Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
||
---|---|---|---|---|---|---|---|
![]() |
PLS 6G RBP KIT | FLUKE |
![]() ![]() Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 12h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; green laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() |
PLS 6G RBP SYS | FLUKE |
![]() ![]() Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 12h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; green laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() |
PLS 6R RBP KIT | FLUKE |
![]() ![]() Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 30h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; red laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +8 |
FLK-393FC-PVLEAD | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV Max. diameter of measured cable: 34mm Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010 Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4 Kind of meter: digital; pincers type Software: Fluke Connect Kind of display used: LCD Type of meter: multifunction True effective value measurement: True RMS Illumination: yes Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 100mA...999.9A AC current measuring range: 100mA...999.9A Dimensions: 281x84x49mm Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) Pollution degree: 2 AC current measuring accuracy: ±(2% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) Frequency measuring range: 5...500Hz Weight with battery: 520g AC voltage measuring range: 600V; 1kV DC voltage measuring range: 600V; 1.5kV Resistance measuring range: 600Ω; 6kΩ; 60kΩ CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA Continuity test: acoustic indication; <30Ω Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Interface: Bluetooth |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
FLK-393-IRR-PVLEAD | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010 Software: Fluke Connect Kind of meter: digital; pincers type Kind of display used: LCD True effective value measurement: True RMS Illumination: yes DC current measuring range: 100mA...999.9A AC current measuring range: 100mA...999.9A AC voltage measuring range: 600V; 1kV DC voltage measuring range: 600V; 1.5kV Capacitance measuring range: 0.1...100µF; 1mF Frequency measuring accuracy: ±(0.5%+5 digit) Frequency measuring range: 5...500Hz Max. diameter of measured cable: 34mm DC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring range: 600Ω; 6kΩ; 60kΩ Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 281x84x49mm AC voltage measuring accuracy: ±(1% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) Pollution degree: 2 Weight with battery: 520g CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4 Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance Continuity test: acoustic indication; <30Ω Type of meter: multifunction Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
TI-CAR CHARGER | FLUKE |
Category: Fluke Infrared Cameras Description: Test acces: car charger Type of test accessories: car charger Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() |
FLK-TI-SBP3 | FLUKE |
![]() ![]() Description: Test acces: accu pack; 2.5h; 7.4V Type of test accessories: accu pack Related items: FLK-TI32; FLK-TIR32 Body dimensions: 124x58.4x42.4mm Charge time: 2.5h Rated voltage: 7.4V |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() |
FLK-TI-TRIPOD2 | FLUKE |
![]() Description: Test acces: stand mount Type of test accessories: stand mount Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +5 |
FLUKE-287/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54 Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Standard equipment: holder for probes; test leads FLK-TL71 Kind of display used: colour; LCD TFT 2,2" Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Software: Fluke Connect (FLK-IR3000FC) IP rating: IP54 True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) Conductance measurement: 10000000...50nS DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Display resolution: 320x240 Weight with battery: 871g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Measurement memory: 10k Display parameters: (50000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Manufacturer series: FLUKE 280 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 13 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +8 |
FLUKE-289/EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Standard equipment: FLK-TL175 test leads; holder for probes Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function Type of meter: digital multimeter Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 2,2" Software: Fluke Connect (FLK-IR3000FC) Manufacturer series: FOX IP rating: IP54 True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF Conductance measurement: 10000000...50nS AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Weight with battery: 871g Display resolution: 320x240 Measurement memory: 10k Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (50000) |
auf Bestellung 21 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLK-TIS20+ MAX 9HZ | FLUKE |
![]() Description: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 120x90 Temperature measuring range: -20...400°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 50° horizontal x 38° vertical IP rating: IP54 Power supply: rechargeable battery Li-Ion x1 Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC Standard equipment: battery charger; case; power supply; USB cable Thermal sensitivity (NETD): 60mK Interface: USB; WiFi Resistance to: fall from 2m height Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Display resolution: 320x240 Three-dimensional resolution: 7.6mrad Dimensions: 26.7x10.1x14.5mm Measurement: temperature Focusing: FocusFree Measuring unit: °C; °F |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-114 EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Related items: POM-5673B; POM-5900A/POM; POM-7519A Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 110 True effective value measurement: True RMS AC DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring accuracy: ±(0.5% + 2 digit) Dimensions (W x H x D): 84x167x46mm Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222 Measurement: AC voltage; DC voltage; resistance Continuity test: acoustic indication; <20Ω |
auf Bestellung 9 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-116 EUR | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Measuring instruments application: air conditioning; heating industry; ventilation Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Temperature measuring range: -40...400°C DC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) Dimensions (W x H x D): 84x167x46mm Temperature measurement accuracy: ±(0.1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Continuity test: acoustic indication; <20Ω |
auf Bestellung 30 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-117 EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Related items: POM-5673B; POM-5900A/POM; POM-7519A Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 110 True effective value measurement: True RMS AC DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 1mA...6A; 10A; (20A <30s) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) Dimensions (W x H x D): 84x167x46mm Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω |
auf Bestellung 41 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-175 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 170 True effective value measurement: True RMS AC DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz DC voltage measuring accuracy: ±(0.15% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) Dimensions (W x H x D): 89x190x45mm Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Display parameters: 3,75 digit (6000) Standard equipment: FLK-TL75 test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <25Ω |
auf Bestellung 96 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-177 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 170 True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Display parameters: 3,75 digit (6000) |
auf Bestellung 92 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-179 EGFID | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 170 True effective value measurement: True RMS AC Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Display parameters: 3,75 digit (6000) |
auf Bestellung 113 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-1577 | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover IP rating: IP40 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes AC current measuring range: 10µA...60mA; 400mA DC current measuring range: 10µA...60mA; 400mA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Dimensions (W x H x D): 100x203x50mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(1.2%+2 digit) AC current measuring accuracy: ±(2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V; 1kV Weight with battery: 550g Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
2824477 | FLUKE |
Category: Accessories - Others Description: Battery container Related items: FLK-289 Type of test accessories: battery container |
auf Bestellung 16 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLK-3000FC/EDA2 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910 Type of meter: digital multimeter Related items: POM-5677B; POM-5899A; POM-7519A |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-179/EDA2/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A Battery/ rechargeable battery: battery 6LR61 9V x1 Type of meter: digital multimeter Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +8 |
FLUKE-179/MAG2 KIT | FLUKE |
![]() ![]() Description: Digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Type of meter: digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE-T110 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 12...690V AC Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 42 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE T110/VDE | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-T90 | FLUKE |
![]() Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ Type of tester: electrical Kind of display used: LEDs Measurement: AC voltage; DC voltage Phase-to-phase voltage range for phase sequence indication: 12...690V AC AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Bandwidth for AC voltage measurements: 0...400Hz DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V DC voltage measuring accuracy: ±(3% + 5 digit) Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Additional functions: illumination lamp IP rating: IP54 Conform to the norm: CAT II 690V; CAT III 600V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator Body dimensions: 245x64x28mm Weight with battery: 180g Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE-T130 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 36 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE T130/VDE | FLUKE |
![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LCD; LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Display parameters: 3,5 digit Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 13 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE-T150 | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Resistance measuring range: 1...1999Ω Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage; resistance Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 112 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE T150/VDE | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Resistance measuring range: 1...1999Ω Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 100...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage; resistance Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 52 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-787B | FLUKE |
![]() ![]() Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Related items: POM-5900A/POM; POM-6173A; POM-7519A Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Type of meter: multimeter calibrator Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Kind of display used: LCD Software: Fluke Connect (FLK-IR3000FC) DC current measuring range: 1µA...30mA; 1A DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV AC current measuring range: 0.001mA...1A AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Diode test: 0.3mA @600mV Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz DC voltage measuring accuracy: ±(0.1% + 1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Dimensions: 203x100x50mm Resistance measuring accuracy: ±(0.2%+1 digit) AC voltage measuring accuracy: ±(0.7% + 2 digit) AC current measuring accuracy: ±(1% + 2 digit) Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71 Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-789/E | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Type of meter: multimeter calibrator Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Related items: POM-5900A/POM; POM-6173A; POM-7519A Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Software: Fluke Connect (FLK-IR3000FC) Diode test: 0.3mA @600mV DC current measuring range: 1µA...30mA; 1A AC current measuring range: 0.001mA...1A AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ Dimensions: 203x100x50mm DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1.2% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω Interface: IrDA |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLUKE-88-5/A KIT | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD DC voltage measuring range: 0...1kV AC voltage measuring range: 0...1kV DC current measuring range: 0...10A AC current measuring range: 0...10A True effective value measurement: True RMS AC Resistance measuring range: 0...50MΩ Frequency measuring range: 0...200kHz Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds Continuity test: acoustic indication Bargraph: yes Temperature measuring range: -200...1090°C Capacitance measuring range: 0...10000µF Diode test: 3V Dimensions (W x H x D): 86x186x32mm Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220 Battery/ rechargeable battery: battery 6F22 9V x1 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-279FC/IFLEX | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter with infrared camera; Bluetooth Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Interface: Bluetooth Connectors for the country: Europe; Great Britain Focusing: focus free Non-contact temperature measuring range: -10...200°C DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Capacitance measuring range: 1000nF...9999µF AC current measuring range: 100mA...999.9A; 2.5kA Diode test: 2V Frequency measuring range: 99.99...999.9Hz Resistance measuring range: 600Ω...50MΩ Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C Refresh rate: 8Hz Camera resolution: 80x60 Emissivity value: 0,95 (fixed) Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Type of meter: digital multimeter with infrared camera Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLK-3000FC | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Type of meter: digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: compatible Android; Fluke Connect IP rating: IP54 Kind of display used: LCD True effective value measurement: True RMS Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 60mA; 400mA DC current measuring range: 60mA; 400mA DC voltage measuring accuracy: ±(0.09% + 2 digit) Dimensions (W x H x D): 93x207x48mm Frequency measuring accuracy: ±(0.1%+1 digit) AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Resistance measuring accuracy: ±(0.5%+1 digit) DC current measuring accuracy: ±(0.5% + 3 digit) DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Diode test: 2V Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz Weight with battery: 340g Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-1587 T | FLUKE |
![]() ![]() Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Power supply: battery LR6 AA 1,5V x4 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Type of meter: digital multimeter Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Kind of display used: LCD Optional equipment: FLK-C25 soft cover IP rating: IP40 True effective value measurement: True RMS Illumination: yes Temperature measuring range: -40...537°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA DC current measuring range: 10µA...60mA; 400mA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @6V DC voltage measuring accuracy: ±(0.09% + 2 digit) Frequency measuring accuracy: ±(0.1%+1 digit) Resistance measuring accuracy: ±(0.9%+2 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring accuracy: ±(1% + 3 digit) Temperature measurement accuracy: ±(1% + 10 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring accuracy: ±(1.2%+ 2 digit) Test voltage: 50V; 100V Insulation resistance measuring ranges: 10kΩ...100MΩ Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Continuity test: acoustic indication; <25Ω Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-123B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Continuity test: acoustic indication Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Related items: POM-72941; POM-72942 Manufacturer series: FLUKE 120B IP rating: IP51 Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 20n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 20MHz Sampling: 40Msps Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +15 |
FLUKE-123B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Software: Fluke View Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Continuity test: acoustic indication Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Related items: POM-72941; POM-72942 Manufacturer series: FLUKE 120B IP rating: IP51 Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 20n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 20MHz Sampling: 40Msps Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +16 |
FLUKE-124B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Continuity test: acoustic indication Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Manufacturer series: FLUKE 120B Additional functions: multimeter Type of oscilloscope: scopemeter IP rating: IP51 Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +15 |
FLUKE-124B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Continuity test: acoustic indication Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Manufacturer series: FLUKE 120B Software: Fluke View Additional functions: multimeter Type of oscilloscope: scopemeter IP rating: IP51 Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-125B/EU | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Band: 40MHz Continuity test: acoustic indication Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Manufacturer series: FLUKE 120B Additional functions: multimeter Type of oscilloscope: scopemeter IP rating: IP51 Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +16 |
FLUKE-125B/EU/S | FLUKE |
![]() ![]() ![]() ![]() ![]() Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View IP rating: IP51 Additional functions: multimeter Type of oscilloscope: scopemeter Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Time base: 10n...60s/div Diode test: 0.5mA @2.8V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring accuracy: ±(0.6%+5 digit) Dimensions: 259x132x55mm Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Manufacturer series: FLUKE 120B Band: 40MHz Sampling: 40Msps Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +3 |
FLUKE-1587 FC | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Continuity test: acoustic indication; <25Ω Power supply: battery LR6 AA 1,5V x4 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B IP rating: IP40 True effective value measurement: True RMS AC Illumination: yes Temperature measuring range: -40...537°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Diode test: 1mA @6V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Temperature measurement resolution: 0.1°C Dimensions (W x H x D): 100x203x50mm DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Test voltage: 500V Weight with battery: 550g Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Optional equipment: FLK-C25 soft cover Display parameters: (6000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature |
auf Bestellung 11 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLK-115/TLK-225-1 | FLUKE |
![]() ![]() Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Manufacturer series: Fluke 110 True effective value measurement: True RMS AC DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 1mA...6A; 10A; (20A <30s) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) Dimensions (W x H x D): 84x167x46mm Resistance measuring accuracy: ±(0.9%+1 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω |
auf Bestellung 143 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-27II/EUR | FLUKE |
![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 IP rating: IP67 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR6 AA 1,5V x3 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +7 |
FLUKE-28II/EUR | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS IP rating: IP67 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA True effective value measurement: True RMS Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR6 AA 1,5V x3 |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-28IIEX | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s IP rating: IP67 Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA True effective value measurement: True RMS Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000/19999) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR03 AAA 1,5V x3 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +10 |
FLUKE-381 | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Related items: POM-5913; POM-6173A; POM-7519A Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m) Power supply: battery LR03 AAA 1,5V x5 Type of meter: multifunction Kind of display used: LCD Kind of meter: digital; pincers type True effective value measurement: True RMS Illumination: yes DC current measuring range: 100mA...1kA DC voltage measuring range: 100mV...600V; 1kV AC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...600V; 1kV Frequency measuring accuracy: ±(0.5%+5 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ Frequency measuring range: 5...500Hz Max. diameter of measured cable: 34mm DC voltage measuring accuracy: ±(1.5% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) Body dimensions: 277x88x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-83-5/EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S IP rating: IP30 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60S Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.4%+1 digit) Dimensions (W x H x D): 95x200x48mm DC current measuring accuracy: ±(0.4% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1.2% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Power supply: battery 6F22 9V x1 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +6 |
FLUKE-87-5/EUR | FLUKE |
![]() ![]() ![]() ![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Type of meter: digital multimeter Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD IP rating: IP30 True effective value measurement: True RMS AC Illumination: yes Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @3V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 95x200x48mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Bargraph: 33 segm. 40x/s Weight with battery: 600g Display parameters: (6000/20000) |
auf Bestellung 36 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
FLUKE-87V-MAX | FLUKE |
![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads IP rating: IP67 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes Temperature measuring range: -200...1090°C DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s Diode test: 1mA @3V Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.05% + 1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Type of meter: digital multimeter Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-87V-MAX/E2 KIT | FLUKE |
![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 IP rating: IP67 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes Temperature measuring range: -200...1090°C DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s Diode test: 1mA @3V Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.05% + 1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Type of meter: digital multimeter Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLK-87VMAX-PVLEAD1 | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67 Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4 IP rating: IP67 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes Temperature measuring range: -200...1090°C DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s Diode test: 1mA @3V Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.05% + 1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 4 digit) Resistance measuring accuracy: ±(0.2%+1 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Type of meter: digital multimeter Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-374 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Dimensions: 246x83x43mm Interface: Bluetooth Software: Fluke Connect Kind of meter: digital; pincers type True effective value measurement: True RMS Illumination: yes DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 100mA...600A DC current measuring range: 100mA...600A Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm DC current measuring accuracy: ±(2% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Related items: POM-5913; POM-6173A; POM-7519A Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance Continuity test: acoustic indication; <30Ω Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Type of meter: multifunction Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Test: diodes Kind of display used: LCD |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-375 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Dimensions: 246x83x43mm Interface: Bluetooth Software: Fluke Connect Kind of meter: digital; pincers type True effective value measurement: True RMS Illumination: yes DC voltage measuring range: 100mV...1kV AC voltage measuring range: 0.1mV...1kV Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 100mA...600A DC current measuring range: 100mA...600A Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm DC current measuring accuracy: ±(2% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Related items: POM-5913; POM-6173A; POM-7519A Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Type of meter: multifunction Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Test: diodes Kind of display used: LCD |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +12 |
FLUKE-376 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Related items: POM-5913; POM-6173A; POM-7519A Standard equipment: case; flexible current probe; FLK-TL75 test leads Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless Type of meter: multifunction Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Kind of meter: digital; pincers type Software: Fluke Connect True effective value measurement: True RMS Illumination: yes Capacitance measuring range: 1...1000µF AC current measuring range: 100mA...1kA DC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...1kV DC voltage measuring range: 0.1mV...1kV Resistance measuring range: 0.1...60kΩ Frequency measuring range: 100mHz...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Dimensions: 246x83x43mm Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) Pollution degree: 2 CF crest factor: 2.5 @ 600A Weight with battery: 388g |
auf Bestellung 63 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-902 FC | FLUKE |
![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Related items: POM-5900A/POM; POM-5907A; POM-6041B Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads Conform to the norm: CAT III 600V; EN 61010 Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip Kind of meter: digital; pincers type Software: Fluke Connect Type of meter: multifunction Kind of display used: LCD Resistance to: shockproof True effective value measurement: True RMS AC Illumination: yes Capacitance measuring range: 0.1...100µF; 1mF DC voltage measuring range: 100mV...600V AC current measuring range: 100mA...600A DC current measuring range: 0.1...200µA AC voltage measuring range: 100mV...600V Resistance measuring range: 100mΩ...999Ω; 9.999kΩ Max. diameter of measured cable: 30mm Dimensions: 240x80x40mm DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(1% + 5 digit) AC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring accuracy: ±(1.5%+5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Weight with battery: 310g Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication; <30Ω Measuring instruments application: air conditioning; heating industry; ventilation |
auf Bestellung 9 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-323 | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30 Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Type of meter: multifunction Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Kind of meter: digital; pincers type IP rating: IP30 True effective value measurement: True RMS DC voltage measuring range: 100mV...400V; 600V AC current measuring range: 100mA...400A AC voltage measuring range: 100mV...400V; 600V Current measuring resolution: 0.1A Resistance measuring range: 100mΩ...400Ω; 4kΩ Max. diameter of measured cable: 30mm DC voltage measuring accuracy: ±(1% + 5 digit) Dimensions: 207x75x34mm Resistance measuring accuracy: ±(1%+5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Bandwidth for AC current measurements: 45...400Hz Bandwidth for AC voltage measurements: 45...400Hz Weight with battery: 265g Display parameters: 3,5 digit Standard equipment: case; test leads Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; DC voltage; resistance Continuity test: acoustic indication; <70Ω |
auf Bestellung 87 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-325 | FLUKE |
![]() ![]() ![]() ![]() ![]() ![]() Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Type of meter: multifunction Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD Kind of meter: digital; pincers type IP rating: IP30 True effective value measurement: True RMS Illumination: yes DC current measuring range: 10mA...40A; 400A DC voltage measuring range: 100mV...400V; 600V Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 10mA...40A; 400A AC voltage measuring range: 100mV...400V; 600V Current measuring resolution: 10mA Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ Frequency measuring range: 5...500Hz Max. diameter of measured cable: 30mm DC voltage measuring accuracy: ±(1% + 5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 207x75x34mm Resistance measuring accuracy: ±(1%+5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) Bandwidth for AC current measurements: 45...400Hz Bandwidth for AC voltage measurements: 45...400Hz Weight with battery: 283g Display parameters: 3,5 digit Standard equipment: case; test leads Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <30Ω |
auf Bestellung 115 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +6 |
FLUKE-378 FC/E | FLUKE |
![]() Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Dimensions: 274x86x47mm Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175 Interface: Bluetooth Software: Fluke Connect Kind of meter: digital; pincers type True effective value measurement: True RMS Illumination: yes DC voltage measuring range: 600V; 1kV AC voltage measuring range: 600V; 1kV Capacitance measuring range: 0.1...100µF; 1mF AC current measuring range: 100mA...999.9A DC current measuring range: 100mA...999.9A Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Resistance measuring range: 600Ω; 6kΩ; 60kΩ DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm DC current measuring accuracy: ±(2% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Pollution degree: 2 Weight with battery: 463g Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Type of meter: multifunction Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Test: diodes Kind of display used: LCD |
auf Bestellung 26 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() |
TL71-1 | FLUKE |
Category: Test Leads - Sets Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2 Colour: red and black Test lead configuration: banana plug 4mm; probe tip Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Wire insulation material: silicone Type of test accessories: test leads Kit contents: test leads x2 Current rating: 10A Cable length: 1.5m Rated voltage: 1kV |
auf Bestellung 77 Stücke: Lieferzeit 14-21 Tag (e) |
|
PLS 6G RBP KIT |
![]() ![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
PLS 6G RBP SYS |
![]() ![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
PLS 6R RBP KIT |
![]() ![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 30h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; red laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 30h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; red laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLK-393FC-PVLEAD |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Max. diameter of measured cable: 34mm
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Kind of meter: digital; pincers type
Software: Fluke Connect
Kind of display used: LCD
Type of meter: multifunction
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Dimensions: 281x84x49mm
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
AC current measuring accuracy: ±(2% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Frequency measuring range: 5...500Hz
Weight with battery: 520g
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Continuity test: acoustic indication; <30Ω
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Interface: Bluetooth
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Max. diameter of measured cable: 34mm
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Kind of meter: digital; pincers type
Software: Fluke Connect
Kind of display used: LCD
Type of meter: multifunction
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Dimensions: 281x84x49mm
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
AC current measuring accuracy: ±(2% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Frequency measuring range: 5...500Hz
Weight with battery: 520g
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Continuity test: acoustic indication; <30Ω
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Interface: Bluetooth
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1015.79 EUR |
FLK-393-IRR-PVLEAD |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1484.63 EUR |
TI-CAR CHARGER |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: car charger
Type of test accessories: car charger
Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32
Category: Fluke Infrared Cameras
Description: Test acces: car charger
Type of test accessories: car charger
Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLK-TI-SBP3 |
![]() ![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: accu pack; 2.5h; 7.4V
Type of test accessories: accu pack
Related items: FLK-TI32; FLK-TIR32
Body dimensions: 124x58.4x42.4mm
Charge time: 2.5h
Rated voltage: 7.4V
Category: Fluke Infrared Cameras
Description: Test acces: accu pack; 2.5h; 7.4V
Type of test accessories: accu pack
Related items: FLK-TI32; FLK-TIR32
Body dimensions: 124x58.4x42.4mm
Charge time: 2.5h
Rated voltage: 7.4V
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLK-TI-TRIPOD2 |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: stand mount
Type of test accessories: stand mount
Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125
Category: Fluke Infrared Cameras
Description: Test acces: stand mount
Type of test accessories: stand mount
Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLUKE-287/EUR |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Kind of display used: colour; LCD TFT 2,2"
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Kind of display used: colour; LCD TFT 2,2"
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
auf Bestellung 13 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1194.12 EUR |
FLUKE-289/EUR |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: FLK-TL175 test leads; holder for probes
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 2,2"
Software: Fluke Connect (FLK-IR3000FC)
Manufacturer series: FOX
IP rating: IP54
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Conductance measurement: 10000000...50nS
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Measurement memory: 10k
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (50000)
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: FLK-TL175 test leads; holder for probes
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 2,2"
Software: Fluke Connect (FLK-IR3000FC)
Manufacturer series: FOX
IP rating: IP54
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Conductance measurement: 10000000...50nS
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Weight with battery: 871g
Display resolution: 320x240
Measurement memory: 10k
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (50000)
auf Bestellung 21 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1298.73 EUR |
FLK-TIS20+ MAX 9HZ |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC
Standard equipment: battery charger; case; power supply; USB cable
Thermal sensitivity (NETD): 60mK
Interface: USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Three-dimensional resolution: 7.6mrad
Dimensions: 26.7x10.1x14.5mm
Measurement: temperature
Focusing: FocusFree
Measuring unit: °C; °F
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC
Standard equipment: battery charger; case; power supply; USB cable
Thermal sensitivity (NETD): 60mK
Interface: USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Three-dimensional resolution: 7.6mrad
Dimensions: 26.7x10.1x14.5mm
Measurement: temperature
Focusing: FocusFree
Measuring unit: °C; °F
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 2513.22 EUR |
FLUKE-114 EUR |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <20Ω
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <20Ω
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 292.75 EUR |
FLUKE-116 EUR |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Measuring instruments application: air conditioning; heating industry; ventilation
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Continuity test: acoustic indication; <20Ω
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Measuring instruments application: air conditioning; heating industry; ventilation
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Continuity test: acoustic indication; <20Ω
auf Bestellung 30 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 415.01 EUR |
FLUKE-117 EUR |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
auf Bestellung 41 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 425.21 EUR |
FLUKE-175 EGFID |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
DC voltage measuring accuracy: ±(0.15% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 89x190x45mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
DC voltage measuring accuracy: ±(0.15% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 89x190x45mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Standard equipment: FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
auf Bestellung 96 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 439.83 EUR |
FLUKE-177 EGFID |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
auf Bestellung 92 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 514.66 EUR |
FLUKE-179 EGFID |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 170
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
auf Bestellung 113 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 626.83 EUR |
FLUKE-1577 |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1111.01 EUR |
2824477 |
Hersteller: FLUKE
Category: Accessories - Others
Description: Battery container
Related items: FLK-289
Type of test accessories: battery container
Category: Accessories - Others
Description: Battery container
Related items: FLK-289
Type of test accessories: battery container
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 91.89 EUR |
FLK-3000FC/EDA2 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 727.68 EUR |
FLUKE-179/EDA2/EUR |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 693.78 EUR |
FLUKE-179/MAG2 KIT |
![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Category: Portable digital multimeters
Description: Digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 603.17 EUR |
FLUKE-T110 |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 42 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 140.81 EUR |
FLUKE T110/VDE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 135.14 EUR |
FLUKE-T90 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP54
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Body dimensions: 245x64x28mm
Weight with battery: 180g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Measurement: AC voltage; DC voltage
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Bandwidth for AC voltage measurements: 0...400Hz
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring accuracy: ±(3% + 5 digit)
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Additional functions: illumination lamp
IP rating: IP54
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Body dimensions: 245x64x28mm
Weight with battery: 180g
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 98.36 EUR |
FLUKE-T130 |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 36 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 203.78 EUR |
FLUKE T130/VDE |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 13 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 206.49 EUR |
FLUKE-T150 |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 112 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 234.98 EUR |
FLUKE T150/VDE |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Resistance measuring range: 1...1999Ω
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 52 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 240.45 EUR |
FLUKE-787B |
![]() ![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: multimeter calibrator
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Kind of display used: LCD
Software: Fluke Connect (FLK-IR3000FC)
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: multimeter calibrator
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Kind of display used: LCD
Software: Fluke Connect (FLK-IR3000FC)
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
DC voltage measuring accuracy: ±(0.1% + 1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1990.4 EUR |
FLUKE-789/E |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Diode test: 0.3mA @600mV
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Dimensions: 203x100x50mm
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Interface: IrDA
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Software: Fluke Connect (FLK-IR3000FC)
Diode test: 0.3mA @600mV
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Dimensions: 203x100x50mm
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Interface: IrDA
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 2279.49 EUR |
FLUKE-88-5/A KIT |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
DC current measuring range: 0...10A
AC current measuring range: 0...10A
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Frequency measuring range: 0...200kHz
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Continuity test: acoustic indication
Bargraph: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 0...10000µF
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Battery/ rechargeable battery: battery 6F22 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
DC current measuring range: 0...10A
AC current measuring range: 0...10A
True effective value measurement: True RMS AC
Resistance measuring range: 0...50MΩ
Frequency measuring range: 0...200kHz
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Continuity test: acoustic indication
Bargraph: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 0...10000µF
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Battery/ rechargeable battery: battery 6F22 9V x1
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1231.56 EUR |
FLUKE-279FC/IFLEX |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
Diode test: 2V
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Type of meter: digital multimeter with infrared camera
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
Diode test: 2V
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Type of meter: digital multimeter with infrared camera
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1688.03 EUR |
FLK-3000FC |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
IP rating: IP54
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Dimensions (W x H x D): 93x207x48mm
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Resistance measuring accuracy: ±(0.5%+1 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Diode test: 2V
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Weight with battery: 340g
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
IP rating: IP54
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Dimensions (W x H x D): 93x207x48mm
Frequency measuring accuracy: ±(0.1%+1 digit)
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Resistance measuring accuracy: ±(0.5%+1 digit)
DC current measuring accuracy: ±(0.5% + 3 digit)
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Diode test: 2V
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Weight with battery: 340g
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 547.55 EUR |
FLUKE-1587 T |
![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring accuracy: ±(1% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring accuracy: ±(1% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1243.79 EUR |
FLUKE-123B/EU |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 2867.44 EUR |
FLUKE-123B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Software: Fluke View
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Software: Fluke View
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Related items: POM-72941; POM-72942
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 3774.07 EUR |
FLUKE-124B/EU |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 3468.21 EUR |
FLUKE-124B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Software: Fluke View
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Software: Fluke View
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 4333.62 EUR |
FLUKE-125B/EU |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Band: 40MHz
Continuity test: acoustic indication
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
Additional functions: multimeter
Type of oscilloscope: scopemeter
IP rating: IP51
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 4142.18 EUR |
FLUKE-125B/EU/S |
![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Time base: 10n...60s/div
Diode test: 0.5mA @2.8V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Dimensions: 259x132x55mm
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Manufacturer series: FLUKE 120B
Band: 40MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Time base: 10n...60s/div
Diode test: 0.5mA @2.8V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring accuracy: ±(0.6%+5 digit)
Dimensions: 259x132x55mm
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Manufacturer series: FLUKE 120B
Band: 40MHz
Sampling: 40Msps
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLUKE-1587 FC |
![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
IP rating: IP40
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement resolution: 0.1°C
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Optional equipment: FLK-C25 soft cover
Display parameters: (6000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Continuity test: acoustic indication; <25Ω
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
IP rating: IP40
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement resolution: 0.1°C
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Test voltage: 500V
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Optional equipment: FLK-C25 soft cover
Display parameters: (6000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1358.5 EUR |
FLK-115/TLK-225-1 |
![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
auf Bestellung 143 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 408.91 EUR |
FLUKE-27II/EUR |
![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLUKE-28II/EUR |
![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
IP rating: IP67
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1052.22 EUR |
FLUKE-28IIEX |
![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
IP rating: IP67
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000/19999)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR03 AAA 1,5V x3
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
IP rating: IP67
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000/19999)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR03 AAA 1,5V x3
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 2521.33 EUR |
FLUKE-381 |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Power supply: battery LR03 AAA 1,5V x5
Type of meter: multifunction
Kind of display used: LCD
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Body dimensions: 277x88x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Related items: POM-5913; POM-6173A; POM-7519A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Power supply: battery LR03 AAA 1,5V x5
Type of meter: multifunction
Kind of display used: LCD
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Body dimensions: 277x88x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1081.37 EUR |
FLUKE-83-5/EUR |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
IP rating: IP30
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Power supply: battery 6F22 9V x1
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
IP rating: IP30
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Power supply: battery 6F22 9V x1
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
FLUKE-87-5/EUR |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
IP rating: IP30
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Weight with battery: 600g
Display parameters: (6000/20000)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Type of meter: digital multimeter
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
IP rating: IP30
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Weight with battery: 600g
Display parameters: (6000/20000)
auf Bestellung 36 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 752.61 EUR |
FLUKE-87V-MAX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 964.74 EUR |
FLUKE-87V-MAX/E2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1140.63 EUR |
FLK-87VMAX-PVLEAD1 |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
IP rating: IP67
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Temperature measuring range: -200...1090°C
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
Diode test: 1mA @3V
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1092.72 EUR |
FLUKE-374 FC |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 246x83x43mm
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 246x83x43mm
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 670.24 EUR |
FLUKE-375 FC |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 246x83x43mm
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 246x83x43mm
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 100mV...1kV
AC voltage measuring range: 0.1mV...1kV
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...600A
DC current measuring range: 100mA...600A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Related items: POM-5913; POM-6173A; POM-7519A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 779.38 EUR |
FLUKE-376 FC |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Related items: POM-5913; POM-6173A; POM-7519A
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
Software: Fluke Connect
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 1...1000µF
AC current measuring range: 100mA...1kA
DC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
DC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 0.1...60kΩ
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Dimensions: 246x83x43mm
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Pollution degree: 2
CF crest factor: 2.5 @ 600A
Weight with battery: 388g
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Related items: POM-5913; POM-6173A; POM-7519A
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Type of meter: multifunction
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
Software: Fluke Connect
True effective value measurement: True RMS
Illumination: yes
Capacitance measuring range: 1...1000µF
AC current measuring range: 100mA...1kA
DC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
DC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 0.1...60kΩ
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Dimensions: 246x83x43mm
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Pollution degree: 2
CF crest factor: 2.5 @ 600A
Weight with battery: 388g
auf Bestellung 63 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 878.94 EUR |
FLUKE-902 FC |
![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Software: Fluke Connect
Type of meter: multifunction
Kind of display used: LCD
Resistance to: shockproof
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
DC voltage measuring range: 100mV...600V
AC current measuring range: 100mA...600A
DC current measuring range: 0.1...200µA
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Weight with battery: 310g
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Software: Fluke Connect
Type of meter: multifunction
Kind of display used: LCD
Resistance to: shockproof
True effective value measurement: True RMS AC
Illumination: yes
Capacitance measuring range: 0.1...100µF; 1mF
DC voltage measuring range: 100mV...600V
AC current measuring range: 100mA...600A
DC current measuring range: 0.1...200µA
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring accuracy: ±(1.5%+5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Weight with battery: 310g
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 546.55 EUR |
FLUKE-323 |
![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
IP rating: IP30
True effective value measurement: True RMS
DC voltage measuring range: 100mV...400V; 600V
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ
Max. diameter of measured cable: 30mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Dimensions: 207x75x34mm
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Display parameters: 3,5 digit
Standard equipment: case; test leads
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
IP rating: IP30
True effective value measurement: True RMS
DC voltage measuring range: 100mV...400V; 600V
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
Resistance measuring range: 100mΩ...400Ω; 4kΩ
Max. diameter of measured cable: 30mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Dimensions: 207x75x34mm
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Display parameters: 3,5 digit
Standard equipment: case; test leads
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
auf Bestellung 87 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 209.9 EUR |
FLUKE-325 |
![]() ![]() ![]() ![]() ![]() ![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
IP rating: IP30
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 10mA...40A; 400A
DC voltage measuring range: 100mV...400V; 600V
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 10mA
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 30mm
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Display parameters: 3,5 digit
Standard equipment: case; test leads
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
Kind of meter: digital; pincers type
IP rating: IP30
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 10mA...40A; 400A
DC voltage measuring range: 100mV...400V; 600V
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 10mA
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 30mm
DC voltage measuring accuracy: ±(1% + 5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Display parameters: 3,5 digit
Standard equipment: case; test leads
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
auf Bestellung 115 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 367.15 EUR |
FLUKE-378 FC/E |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 274x86x47mm
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...999.9A
DC current measuring range: 100mA...999.9A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Weight with battery: 463g
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Dimensions: 274x86x47mm
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Interface: Bluetooth
Software: Fluke Connect
Kind of meter: digital; pincers type
True effective value measurement: True RMS
Illumination: yes
DC voltage measuring range: 600V; 1kV
AC voltage measuring range: 600V; 1kV
Capacitance measuring range: 0.1...100µF; 1mF
AC current measuring range: 100mA...999.9A
DC current measuring range: 100mA...999.9A
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
DC current measuring accuracy: ±(2% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Weight with battery: 463g
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Type of meter: multifunction
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Test: diodes
Kind of display used: LCD
auf Bestellung 26 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
1+ | 1016.99 EUR |
TL71-1 |
Hersteller: FLUKE
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Type of test accessories: test leads
Kit contents: test leads x2
Current rating: 10A
Cable length: 1.5m
Rated voltage: 1kV
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Type of test accessories: test leads
Kit contents: test leads x2
Current rating: 10A
Cable length: 1.5m
Rated voltage: 1kV
auf Bestellung 77 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis |
---|---|
2+ | 60.05 EUR |