
Measuring instrument features: automatic power-off; data logger function; laser sight; long operating time up to 30 hours; MIN/MAX/DIF/AVG function; white LED torch
Body dimensions: 175x85x75mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x1
Illumination: yes
Non-contact temperature measuring range: -30...600°C
Non-contact temperature measuring resolution: 0.1°C
Response time: <0.5s
Non-contact temperature measuring accuracy: ±(1% + 1°C)
Optical resolution: 20:1
Producer guarantee (months): 36
Weight with battery: 255g
Emissivity value: 0,1...1
Measuring unit: °C; °F
Resistance to: fall from 3m height
IP rating: IP54
Category: Pirometers
Description: Infrared thermometer; LCD; -30÷600°C; Accur.(IR): ±(1%+1°C); IP54
Type of meter: infrared thermometer
Kind of display used: LCD
Measurement: non-contact temeprature (IR)
Power supply: battery LR6 AA 1,5V x1
Measuring instrument features: automatic power-off; data logger function; laser sight; long operating time up to 30 hours; MIN/MAX/DIF/AVG function; white LED torch
Body dimensions: 175x85x75mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x1
Illumination: yes
Non-contact temperature measuring range: -30...600°C
Non-contact temperature measuring resolution: 0.1°C
Response time: <0.5s
Non-contact temperature measuring accuracy: ±(1% + 1°C)
Optical resolution: 20:1
Producer guarantee (months): 36
Weight with battery: 255g
Emissivity value: 0,1...1
Measuring unit: °C; °F
Resistance to: fall from 3m height
IP rating: IP54
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 248.05 EUR |
| FLUKE-705 |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-707 |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Power supply: battery 6F22 9V x1
Type of meter: calibrator
Kind of display used: LCD
Kind of calibrator: loop
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC current measuring accuracy: ±(0.015% + 2 digit)
DC voltage measuring accuracy: ±(0.015% + 2 digit)
Dimensions: 159x77x55mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; additionally protection of voltage output; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; HART range with loop and built-in 250Ω resistor; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Current source accuracy: ±(0,015% + 2 digits)
Measurement: DC current; DC voltage
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Power supply: battery 6F22 9V x1
Type of meter: calibrator
Kind of display used: LCD
Kind of calibrator: loop
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC current measuring accuracy: ±(0.015% + 2 digit)
DC voltage measuring accuracy: ±(0.015% + 2 digit)
Dimensions: 159x77x55mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; additionally protection of voltage output; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; HART range with loop and built-in 250Ω resistor; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Current source accuracy: ±(0,015% + 2 digits)
Measurement: DC current; DC voltage
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1638.34 EUR |