| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
||
|---|---|---|---|---|---|---|---|
![]() +1 |
FLUKE-1503 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Body dimensions: 203x100x50mm Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Related items: POM-5674C; POM-5907A; POM-6041B Type of meter: insulation resistance IP rating: IP40 Kind of display used: LCD Illumination: yes Automatic discharging capacitance: max. 1µF Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ AC voltage measuring range: 100mV...600V DC voltage measuring range: 100mV...600V Capacitance discharge time: <0.5s Resistance measuring accuracy: ±(1.5%+3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Open circuit test voltage: 4...8V Test voltage: 500V DC; 1kV DC Bandwidth for AC voltage measurements: 50...400Hz Weight with battery: 550g Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ Continuity test: acoustic indication Measurement: AC voltage; DC voltage; insulation resistance; resistance Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT IV 600V; EN 61010 Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X |
auf Bestellung 11 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
FLUKE-1507 | FLUKE |
Category: Insulation Resistance MetersDescription: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Body dimensions: 203x100x50mm Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Related items: POM-5674C; POM-5907A; POM-6041B Type of meter: insulation resistance IP rating: IP40 Kind of display used: LCD Illumination: yes Automatic discharging capacitance: max. 1µF Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ AC voltage measuring range: 100mV...600V DC voltage measuring range: 100mV...600V Capacitance discharge time: <0.5s Resistance measuring accuracy: ±(1.5%+3 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Open circuit test voltage: 4...8V Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC Bandwidth for AC voltage measurements: 50...400Hz Weight with battery: 550g Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ Continuity test: acoustic indication Measurement: AC voltage; DC voltage; insulation resistance; resistance Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT IV 600V; EN 61010 Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X |
auf Bestellung 87 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-179-2/IMSK | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Type of measuring kit: multimeters |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-87V/IMSK | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; test leads TL75 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz DC voltage measuring accuracy: ±(0.05% + 1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(0.2%+1 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Display parameters: (6000/20000) Pollution degree: 2 Bargraph: 33 segm. 40x/s Conductance measuring accuracy: ±(1% + 10digit) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Power supply: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLK-DS703 FC | FLUKE |
Category: Inspection Cameras, BoroscopesDescription: Inspection camera; Display: LCD 7"; 68°; Cam.res: 1200x720; 6GB Type of meter: inspection camera Kind of display used: LCD 7" Camera resolution: 1200x720 IP rating: IP54; IP68 (probe) Power supply: rechargeable battery Li-Ion 3,7V x1 Measuring instrument features: automatic image orientation; digital zoom x8; dual view camera, from forward and side of the probe; LED for measurement spot illumination Standard equipment: battery charger/power supply; hand strap; HDMI cable; magnetic hanging strap; neckstrap; soft case; USB cable Interface: WiFi Resistance to: fall from 2m height Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Supported formats: AVI; JPEG Touchpad: yes Probe diameter: 8.5mm Dimensions: 173.3x224.8mm Cable length: 1.2m Viewing angle: 68° Weight with battery: 880g Memory capacity: 6GB Software: Fluke Connect Kind of connector: HDMI; USB |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLK-PTI120 9HZ 400C | FLUKE |
Category: Fluke Infrared CamerasDescription: Infrared camera; LCD 3,5"; 120x90; -20÷150°C; Focus: focus free Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 120x90 Temperature measuring range: -20...150°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 50° horizontal x 38° vertical IP rating: IP54 Body dimensions: 89x127x25mm Power supply: rechargeable battery Li-Ion 3,7V x1 Measuring instrument features: AutoBlend function; compact design; IR-Fusion function to combine thermal and real images; multilanguage menu; picture-in-picture (PIP) function; radiometric measurements for detailed temperature analysis; transfer measurement data wireless Standard equipment: case; hand strap; USB cable Interface: WiFi Resistance to: fall from 1m height Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1 Display resolution: 320x240 Supported formats: IS2; JPG Touchpad: yes Three-dimensional resolution: 7.6mrad Weight with battery: 233g Optical resolution: 130:1 Focusing: focus free Software: Fluke Connect |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
T6-1000PRO/EU | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LCD; VAC: 1÷1000V; VDC: 1÷1000V; I AC: 200A; IP52 Type of tester: electrical Measuring instrument features: autoranging; FieldSense - non-contact measurement of voltage, current and frequency; HOLD function Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285 Resistance to: fall from 3m height IP rating: IP52 Kind of display used: LCD Related items: POM-5912B; POM-6041B; POM-6232A True effective value measurement: True RMS Illumination: yes Body dimensions: 61.1x259.3x43.8mm AC current measuring range: 200A DC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(1%+2 digit) AC voltage measuring range: 1...1000V DC voltage measuring range: 1...1000V Resistance measuring range: 2kΩ; 20kΩ; 100kΩ AC voltage measuring accuracy: ±(1.5% + 2 digit) AC current measuring accuracy: ±(3% + 3 digit) Producer guarantee (months): 24 Measurement frequency: 45...66Hz Weight with battery: 499g Continuity test: acoustic indication Standard equipment: crocodile clips FLK-AC285; holster FLK-HT-6; test leads |
auf Bestellung 11 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
T5-1000 EUR1 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LCD; (1000); VAC: 1÷1000V; VDC: 1÷1000V; IP52 Type of tester: electrical Measuring instrument features: automatic power-off; autoranging; compact design with compartment for test leads; easy current measurement due to open-jaw technology; measures automatically AC/DC with precise resolution Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Optional equipment: FLK-C33 soft cover; FLK-H5 belt holster Resistance to: fall from 3m height IP rating: IP52 Kind of display used: LCD Related items: POM-5912B; POM-6041B; POM-6232A True effective value measurement: True RMS AC Body dimensions: 203x51x30.5mm AC current measuring range: 100mA...100A DC voltage measuring accuracy: ±(1% + 1 digit) Resistance measuring accuracy: ±(1%+2 digit) AC voltage measuring range: 1...1000V DC voltage measuring range: 1...1000V Resistance measuring range: 1...1000Ω AC voltage measuring accuracy: ±(1.5% + 2 digit) Weight with battery: 380g Display parameters: (1000) Measurement: AC current; AC voltage; DC voltage; resistance Continuity test: 0Ω...400kΩ Standard equipment: test leads |
auf Bestellung 40 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
PLS 6G RBP KIT | FLUKE |
Category: Meters of Env. Conditions - OthersDescription: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 12h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; green laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
|
PLS 6G RBP SYS | FLUKE |
Category: Meters of Env. Conditions - OthersDescription: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 12h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; green laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
|
PLS 6R RBP KIT | FLUKE |
Category: Meters of Env. Conditions - OthersDescription: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2 Body dimensions: 116x64x104mm Operating temperature: -10...50°C Nominal life: 30h Range: 30m Producer guarantee (months): 36 Vertical/horizontal viewing angle: 130/180° Laser class: 2 Measurement accuracy: ≤3mm @ 0...10m Tools features: automatic leveling; red laser Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1 Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS IP rating: IP54 Type of tool: laser level |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +8 |
FLK-393FC-PVLEAD | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010 Software: Fluke Connect Kind of meter: digital; pincers type Kind of display used: LCD True effective value measurement: True RMS Illumination: yes DC current measuring range: 100mA...999.9A AC current measuring range: 100mA...999.9A AC voltage measuring range: 600V; 1kV DC voltage measuring range: 600V; 1.5kV Capacitance measuring range: 0.1...100µF; 1mF Frequency measuring accuracy: ±(0.5%+5 digit) Frequency measuring range: 5...500Hz Max. diameter of measured cable: 34mm DC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring range: 600Ω; 6kΩ; 60kΩ Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 281x84x49mm AC voltage measuring accuracy: ±(1% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) Pollution degree: 2 Weight with battery: 520g CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4 Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance Continuity test: acoustic indication; <30Ω Type of meter: multifunction Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
FLK-393-IRR-PVLEAD | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010 Software: Fluke Connect Kind of meter: digital; pincers type Kind of display used: LCD True effective value measurement: True RMS Illumination: yes DC current measuring range: 100mA...999.9A AC current measuring range: 100mA...999.9A AC voltage measuring range: 600V; 1kV DC voltage measuring range: 600V; 1.5kV Capacitance measuring range: 0.1...100µF; 1mF Frequency measuring accuracy: ±(0.5%+5 digit) Frequency measuring range: 5...500Hz Max. diameter of measured cable: 34mm DC voltage measuring accuracy: ±(1% + 5 digit) Resistance measuring range: 600Ω; 6kΩ; 60kΩ Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 281x84x49mm AC voltage measuring accuracy: ±(1% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) Pollution degree: 2 Weight with battery: 520g CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4 Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance Continuity test: acoustic indication; <30Ω Type of meter: multifunction Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
TI-CAR CHARGER | FLUKE |
Category: Fluke Infrared Cameras Description: Test acces: car charger Type of test accessories: car charger Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
|
FLK-TI-SBP3 | FLUKE |
Category: Fluke Infrared CamerasDescription: Test acces: accu pack; 2.5h; 7.4V Type of test accessories: accu pack Related items: FLK-TI32; FLK-TIR32 Body dimensions: 124x58.4x42.4mm Charge time: 2.5h Rated voltage: 7.4V |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
|
FLK-TI-TRIPOD2 | FLUKE |
Category: Fluke Infrared CamerasDescription: Test acces: stand mount Type of test accessories: stand mount Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +5 |
FLUKE-287/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Standard equipment: holder for probes; test leads FLK-TL71 Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Software: Fluke Connect (FLK-IR3000FC) IP rating: IP54 Kind of display used: LCD TFT 2,2" True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) Conductance measurement: 10000000...50nS DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Display resolution: 320x240 Weight with battery: 871g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Measurement memory: 10k Display parameters: (50000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Manufacturer series: FLUKE 280 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 12 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +8 |
FLUKE-289/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Standard equipment: FLK-TL175 test leads; holder for probes Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Software: Fluke Connect (FLK-IR3000FC) IP rating: IP54 Kind of display used: LCD TFT 2,2" True effective value measurement: True RMS AC; True RMS AC+DC Temperature measuring range: -200...1350°C Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Diode test: 1mA @3.1V Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Frequency measuring accuracy: ±(0.005%+5 digit) Conductance measurement: 10000000...50nS DC voltage measuring accuracy: ±(0.025% + 2 digit) Resistance measuring accuracy: ±(0.05%+2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) Dimensions (W x H x D): 102x222x60mm Temperature measurement resolution: 0.1°C AC voltage measuring accuracy: ±(0.4% + 20 digit) AC current measuring accuracy: ±(0.6% + 5 digit) Temperature measurement accuracy: ±(1% + 1°C) Capacitance measuring accuracy: ±(1%+ 5 digit) Conductance measuring accuracy: ±(1% + 10digit) Duty cycle factor: 1...99% Pollution degree: 2 Bargraph: 51 segm. Display resolution: 320x240 Weight with battery: 871g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Measurement memory: 10k Display parameters: (50000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Continuity test: acoustic indication Manufacturer series: FOX Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 16 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLK-TIS20+ MAX 9HZ | FLUKE |
Category: Fluke Infrared CamerasDescription: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 120x90 Temperature measuring range: -20...400°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 50° horizontal x 38° vertical IP rating: IP54 Power supply: rechargeable battery Li-Ion x1 Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC Standard equipment: battery charger; case; power supply; USB cable Thermal sensitivity (NETD): 60mK Interface: USB; WiFi Resistance to: fall from 2m height Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Display resolution: 320x240 Measurement: temperature Three-dimensional resolution: 7.6mrad Dimensions: 26.7x10.1x14.5mm Focusing: FocusFree Measuring unit: °C; °F |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-114 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 600V; EN 61010 Continuity test: acoustic indication; <20Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Type of meter: digital multimeter Related items: POM-5673B; POM-5900A/POM; POM-7519A Manufacturer series: Fluke 110 Kind of display used: LCD True effective value measurement: True RMS AC DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm AC voltage measuring accuracy: ±(1% + 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222 Measurement: AC voltage; DC voltage; resistance |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-116 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) Temperature measuring range: -40...400°C Temperature measurement accuracy: ±(0.1% + 2 digit) Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA DC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Weight with battery: 550g Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Continuity test: acoustic indication; <20Ω Measuring instruments application: air conditioning; heating industry; ventilation Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s |
auf Bestellung 30 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-117 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 600V; EN 61010 Continuity test: acoustic indication; <20Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Type of meter: digital multimeter Related items: POM-5673B; POM-5900A/POM; POM-7519A Manufacturer series: Fluke 110 Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 1mA...6A; 10A; (20A <30s) DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
auf Bestellung 20 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-175 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Continuity test: acoustic indication; <25Ω Weight with battery: 420g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery 6LR61 9V x1 Bargraph: 33 segm. 40x/s Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Manufacturer series: Fluke 170 Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm Capacitance measuring accuracy: ±(1.2%+ 2 digit) |
auf Bestellung 90 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-177 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals DC current measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Continuity test: acoustic indication; <25Ω Weight with battery: 420g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery 6LR61 9V x1 Bargraph: 33 segm. 40x/s Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Manufacturer series: Fluke 170 Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) Dimensions (W x H x D): 89x190x45mm Capacitance measuring accuracy: ±(1.2%+ 2 digit) |
auf Bestellung 86 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-179 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads Type of meter: digital multimeter Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Manufacturer series: Fluke 170 Kind of display used: LCD True effective value measurement: True RMS AC Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Temperature measurement accuracy: ±(1% + 10 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Display parameters: 3,75 digit (6000) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 98 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-1577 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover IP rating: IP40 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Dimensions (W x H x D): 100x203x50mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(1.2%+2 digit) AC current measuring accuracy: ±(2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V; 1kV Weight with battery: 550g Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
2824477 | FLUKE |
Category: Accessories - Others Description: Battery container Type of test accessories: battery container Related items: FLK-289 |
auf Bestellung 15 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLK-3000FC/EDA2 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910 Type of meter: digital multimeter Related items: POM-5677B; POM-5899A; POM-7519A |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-179/EDA2/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Battery/ rechargeable battery: battery 6LR61 9V x1 Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip Type of meter: digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +8 |
FLUKE-179/MAG2 KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Type of meter: digital multimeter Related items: POM-5904A/POM; POM-6343; POM-7519A |
auf Bestellung 9 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T110 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 12...690V AC Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 42 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T110/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-T90 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT II 690V; CAT III 600V; EN 61010 IP rating: IP54 Kind of display used: LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 245x64x28mm DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 12...690V AC Weight with battery: 180g Measurement: AC voltage; DC voltage Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 54 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T130 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 25 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T130/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Type of tester: electrical Additional functions: illumination lamp IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Weight with battery: 270g Display parameters: 3,5 digit Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Measurement: AC voltage; DC voltage Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 13 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T150 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Resistance measuring range: 1...1999Ω AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage; resistance Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 79 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T150/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 IP rating: IP64 Kind of display used: LCD; LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Resistance measuring range: 1...1999Ω AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 100...690V AC Weight with battery: 270g Display parameters: 3,5 digit Measurement: AC voltage; DC voltage; resistance Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 41 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-787B | FLUKE |
Category: CalibratorsDescription: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Type of meter: multimeter calibrator Kind of display used: LCD DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV DC voltage measuring accuracy: ±(0.1% + 1 digit) AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring accuracy: ±(0.7% + 2 digit) DC current measuring range: 1µA...30mA; 1A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.001mA...1A AC current measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Diode test: 0.3mA @600mV Continuity test: acoustic indication; <100Ω Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Related items: POM-5900A/POM; POM-6173A; POM-7519A Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Dimensions: 203x100x50mm Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Software: Fluke Connect (FLK-IR3000FC) |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-789/E | FLUKE |
Category: CalibratorsDescription: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Type of meter: multimeter calibrator Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Kind of display used: LCD DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV DC voltage measuring accuracy: ±(0.1% + 1 digit) AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring accuracy: ±(1.2% + 4 digit) DC current measuring range: 1µA...30mA; 1A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.001mA...1A AC current measuring accuracy: ±(1% + 2 digit) Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Diode test: 0.3mA @600mV Continuity test: acoustic indication; <100Ω Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Related items: POM-5900A/POM; POM-6173A; POM-7519A Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Dimensions: 203x100x50mm Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Interface: IrDA Software: Fluke Connect (FLK-IR3000FC) |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLUKE-88-5/A KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ Type of meter: digital multimeter Kind of display used: LCD Temperature measuring range: -200...1090°C Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 0...10000µF AC current measuring range: 0...10A DC current measuring range: 0...10A DC voltage measuring range: 0...1kV AC voltage measuring range: 0...1kV Frequency measuring range: 0...200kHz Resistance measuring range: 0...50MΩ Diode test: 3V Dimensions (W x H x D): 86x186x32mm Continuity test: acoustic indication Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Bargraph: yes |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-279FC/IFLEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter with infrared camera; Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Interface: Bluetooth Type of meter: digital multimeter with infrared camera Connectors for the country: Europe; Great Britain Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Focusing: focus free Non-contact temperature measuring range: -10...200°C Capacitance measuring range: 1000nF...9999µF AC current measuring range: 100mA...999.9A; 2.5kA DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Diode test: 2V Resistance measuring range: 600Ω...50MΩ Frequency measuring range: 99.99...999.9Hz Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C Refresh rate: 8Hz Camera resolution: 80x60 Emissivity value: 0,95 (fixed) Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLK-3000FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads Interface: Bluetooth Software: compatible Android; Fluke Connect Type of meter: digital multimeter Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A IP rating: IP54 Kind of display used: LCD True effective value measurement: True RMS Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 60mA; 400mA DC current measuring range: 60mA; 400mA DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Diode test: 2V Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.5%+1 digit) Dimensions (W x H x D): 93x207x48mm DC current measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Weight with battery: 340g Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-1587 T | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Type of meter: digital multimeter Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Kind of display used: LCD Optional equipment: FLK-C25 soft cover IP rating: IP40 True effective value measurement: True RMS Illumination: yes Temperature measuring range: -40...537°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @6V DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Frequency measuring accuracy: ±(0.1%+1 digit) Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C AC current measuring accuracy: ±(1.5% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring accuracy: ±(1.2%+ 2 digit) Test voltage: 50V; 100V Insulation resistance measuring ranges: 10kΩ...100MΩ Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Continuity test: acoustic indication; <25Ω Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-123B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 20n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 20MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe IP rating: IP51 Additional functions: multimeter |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +15 |
FLUKE-123B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 20n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 20MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View IP rating: IP51 Additional functions: multimeter |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +16 |
FLUKE-124B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe IP rating: IP51 Additional functions: multimeter |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +15 |
FLUKE-124B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View IP rating: IP51 Additional functions: multimeter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-125B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Related items: POM-72941; POM-72942 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe IP rating: IP51 Additional functions: multimeter |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +16 |
FLUKE-125B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Manufacturer series: FLUKE 120B Dimensions: 259x132x55mm Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View IP rating: IP51 Additional functions: multimeter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-1587 FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) Temperature measuring range: -40...537°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP40 Power supply: battery LR6 AA 1,5V x4 Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature Interface: Bluetooth Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Diode test: 1mA @6V Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Weight with battery: 550g Test voltage: 500V Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Optional equipment: FLK-C25 soft cover Continuity test: acoustic indication; <25Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Illumination: yes |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLK-115/TLK-225-1 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Battery/ rechargeable battery: battery 6LR61 9V x1 Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set Continuity test: acoustic indication; <20Ω Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster Power supply: battery 6LR61 9V x1 Type of meter: digital multimeter Conform to the norm: CAT III 600V; EN 61010 Manufacturer series: Fluke 110 Kind of display used: LCD True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 1mA...6A; 10A; 20A < 30s AC current measuring range: 1mA...6A; 10A; (20A <30s) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Dimensions (W x H x D): 84x167x46mm Resistance measuring accuracy: ±(0.9%+1 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Pollution degree: 2 Weight with battery: 550g Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance |
auf Bestellung 123 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-27II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP67 Power supply: battery LR6 AA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Standard equipment: test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-28II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP67 Power supply: battery LR6 AA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Standard equipment: test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-28IIEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/19999) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP67 Power supply: battery LR03 AAA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Standard equipment: test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Continuity test: acoustic indication Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +10 |
FLUKE-381 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Continuity test: acoustic indication; <30Ω Power supply: battery LR03 AAA 1,5V x5 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5913; POM-6173A; POM-7519A Kind of display used: LCD True effective value measurement: True RMS Illumination: yes AC current measuring range: 100mA...1kA DC current measuring range: 100mA...1kA DC voltage measuring range: 100mV...600V; 1kV AC voltage measuring range: 100mV...600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1.5% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Body dimensions: 277x88x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m) Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-83-5/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000) IP rating: IP30 Power supply: battery 6F22 9V x1 Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60S Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.4%+1 digit) Dimensions (W x H x D): 95x200x48mm DC current measuring accuracy: ±(0.4% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1.2% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +6 |
FLUKE-87-5/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/20000) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP30 Power supply: battery 6F22 9V x1 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 95x200x48mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 27 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-87V-MAX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/20000) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP67 Power supply: battery LR6 AA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-87V-MAX/E2 KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Type of meter: digital multimeter Kind of display used: LCD Display parameters: (6000/20000) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) IP rating: IP67 Power supply: battery LR6 AA 1,5V x3 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Illumination: yes |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLK-87VMAX-PVLEAD1 | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67 Display parameters: (6000/20000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD Illumination: yes True effective value measurement: True RMS AC Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Conductance measurement: 0.01...60nS DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz DC voltage measuring accuracy: ±(0.05% + 1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(0.2%+1 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Bargraph: 33 segm. 40x/s Weight with battery: 700g Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
| FLUKE-1503 |
![]() |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Related items: POM-5674C; POM-5907A; POM-6041B
Type of meter: insulation resistance
IP rating: IP40
Kind of display used: LCD
Illumination: yes
Automatic discharging capacitance: max. 1µF
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
AC voltage measuring range: 100mV...600V
DC voltage measuring range: 100mV...600V
Capacitance discharge time: <0.5s
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Open circuit test voltage: 4...8V
Test voltage: 500V DC; 1kV DC
Bandwidth for AC voltage measurements: 50...400Hz
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Continuity test: acoustic indication
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Related items: POM-5674C; POM-5907A; POM-6041B
Type of meter: insulation resistance
IP rating: IP40
Kind of display used: LCD
Illumination: yes
Automatic discharging capacitance: max. 1µF
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
AC voltage measuring range: 100mV...600V
DC voltage measuring range: 100mV...600V
Capacitance discharge time: <0.5s
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Open circuit test voltage: 4...8V
Test voltage: 500V DC; 1kV DC
Bandwidth for AC voltage measurements: 50...400Hz
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
Continuity test: acoustic indication
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 660.55 EUR |
| FLUKE-1507 |
![]() |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Related items: POM-5674C; POM-5907A; POM-6041B
Type of meter: insulation resistance
IP rating: IP40
Kind of display used: LCD
Illumination: yes
Automatic discharging capacitance: max. 1µF
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
AC voltage measuring range: 100mV...600V
DC voltage measuring range: 100mV...600V
Capacitance discharge time: <0.5s
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Open circuit test voltage: 4...8V
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Bandwidth for AC voltage measurements: 50...400Hz
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Continuity test: acoustic indication
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Body dimensions: 203x100x50mm
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Related items: POM-5674C; POM-5907A; POM-6041B
Type of meter: insulation resistance
IP rating: IP40
Kind of display used: LCD
Illumination: yes
Automatic discharging capacitance: max. 1µF
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
AC voltage measuring range: 100mV...600V
DC voltage measuring range: 100mV...600V
Capacitance discharge time: <0.5s
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Open circuit test voltage: 4...8V
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Bandwidth for AC voltage measurements: 50...400Hz
Weight with battery: 550g
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
Continuity test: acoustic indication
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
auf Bestellung 87 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 843.7 EUR |
| FLUKE-179-2/IMSK |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of measuring kit: multimeters
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Standard equipment: clamp meter FLK-323; crocodile clips FLK-AC175; digital multimeter FLK-179; FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Type of measuring kit: multimeters
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 783.15 EUR |
| FLUKE-87V/IMSK |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; test leads TL75
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Display parameters: (6000/20000)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Conductance measuring accuracy: ±(1% + 10digit)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Power supply: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; test leads TL75
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Display parameters: (6000/20000)
Pollution degree: 2
Bargraph: 33 segm. 40x/s
Conductance measuring accuracy: ±(1% + 10digit)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Power supply: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 932.87 EUR |
| FLK-DS703 FC |
![]() |
Hersteller: FLUKE
Category: Inspection Cameras, Boroscopes
Description: Inspection camera; Display: LCD 7"; 68°; Cam.res: 1200x720; 6GB
Type of meter: inspection camera
Kind of display used: LCD 7"
Camera resolution: 1200x720
IP rating: IP54; IP68 (probe)
Power supply: rechargeable battery Li-Ion 3,7V x1
Measuring instrument features: automatic image orientation; digital zoom x8; dual view camera, from forward and side of the probe; LED for measurement spot illumination
Standard equipment: battery charger/power supply; hand strap; HDMI cable; magnetic hanging strap; neckstrap; soft case; USB cable
Interface: WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Supported formats: AVI; JPEG
Touchpad: yes
Probe diameter: 8.5mm
Dimensions: 173.3x224.8mm
Cable length: 1.2m
Viewing angle: 68°
Weight with battery: 880g
Memory capacity: 6GB
Software: Fluke Connect
Kind of connector: HDMI; USB
Category: Inspection Cameras, Boroscopes
Description: Inspection camera; Display: LCD 7"; 68°; Cam.res: 1200x720; 6GB
Type of meter: inspection camera
Kind of display used: LCD 7"
Camera resolution: 1200x720
IP rating: IP54; IP68 (probe)
Power supply: rechargeable battery Li-Ion 3,7V x1
Measuring instrument features: automatic image orientation; digital zoom x8; dual view camera, from forward and side of the probe; LED for measurement spot illumination
Standard equipment: battery charger/power supply; hand strap; HDMI cable; magnetic hanging strap; neckstrap; soft case; USB cable
Interface: WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Supported formats: AVI; JPEG
Touchpad: yes
Probe diameter: 8.5mm
Dimensions: 173.3x224.8mm
Cable length: 1.2m
Viewing angle: 68°
Weight with battery: 880g
Memory capacity: 6GB
Software: Fluke Connect
Kind of connector: HDMI; USB
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4129.31 EUR |
| FLK-PTI120 9HZ 400C |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷150°C; Focus: focus free
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...150°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Body dimensions: 89x127x25mm
Power supply: rechargeable battery Li-Ion 3,7V x1
Measuring instrument features: AutoBlend function; compact design; IR-Fusion function to combine thermal and real images; multilanguage menu; picture-in-picture (PIP) function; radiometric measurements for detailed temperature analysis; transfer measurement data wireless
Standard equipment: case; hand strap; USB cable
Interface: WiFi
Resistance to: fall from 1m height
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Display resolution: 320x240
Supported formats: IS2; JPG
Touchpad: yes
Three-dimensional resolution: 7.6mrad
Weight with battery: 233g
Optical resolution: 130:1
Focusing: focus free
Software: Fluke Connect
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷150°C; Focus: focus free
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...150°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Body dimensions: 89x127x25mm
Power supply: rechargeable battery Li-Ion 3,7V x1
Measuring instrument features: AutoBlend function; compact design; IR-Fusion function to combine thermal and real images; multilanguage menu; picture-in-picture (PIP) function; radiometric measurements for detailed temperature analysis; transfer measurement data wireless
Standard equipment: case; hand strap; USB cable
Interface: WiFi
Resistance to: fall from 1m height
Battery/ rechargeable battery: rechargeable battery Li-Ion 3,7V x1
Display resolution: 320x240
Supported formats: IS2; JPG
Touchpad: yes
Three-dimensional resolution: 7.6mrad
Weight with battery: 233g
Optical resolution: 130:1
Focusing: focus free
Software: Fluke Connect
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1205.48 EUR |
| T6-1000PRO/EU |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; VAC: 1÷1000V; VDC: 1÷1000V; I AC: 200A; IP52
Type of tester: electrical
Measuring instrument features: autoranging; FieldSense - non-contact measurement of voltage, current and frequency; HOLD function
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285
Resistance to: fall from 3m height
IP rating: IP52
Kind of display used: LCD
Related items: POM-5912B; POM-6041B; POM-6232A
True effective value measurement: True RMS
Illumination: yes
Body dimensions: 61.1x259.3x43.8mm
AC current measuring range: 200A
DC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1%+2 digit)
AC voltage measuring range: 1...1000V
DC voltage measuring range: 1...1000V
Resistance measuring range: 2kΩ; 20kΩ; 100kΩ
AC voltage measuring accuracy: ±(1.5% + 2 digit)
AC current measuring accuracy: ±(3% + 3 digit)
Producer guarantee (months): 24
Measurement frequency: 45...66Hz
Weight with battery: 499g
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC285; holster FLK-HT-6; test leads
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; VAC: 1÷1000V; VDC: 1÷1000V; I AC: 200A; IP52
Type of tester: electrical
Measuring instrument features: autoranging; FieldSense - non-contact measurement of voltage, current and frequency; HOLD function
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: crocodile clip FLK-AC220; crocodile clip FLK-AC285
Resistance to: fall from 3m height
IP rating: IP52
Kind of display used: LCD
Related items: POM-5912B; POM-6041B; POM-6232A
True effective value measurement: True RMS
Illumination: yes
Body dimensions: 61.1x259.3x43.8mm
AC current measuring range: 200A
DC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1%+2 digit)
AC voltage measuring range: 1...1000V
DC voltage measuring range: 1...1000V
Resistance measuring range: 2kΩ; 20kΩ; 100kΩ
AC voltage measuring accuracy: ±(1.5% + 2 digit)
AC current measuring accuracy: ±(3% + 3 digit)
Producer guarantee (months): 24
Measurement frequency: 45...66Hz
Weight with battery: 499g
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC285; holster FLK-HT-6; test leads
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 466.41 EUR |
| T5-1000 EUR1 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; (1000); VAC: 1÷1000V; VDC: 1÷1000V; IP52
Type of tester: electrical
Measuring instrument features: automatic power-off; autoranging; compact design with compartment for test leads; easy current measurement due to open-jaw technology; measures automatically AC/DC with precise resolution
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C33 soft cover; FLK-H5 belt holster
Resistance to: fall from 3m height
IP rating: IP52
Kind of display used: LCD
Related items: POM-5912B; POM-6041B; POM-6232A
True effective value measurement: True RMS AC
Body dimensions: 203x51x30.5mm
AC current measuring range: 100mA...100A
DC voltage measuring accuracy: ±(1% + 1 digit)
Resistance measuring accuracy: ±(1%+2 digit)
AC voltage measuring range: 1...1000V
DC voltage measuring range: 1...1000V
Resistance measuring range: 1...1000Ω
AC voltage measuring accuracy: ±(1.5% + 2 digit)
Weight with battery: 380g
Display parameters: (1000)
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: 0Ω...400kΩ
Standard equipment: test leads
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LCD; (1000); VAC: 1÷1000V; VDC: 1÷1000V; IP52
Type of tester: electrical
Measuring instrument features: automatic power-off; autoranging; compact design with compartment for test leads; easy current measurement due to open-jaw technology; measures automatically AC/DC with precise resolution
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Optional equipment: FLK-C33 soft cover; FLK-H5 belt holster
Resistance to: fall from 3m height
IP rating: IP52
Kind of display used: LCD
Related items: POM-5912B; POM-6041B; POM-6232A
True effective value measurement: True RMS AC
Body dimensions: 203x51x30.5mm
AC current measuring range: 100mA...100A
DC voltage measuring accuracy: ±(1% + 1 digit)
Resistance measuring accuracy: ±(1%+2 digit)
AC voltage measuring range: 1...1000V
DC voltage measuring range: 1...1000V
Resistance measuring range: 1...1000Ω
AC voltage measuring accuracy: ±(1.5% + 2 digit)
Weight with battery: 380g
Display parameters: (1000)
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: 0Ω...400kΩ
Standard equipment: test leads
auf Bestellung 40 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 307.91 EUR |
| PLS 6G RBP KIT |
![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| PLS 6G RBP SYS |
![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 12h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; green laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; green line laser detector with bracket PLS SLD Green; laser level PLS 6G; magnetic holder PLS MLB; magnetic reflective target plate for green lasers PLS GRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| PLS 6R RBP KIT |
![]() |
Hersteller: FLUKE
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 30h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; red laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Category: Meters of Env. Conditions - Others
Description: Laser level; Meas.accur: ≤3mm @ 0÷10m; Range: 30m; Laser class: 2
Body dimensions: 116x64x104mm
Operating temperature: -10...50°C
Nominal life: 30h
Range: 30m
Producer guarantee (months): 36
Vertical/horizontal viewing angle: 130/180°
Laser class: 2
Measurement accuracy: ≤3mm @ 0...10m
Tools features: automatic leveling; red laser
Power supply: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Battery/ rechargeable battery: battery LR6 AA 1,5V x3; rechargeable battery Li-Ion PLS RBP5 3,6V 5200mAh x1
Kit contents: ceiling/ wall bracket PLS UB9; charger; laser level PLS 6R; magnetic holder PLS MLB; magnetic reflective target plate for red lasers PLS RRT4; soft case PLS-60573; stand PLS FS
IP rating: IP54
Type of tool: laser level
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-393FC-PVLEAD |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 987.01 EUR |
| FLK-393-IRR-PVLEAD |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
Category: PV and EVSE Testers and Meters
Description: Meter: multifunction; VAC accuracy: ±(1%+5digit); VAC: 600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1500V; CAT IV 600V; EN 61010
Software: Fluke Connect
Kind of meter: digital; pincers type
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
AC voltage measuring range: 600V; 1kV
DC voltage measuring range: 600V; 1.5kV
Capacitance measuring range: 0.1...100µF; 1mF
Frequency measuring accuracy: ±(0.5%+5 digit)
Frequency measuring range: 5...500Hz
Max. diameter of measured cable: 34mm
DC voltage measuring accuracy: ±(1% + 5 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 281x84x49mm
AC voltage measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Pollution degree: 2
Weight with battery: 520g
CF crest factor: 1.42k @ 2.5kA; 2.5k @ 600A; 3k @ 1.1kA
Standard equipment: case; FLK-IRR1-SOL meter; iFlex2500-18 - current clamp; magnetic hanging strap; test leads ( 2pcs.); test leads MC4
Measurement: AC current; AC voltage; capacitance; continuity; current (with current clamps); DC current; DC voltage; frequency; inrush current; peak current; resistance
Continuity test: acoustic indication; <30Ω
Type of meter: multifunction
Measuring instrument features: AUTO HOLD; automatic power-off; flexible current probe up to 2500A; HOLD function; MIN/MAX/AVG function; polarization indicator
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1399.48 EUR |
| TI-CAR CHARGER |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: car charger
Type of test accessories: car charger
Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32
Category: Fluke Infrared Cameras
Description: Test acces: car charger
Type of test accessories: car charger
Related items: FLK-TI10/9HZ; FLK-TI25; FLK-TI32; FLK-TIR1/9HZ; FLK-TIR32
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-TI-SBP3 |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: accu pack; 2.5h; 7.4V
Type of test accessories: accu pack
Related items: FLK-TI32; FLK-TIR32
Body dimensions: 124x58.4x42.4mm
Charge time: 2.5h
Rated voltage: 7.4V
Category: Fluke Infrared Cameras
Description: Test acces: accu pack; 2.5h; 7.4V
Type of test accessories: accu pack
Related items: FLK-TI32; FLK-TIR32
Body dimensions: 124x58.4x42.4mm
Charge time: 2.5h
Rated voltage: 7.4V
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-TI-TRIPOD2 |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Test acces: stand mount
Type of test accessories: stand mount
Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125
Category: Fluke Infrared Cameras
Description: Test acces: stand mount
Type of test accessories: stand mount
Related items: FLK-TI100; FLK-TI110; FLK-TI125; FLK-TIR110; FLK-TIR125
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-287/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: holder for probes; test leads FLK-TL71
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
auf Bestellung 12 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1186.67 EUR |
| FLUKE-289/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: FLK-TL175 test leads; holder for probes
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FOX
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Category: Portable digital multimeters
Description: Digital multimeter; LCD TFT 2,2"; (50000); 320x240; Resol: 0.1°C
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Standard equipment: FLK-TL175 test leads; holder for probes
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Software: Fluke Connect (FLK-IR3000FC)
IP rating: IP54
Kind of display used: LCD TFT 2,2"
True effective value measurement: True RMS AC; True RMS AC+DC
Temperature measuring range: -200...1350°C
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Diode test: 1mA @3.1V
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Frequency measuring accuracy: ±(0.005%+5 digit)
Conductance measurement: 10000000...50nS
DC voltage measuring accuracy: ±(0.025% + 2 digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
Dimensions (W x H x D): 102x222x60mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(0.4% + 20 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Capacitance measuring accuracy: ±(1%+ 5 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Duty cycle factor: 1...99%
Pollution degree: 2
Bargraph: 51 segm.
Display resolution: 320x240
Weight with battery: 871g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Measurement memory: 10k
Display parameters: (50000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Continuity test: acoustic indication
Manufacturer series: FOX
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1268.98 EUR |
| FLK-TIS20+ MAX 9HZ |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC
Standard equipment: battery charger; case; power supply; USB cable
Thermal sensitivity (NETD): 60mK
Interface: USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Measurement: temperature
Three-dimensional resolution: 7.6mrad
Dimensions: 26.7x10.1x14.5mm
Focusing: FocusFree
Measuring unit: °C; °F
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 120x90; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 120x90
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 50° horizontal x 38° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; IR-Fusion function to combine thermal and real images; wireless communication with PC
Standard equipment: battery charger; case; power supply; USB cable
Thermal sensitivity (NETD): 60mK
Interface: USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Measurement: temperature
Three-dimensional resolution: 7.6mrad
Dimensions: 26.7x10.1x14.5mm
Focusing: FocusFree
Measuring unit: °C; °F
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2388.5 EUR |
| FLUKE-114 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
AC voltage measuring accuracy: ±(1% + 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Measurement: AC voltage; DC voltage; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
AC voltage measuring accuracy: ±(1% + 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Measurement: AC voltage; DC voltage; resistance
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 292.75 EUR |
| FLUKE-116 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0.1% + 2 digit)
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0.1% + 2 digit)
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
auf Bestellung 30 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 415.01 EUR |
| FLUKE-117 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 418.1 EUR |
| FLUKE-175 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
auf Bestellung 90 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 437.05 EUR |
| FLUKE-177 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Continuity test: acoustic indication; <25Ω
Weight with battery: 420g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery 6LR61 9V x1
Bargraph: 33 segm. 40x/s
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Manufacturer series: Fluke 170
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
auf Bestellung 86 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 514.66 EUR |
| FLUKE-179 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Type of meter: digital multimeter
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 98 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 617.59 EUR |
| FLUKE-1577 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Dimensions (W x H x D): 100x203x50mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Weight with battery: 550g
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1097.05 EUR |
| 2824477 |
Hersteller: FLUKE
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
auf Bestellung 15 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 86.69 EUR |
| FLK-3000FC/EDA2 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 708.85 EUR |
| FLUKE-179/EDA2/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Type of meter: digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Type of meter: digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 695.78 EUR |
| FLUKE-179/MAG2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Related items: POM-5904A/POM; POM-6343; POM-7519A
auf Bestellung 9 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 582.72 EUR |
| FLUKE-T110 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 42 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 140.81 EUR |
| FLUKE T110/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 135.14 EUR |
| FLUKE-T90 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 54 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 96.27 EUR |
| FLUKE-T130 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 25 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 203.78 EUR |
| FLUKE T130/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Type of tester: electrical
Additional functions: illumination lamp
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Type of tester: electrical
Additional functions: illumination lamp
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 13 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 206.49 EUR |
| FLUKE-T150 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 79 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 234.98 EUR |
| FLUKE T150/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
IP rating: IP64
Kind of display used: LCD; LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Resistance measuring range: 1...1999Ω
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Measurement: AC voltage; DC voltage; resistance
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 41 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 235.09 EUR |
| FLUKE-787B |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Kind of display used: LCD
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(0.7% + 2 digit)
DC current measuring range: 1µA...30mA; 1A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.001mA...1A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Diode test: 0.3mA @600mV
Continuity test: acoustic indication; <100Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Software: Fluke Connect (FLK-IR3000FC)
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Kind of display used: LCD
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(0.7% + 2 digit)
DC current measuring range: 1µA...30mA; 1A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.001mA...1A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Diode test: 0.3mA @600mV
Continuity test: acoustic indication; <100Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Software: Fluke Connect (FLK-IR3000FC)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1904.69 EUR |
| FLUKE-789/E |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Kind of display used: LCD
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1.2% + 4 digit)
DC current measuring range: 1µA...30mA; 1A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.001mA...1A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Diode test: 0.3mA @600mV
Continuity test: acoustic indication; <100Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Interface: IrDA
Software: Fluke Connect (FLK-IR3000FC)
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Type of meter: multimeter calibrator
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Kind of display used: LCD
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
DC voltage measuring accuracy: ±(0.1% + 1 digit)
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring accuracy: ±(1.2% + 4 digit)
DC current measuring range: 1µA...30mA; 1A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.001mA...1A
AC current measuring accuracy: ±(1% + 2 digit)
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Diode test: 0.3mA @600mV
Continuity test: acoustic indication; <100Ω
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Dimensions: 203x100x50mm
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Interface: IrDA
Software: Fluke Connect (FLK-IR3000FC)
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2262.29 EUR |
| FLUKE-88-5/A KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Temperature measuring range: -200...1090°C
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 0...10000µF
AC current measuring range: 0...10A
DC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Type of meter: digital multimeter
Kind of display used: LCD
Temperature measuring range: -200...1090°C
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 0...10000µF
AC current measuring range: 0...10A
DC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1223.79 EUR |
| FLUKE-279FC/IFLEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω...50MΩ
Frequency measuring range: 99.99...999.9Hz
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Interface: Bluetooth
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω...50MΩ
Frequency measuring range: 99.99...999.9Hz
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1688.03 EUR |
| FLK-3000FC |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Interface: Bluetooth
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
IP rating: IP54
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Interface: Bluetooth
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
IP rating: IP54
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 548.66 EUR |
| FLUKE-1587 T |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Frequency measuring accuracy: ±(0.1%+1 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1217.19 EUR |
| FLUKE-123B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-123B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-124B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 3422.58 EUR |
| FLUKE-124B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4183.61 EUR |
| FLUKE-125B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Related items: POM-72941; POM-72942
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
IP rating: IP51
Additional functions: multimeter
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-125B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Manufacturer series: FLUKE 120B
Dimensions: 259x132x55mm
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
IP rating: IP51
Additional functions: multimeter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4878.39 EUR |
| FLUKE-1587 FC |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -40...537°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP40
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Interface: Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Weight with battery: 550g
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -40...537°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP40
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Interface: Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Weight with battery: 550g
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Illumination: yes
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1319.6 EUR |
| FLK-115/TLK-225-1 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Battery/ rechargeable battery: battery 6LR61 9V x1
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Power supply: battery 6LR61 9V x1
Type of meter: digital multimeter
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Dimensions (W x H x D): 84x167x46mm
Resistance measuring accuracy: ±(0.9%+1 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
auf Bestellung 123 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 399.83 EUR |
| FLUKE-27II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1018.99 EUR |
| FLUKE-28II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1011.75 EUR |
| FLUKE-28IIEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/19999)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR03 AAA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Standard equipment: test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2424.36 EUR |
| FLUKE-381 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
AC current measuring range: 100mA...1kA
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Body dimensions: 277x88x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
AC current measuring range: 100mA...1kA
DC current measuring range: 100mA...1kA
DC voltage measuring range: 100mV...600V; 1kV
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Body dimensions: 277x88x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1051.22 EUR |
| FLUKE-83-5/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 726.05 EUR |
| FLUKE-87-5/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP30
Power supply: battery 6F22 9V x1
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 27 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 752.49 EUR |
| FLUKE-87V-MAX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 968.44 EUR |
| FLUKE-87V-MAX/E2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: (6000/20000)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
IP rating: IP67
Power supply: battery LR6 AA 1,5V x3
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Illumination: yes
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1140.63 EUR |
| FLK-87VMAX-PVLEAD1 |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Display parameters: (6000/20000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS AC
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 700g
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Display parameters: (6000/20000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS AC
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Conductance measurement: 0.01...60nS
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 700g
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1022.42 EUR |