| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
||
|---|---|---|---|---|---|---|---|
![]() +4 |
FLUKE-116 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication; <20Ω Measuring instruments application: air conditioning; heating industry; ventilation Standard equipment: FLK-TL75 test leads Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 Type of meter: digital multimeter Manufacturer series: Fluke 110 Kind of display used: LCD True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA AC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Diode test: 1.2mA @2.7V Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm Temperature measurement accuracy: ±(0.1% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Weight with battery: 550g Display parameters: 3,75 digit (6000) Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature |
auf Bestellung 28 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-117 EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 600V; EN 61010 Manufacturer series: Fluke 110 Type of meter: digital multimeter Related items: POM-5673B; POM-5900A/POM; POM-7519A Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 1mA...6A; 10A; 20A < 30s AC current measuring range: 1mA...6A; 10A; (20A <30s) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster |
auf Bestellung 43 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-175 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Type of meter: digital multimeter Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Manufacturer series: Fluke 170 Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.15% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Display parameters: 3,75 digit (6000) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals |
auf Bestellung 80 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-177 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: FLK-TL75 test leads Type of meter: digital multimeter Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Manufacturer series: Fluke 170 Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1.1mA @2.4V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Bargraph: 33 segm. 40x/s Weight with battery: 420g Display parameters: 3,75 digit (6000) Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals |
auf Bestellung 76 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-179 EGFID | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Continuity test: acoustic indication; <25Ω Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter Manufacturer series: Fluke 170 Kind of display used: LCD True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Temperature measuring range: -40...400°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 10µA...60mA; 400mA; 6A; 10A AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Diode test: 1.1mA @2.4V Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 89x190x45mm Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Weight with battery: 420g Display parameters: 3,75 digit (6000) Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 84 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +4 |
FLUKE-1577 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Kind of display used: LCD Display parameters: (6000) Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 10µA...60mA; 400mA True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Resistance measuring accuracy: ±(1.2%+2 digit) Continuity test: acoustic indication; <25Ω Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Power supply: battery LR6 AA 1,5V x4 Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Weight with battery: 550g Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Illumination: yes Dimensions (W x H x D): 100x203x50mm DC current measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(2% + 2 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Test voltage: 500V; 1kV Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover IP rating: IP40 DC current measuring range: 10µA...60mA; 400mA |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +1 |
2824477 | FLUKE |
Category: Accessories - Others Description: Battery container Type of test accessories: battery container Related items: FLK-289 |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLK-3000FC/EDA2 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910 Type of meter: digital multimeter Related items: POM-5677B; POM-5899A; POM-7519A |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-179/EDA2/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Type of meter: digital multimeter Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip Related items: POM-5904A/POM; POM-6343; POM-7519A Battery/ rechargeable battery: battery 6LR61 9V x1 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +8 |
FLUKE-179/MAG2 KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Type of meter: digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 Related items: POM-5904A/POM; POM-6343; POM-7519A |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T110 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Type of tester: electrical Kind of display used: LEDs Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp IP rating: IP64 Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 12...690V AC Weight with battery: 270g Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Measurement: AC voltage; DC voltage Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 39 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T110/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-T90 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ Type of tester: electrical Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Additional functions: illumination lamp Conform to the norm: CAT II 690V; CAT III 600V; EN 61010 IP rating: IP54 Kind of display used: LEDs Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 245x64x28mm DC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring accuracy: ±(3% + 5 digit) Phase-to-phase voltage range for phase sequence indication: 12...690V AC Weight with battery: 180g Measurement: AC voltage; DC voltage Continuity test: acoustic indication; optical indication; 0Ω...400kΩ |
auf Bestellung 50 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T130 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Kind of display used: LCD; LEDs Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp IP rating: IP64 Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Measurement: AC voltage; DC voltage Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 24 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T130/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LCD; LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Display parameters: 3,5 digit Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-T150 | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64 Type of tester: electrical Kind of display used: LCD; LEDs Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Additional functions: illumination lamp IP rating: IP64 Bandwidth for AC voltage measurements: 0...400Hz Body dimensions: 255x78x35mm Resistance measuring range: 1...1999Ω DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 6...690V AC Weight with battery: 270g Display parameters: 3,5 digit Continuity test: acoustic indication; optical indication; 0Ω...400kΩ Measurement: AC voltage; DC voltage; resistance Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 |
auf Bestellung 45 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE T150/VDE | FLUKE |
Category: Indicators, Voltage & Continuity TestersDescription: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64 Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010 Kind of display used: LCD; LEDs IP rating: IP64 Additional functions: illumination lamp Type of tester: electrical Display parameters: 3,5 digit Bandwidth for AC voltage measurements: 0...400Hz Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Body dimensions: 255x78x35mm Power supply: battery LR03 AAA 1,5V x2 Resistance measuring range: 1...1999Ω Continuity test: acoustic indication; optical indication; 0Ω...400kΩ DC voltage measuring accuracy: ±(3% + 5 digit) AC voltage measuring accuracy: ±(3% + 5 digit) Resistance measuring accuracy: ±(5%+10 digit) DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V Phase-to-phase voltage range for phase sequence indication: 100...690V AC Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button Weight with battery: 270g Measurement: AC voltage; DC voltage; resistance |
auf Bestellung 29 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-787B | FLUKE |
Category: CalibratorsDescription: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Continuity test: acoustic indication; <100Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Type of meter: multimeter calibrator Related items: POM-5900A/POM; POM-6173A; POM-7519A Software: Fluke Connect (FLK-IR3000FC) Kind of display used: LCD DC current measuring range: 1µA...30mA; 1A AC current measuring range: 0.001mA...1A AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV Diode test: 0.3mA @600mV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Dimensions: 203x100x50mm AC voltage measuring accuracy: ±(0.7% + 2 digit) AC current measuring accuracy: ±(1% + 2 digit) Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-789/E | FLUKE |
Category: CalibratorsDescription: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <100Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Interface: IrDA Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Type of meter: multimeter calibrator Related items: POM-5900A/POM; POM-6173A; POM-7519A Software: Fluke Connect (FLK-IR3000FC) Kind of display used: LCD DC current measuring range: 1µA...30mA; 1A AC current measuring range: 0.001mA...1A AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV Diode test: 0.3mA @600mV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Dimensions: 203x100x50mm AC voltage measuring accuracy: ±(1.2% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLUKE-88-5/A KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter Kind of display used: LCD True effective value measurement: True RMS AC Bargraph: yes Temperature measuring range: -200...1090°C Capacitance measuring range: 0...10000µF DC current measuring range: 0...10A AC current measuring range: 0...10A DC voltage measuring range: 0...1kV AC voltage measuring range: 0...1kV Frequency measuring range: 0...200kHz Resistance measuring range: 0...50MΩ Diode test: 3V Dimensions (W x H x D): 86x186x32mm Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-279FC/IFLEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter with infrared camera; Bluetooth Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Continuity test: acoustic indication; <25Ω Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter with infrared camera Connectors for the country: Europe; Great Britain Focusing: focus free Non-contact temperature measuring range: -10...200°C Capacitance measuring range: 1000nF...9999µF AC current measuring range: 100mA...999.9A; 2.5kA DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 99.99...999.9Hz Resistance measuring range: 600Ω...50MΩ Diode test: 2V Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C Refresh rate: 8Hz Camera resolution: 80x60 Emissivity value: 0,95 (fixed) Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +5 |
FLK-3000FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV IP rating: IP54 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Software: compatible Android; Fluke Connect Type of meter: digital multimeter Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A Kind of display used: LCD True effective value measurement: True RMS Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF AC current measuring range: 60mA; 400mA DC current measuring range: 60mA; 400mA AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Diode test: 2V Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.5%+1 digit) Dimensions (W x H x D): 93x207x48mm DC current measuring accuracy: ±(0.5% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Weight with battery: 340g Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Power supply: battery LR6 AA 1,5V x3 Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +5 |
FLUKE-1587 T | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Type of meter: digital multimeter Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Kind of display used: LCD Optional equipment: FLK-C25 soft cover IP rating: IP40 True effective value measurement: True RMS Illumination: yes Temperature measuring range: -40...537°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 1mA @6V Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Resistance measuring accuracy: ±(0.9%+2 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Test voltage: 50V; 100V Insulation resistance measuring ranges: 10kΩ...100MΩ Display parameters: (6000) Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Continuity test: acoustic indication; <25Ω Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-123B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div IP rating: IP51 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 20n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 20MHz Manufacturer series: FLUKE 120B Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Related items: POM-72941; POM-72942 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +15 |
FLUKE-123B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Kind of display used: colour; LCD TFT 5,7" DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Resistance measuring accuracy: ±(0.6%+5 digit) Diode test: 0.5mA @2.8V Continuity test: acoustic indication Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Related items: POM-72941; POM-72942 Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Band: 20MHz Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Software: Fluke View Connectors for the country: Europe Manufacturer series: FLUKE 120B IP rating: IP51 Additional functions: multimeter Type of oscilloscope: scopemeter Time base: 20n...60s/div Dimensions: 259x132x55mm Number of channels: 2 Display resolution: 640x480 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +16 |
FLUKE-124B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div IP rating: IP51 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Manufacturer series: FLUKE 120B Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Related items: POM-72941; POM-72942 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +15 |
FLUKE-124B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div IP rating: IP51 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Manufacturer series: FLUKE 120B Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Related items: POM-72941; POM-72942 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-125B/EU | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div IP rating: IP51 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Manufacturer series: FLUKE 120B Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance Related items: POM-72941; POM-72942 |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +16 |
FLUKE-125B/EU/S | FLUKE |
Category: Portable Oscilloscopes, ScopemetersDescription: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div IP rating: IP51 Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Kind of display used: colour; LCD TFT 5,7" Connectors for the country: Europe Software: Fluke View Additional functions: multimeter Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Type of oscilloscope: scopemeter Time base: 10n...60s/div Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Dimensions: 259x132x55mm AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V DC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(0.6%+5 digit) Number of channels: 2 Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ Display resolution: 640x480 Band: 40MHz Manufacturer series: FLUKE 120B Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Sampling: 40Msps Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Continuity test: acoustic indication Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-1587 FC | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B Continuity test: acoustic indication; <25Ω Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Power supply: battery LR6 AA 1,5V x4 Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP40 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Temperature measuring range: -40...537°C Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF DC current measuring range: 10µA...60mA; 400mA AC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Diode test: 1mA @6V Frequency measuring accuracy: ±(0.1%+1 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Dimensions (W x H x D): 100x203x50mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Weight with battery: 550g Test voltage: 500V Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Optional equipment: FLK-C25 soft cover Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature |
auf Bestellung 14 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +13 |
FLK-115/TLK-225-1 | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set Type of meter: digital multimeter Power supply: battery 6LR61 9V x1 Battery/ rechargeable battery: battery 6LR61 9V x1 Conform to the norm: CAT III 600V; EN 61010 Manufacturer series: Fluke 110 Kind of display used: LCD True effective value measurement: True RMS AC Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF AC current measuring range: 1mA...6A; 10A; (20A <30s) DC current measuring range: 1mA...6A; 10A; 20A < 30s AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Diode test: 1.2mA @2.7V Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Frequency measuring accuracy: ±(0.1%+2 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Dimensions (W x H x D): 84x167x46mm DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) Pollution degree: 2 Bargraph: 33 segm. 32x/s Weight with battery: 550g Display parameters: 3,75 digit (6000) Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <20Ω Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster |
auf Bestellung 118 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-27II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) AC current measuring accuracy: ±(1.5% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-28II/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-28IIEX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: test leads Power supply: battery LR03 AAA 1,5V x3 Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A Duty cycle factor: 0...99.9% DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @2.8V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 100x198x63.5mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 517g Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Display parameters: (6000/19999) Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +10 |
FLUKE-381 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Power supply: battery LR03 AAA 1,5V x5 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5913; POM-6173A; POM-7519A Kind of display used: LCD Illumination: yes True effective value measurement: True RMS DC current measuring range: 100mA...1kA AC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...600V; 1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC voltage measuring range: 100mV...600V; 1kV Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Body dimensions: 277x88x43mm DC voltage measuring accuracy: ±(1.5% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m) |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +5 |
FLUKE-83-5/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP30 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60S Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.4%+1 digit) Dimensions (W x H x D): 95x200x48mm DC current measuring accuracy: ±(0.4% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1.2% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +6 |
FLUKE-87-5/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP30 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 95x200x48mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 20 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-87V-MAX | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Continuity test: acoustic indication Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLUKE-87V-MAX/E2 KIT | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Continuity test: acoustic indication Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
FLK-87VMAX-PVLEAD1 | FLUKE |
Category: PV and EVSE Testers and Meters Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Continuity test: acoustic indication Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4 Power supply: battery LR6 AA 1,5V x3 Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP67 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Temperature measuring range: -200...1090°C Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60nS Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.05% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) Dimensions (W x H x D): 63x198x100mm Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) DC current measuring accuracy: ±(0.2% + 4 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Weight with battery: 700g Display parameters: (6000/20000) Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-374 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Test: diodes Related items: POM-5913; POM-6173A; POM-7519A Software: Fluke Connect Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 100mA...600A AC current measuring range: 100mA...600A AC voltage measuring range: 100mV...600V Resistance measuring range: 100mΩ...600Ω; 6kΩ DC voltage measuring range: 100mV...600V Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-375 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Test: diodes Related items: POM-5913; POM-6173A; POM-7519A Software: Fluke Connect Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 100mA...600A AC current measuring range: 100mA...600A AC voltage measuring range: 0.1mV...1kV Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ DC voltage measuring range: 100mV...1kV Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +12 |
FLUKE-376 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Standard equipment: case; flexible current probe; FLK-TL75 test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5913; POM-6173A; POM-7519A Software: Fluke Connect Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 1...1000µF DC current measuring range: 100mA...1kA AC current measuring range: 100mA...1kA AC voltage measuring range: 100mV...1kV Resistance measuring range: 0.1...60kΩ DC voltage measuring range: 0.1mV...1kV Frequency measuring range: 100mHz...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 34mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 246x83x43mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) CF crest factor: 2.5 @ 600A Pollution degree: 2 Weight with battery: 388g Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless |
auf Bestellung 42 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-902 FC | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Power supply: battery LR6 AA 1,5V x2 Interface: Bluetooth Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads Conform to the norm: CAT III 600V; EN 61010 Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip Kind of meter: digital; pincers type Type of meter: multifunction Software: Fluke Connect Related items: POM-5900A/POM; POM-5907A; POM-6041B Kind of display used: LCD Illumination: yes Resistance to: shockproof True effective value measurement: True RMS AC Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 0.1...200µA AC current measuring range: 100mA...600A AC voltage measuring range: 100mV...600V Resistance measuring range: 100mΩ...999Ω; 9.999kΩ Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1.5%+5 digit) DC voltage measuring range: 100mV...600V Dimensions: 240x80x40mm DC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring accuracy: ±(1% + 5 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) DC current measuring accuracy: ±(1% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Weight with battery: 310g Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication; <30Ω Measuring instruments application: air conditioning; heating industry; ventilation |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +7 |
FLUKE-323 | FLUKE |
Category: Meters and AC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30 Display parameters: 3,5 digit Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; DC voltage; resistance Continuity test: acoustic indication; <70Ω Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Standard equipment: case; test leads Conform to the norm: CAT III 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A IP rating: IP30 Kind of display used: LCD True effective value measurement: True RMS AC current measuring range: 100mA...400A AC voltage measuring range: 100mV...400V; 600V Resistance measuring range: 100mΩ...400Ω; 4kΩ DC voltage measuring range: 100mV...400V; 600V Current measuring resolution: 0.1A DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1%+5 digit) Dimensions: 207x75x34mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Bandwidth for AC current measurements: 45...400Hz Bandwidth for AC voltage measurements: 45...400Hz Weight with battery: 265g Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator |
auf Bestellung 57 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +9 |
FLUKE-325 | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD Display parameters: 3,5 digit Optional equipment: FLK-TL223 accessory set Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Continuity test: acoustic indication; <30Ω Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Power supply: battery LR03 AAA 1,5V x2 Standard equipment: case; test leads Conform to the norm: CAT III 600V; EN 61010 Kind of meter: digital; pincers type Type of meter: multifunction Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A IP rating: IP30 Kind of display used: LCD Illumination: yes True effective value measurement: True RMS Capacitance measuring range: 0.1...100µF; 1mF DC current measuring range: 10mA...40A; 400A AC current measuring range: 10mA...40A; 400A AC voltage measuring range: 100mV...400V; 600V Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ DC voltage measuring range: 100mV...400V; 600V Frequency measuring range: 5...500Hz Current measuring resolution: 10mA DC voltage measuring accuracy: ±(1% + 5 digit) Max. diameter of measured cable: 30mm Resistance measuring accuracy: ±(1%+5 digit) DC current measuring accuracy: ±(2% + 5 digit) Dimensions: 207x75x34mm AC voltage measuring accuracy: ±(1.5% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) Capacitance measuring accuracy: ±(1%+ 4 digit) Bandwidth for AC current measurements: 45...400Hz Bandwidth for AC voltage measurements: 45...400Hz Weight with battery: 283g Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator |
auf Bestellung 61 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +6 |
FLUKE-378 FC/E | FLUKE |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD Type of meter: multifunction Kind of meter: digital; pincers type Max. diameter of measured cable: 34mm Kind of display used: LCD DC current measuring range: 100mA...999.9A AC current measuring range: 100mA...999.9A Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless DC current measuring accuracy: ±(2% + 5 digit) AC current measuring accuracy: ±(2% + 5 digit) DC voltage measuring range: 600V; 1kV DC voltage measuring accuracy: ±(1% + 5 digit) AC voltage measuring range: 600V; 1kV AC voltage measuring accuracy: ±(1.5% + 5 digit) Resistance measuring accuracy: ±(1%+5 digit) True effective value measurement: True RMS Resistance measuring range: 600Ω; 6kΩ; 60kΩ Capacitance measuring range: 0.1...100µF; 1mF Capacitance measuring accuracy: ±(1%+ 4 digit) Frequency measuring range: 5...500Hz Frequency measuring accuracy: ±(0.5%+5 digit) Continuity test: acoustic indication; <30Ω Test: diodes CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A Pollution degree: 2 Dimensions: 274x86x47mm Weight with battery: 463g Power supply: battery LR6 AA 1,5V x2 Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Interface: Bluetooth Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Illumination: yes Software: Fluke Connect |
auf Bestellung 19 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
TL71-1 | FLUKE |
Category: Test Leads - Sets Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2 Type of test accessories: test leads Rated voltage: 1kV Colour: red and black Test lead configuration: banana plug 4mm; probe tip Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Wire insulation material: silicone Kit contents: test leads x2 Cable length: 1.5m Current rating: 10A |
auf Bestellung 64 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
TP40 | FLUKE |
Category: Probes - Test PlugsDescription: Set of measuring probes; 60VDC; Kit: test probes x5 Type of test accessories: set of measuring probes Kit contents: test probes x5 Rated voltage: 60V DC Related items: FLK-TL222; FLK-TL224 |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +10 |
FLUKE-289/FVF/EUR | FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; Software: Fluke View Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Type of meter: digital multimeter Software: Fluke View |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +14 |
FLK-289/FVF/IR3000 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; Software: Fluke View Forms Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Type of meter: digital multimeter Software: Fluke View Forms |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +3 |
I2000 FLEX | FLUKE |
Category: Meters and AC Clamp ProbesDescription: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V Conform to the norm: CAT III 600V; EN 61010 Kind of display used: LCD True effective value measurement: True RMS AC AC current measuring range: 1...20A; 200A; 2kA Max. diameter of measured cable: 178mm Cable length: 0.5m AC current measuring accuracy: ±1% Bandwidth for AC current measurements: 10Hz...20kHz Weight with battery: 420g Max. operating voltage: 600V Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A) Display parameters: (3000) Measurement: AC current Type of test accessories: AC current clamp adapter Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs Power supply: battery LR6 AA 1,5V x2 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Standard equipment: BNC to banana plug adapter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
BP120MH | FLUKE |
Category: Accessories for Oscilloscopes - Others Description: Rechargeable battery; 4.8V; 3000mAh Type of test accessories: rechargeable battery Related items: FLK-43B; FLK-123 Capacity: 3Ah Rated voltage: 4.8V |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +4 |
FLK-TIS55+ 9HZ | FLUKE |
Category: Fluke Infrared CamerasDescription: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54 Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 256x192 Temperature measuring range: -20...550°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 28° horizontal x 20° vertical IP rating: IP54 Power supply: rechargeable battery Li-Ion x1 Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable Thermal sensitivity (NETD): 40mK Interface: LAN; USB; WiFi Resistance to: fall from 2m height Battery/ rechargeable battery: rechargeable battery Li-Ion x1 Display resolution: 320x240 Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF Measurement: temperature Touchpad: yes Operating temperature: -10...50°C Three-dimensional resolution: 1.91mrad Dimensions: 267x101x145mm Focusing: manual Measuring unit: °C; °F Software: download from manufacturers website; Fluke Connect |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLK-TIS60+ 9HZ | FLUKE |
Category: Fluke Infrared CamerasDescription: Infrared camera; LCD 3,5"; 320x240; -20÷400°C; Focus: FocusFree Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 320x240 Temperature measuring range: -20...400°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 34.1° horizontal x 25.6° vertical Focusing: FocusFree IP rating: IP54 Dimensions: 26.7x10.1x14.5mm Power supply: rechargeable battery Li-Ion 7,4V x2 Measuring instrument features: adjustable display illumination; adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC Standard equipment: battery charger; case; hard case; microSD memory card; power supply; USB cable Three-dimensional resolution: 1.86mrad Thermal sensitivity (NETD): <0.045 @ 30°C Resistance to: fall from 2m height Measurement: temperature Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V x2 Display resolution: 320x240 Related items: FLK-TI-SBP3 Measuring unit: °C; °F Interface: Bluetooth; LAN; USB; WiFi |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||
![]() +4 |
FLK-TIS75+ 9HZ | FLUKE |
Category: Fluke Infrared CamerasDescription: Infrared camera; LCD 3,5"; 384x288; -20÷550°C; Focus: manual; IP54 Type of meter: infrared camera Kind of display used: LCD 3,5" Camera resolution: 384x288 Temperature measuring range: -20...550°C Temperature measurement accuracy: ±2%; ±2°C Field of observation: 42° horizontal x 30° vertical IP rating: IP54 Power supply: rechargeable battery Li-Ion x1 Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC Standard equipment: battery charger; carrying strap; case; hard case; microSD 4GB memory card; power supply; USB cable Thermal sensitivity (NETD): 40mK Interface: LAN; USB; WiFi Resistance to: fall from 2m height Related items: FLK-TI-SBP3 Display resolution: 320x240 Supported formats: BMP; GIF; IS2; IS3; JPEG; PNG; TIFF Measurement: temperature Touchpad: yes Operating temperature: -10...50°C Three-dimensional resolution: 1.91mrad Dimensions: 267x101x145mm Focusing: manual Measuring unit: °C; °F Software: download from manufacturers website; Fluke Connect |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
C25 | FLUKE |
Category: Bags & Soft Cases Description: Cover; 218x128x64mm Dimensions: 218x128x64mm Related items: FLK-27YEL; FLK-51-2-50HZ; FLK-52-2-50HZ; FLK-53-2-50HZ; FLK-54-2-50HZ; FLK-77-4; FLK-83V; FLK-87V; FLK-88V; FLK-114; FLK-115; FLK-116; FLK-117; FLK-175EGFID; FLK-177EGFID; FLK-179EGFID; FLK-712; FLK-714; FLK-715; FLK-717; FLK-724; FLK-725; FLK-726; FLK-787; FLK-789; FLK-922; FLK-971; FLK-1503; FLK-1507; FLK-1577; FLK-1587; FLK-9040; FLK-9062 Type of test accessories: cover |
auf Bestellung 7 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +6 |
FLUKE-87-5/E2K/EUR | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter Battery/ rechargeable battery: battery 6F22 9V x1 Standard equipment: digital multimeter FLK-87V; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; FLK-TL224 silicone test leads set; magnetic hanging strap FLK-TOOLPAK; test probes; test probes FLK-AC220 SureGrip Type of meter: digital multimeter Related items: POM-4408; POM-5519A; POM-5673B |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +12 |
FLUKE-1587/MDT FC | FLUKE |
Category: Multimeters - SetsDescription: Measuring kit: multimeters Related items: POM-5906A; POM-5907A; POM-6041B Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Type of measuring kit: multimeters Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
![]() +2 |
FLUKE-705 | FLUKE |
Category: CalibratorsDescription: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA Measurement: DC current; DC voltage Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221 Kind of display used: LCD Kind of calibrator: loop Type of meter: calibrator Power supply: battery 6F22 9V x1 Current source accuracy: ±(0,025% + 2 digits) Current source: 0...20mA; 4...20mA DC current measuring range: 0.001...24mA DC voltage measuring range: 1mV...28V DC voltage measuring accuracy: ±(0.025% + 1 digit) DC current measuring accuracy: ±(0.025% + 2 digit) Dimensions: 201x98x52mm Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
| FLUKE-116 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Standard equipment: FLK-TL75 test leads
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA
AC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication; <20Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Standard equipment: FLK-TL75 test leads
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA
AC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Diode test: 1.2mA @2.7V
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
Temperature measurement accuracy: ±(0.1% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
auf Bestellung 28 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 415.01 EUR |
| FLUKE-117 EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Battery/ rechargeable battery: battery 6LR61 9V x1
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Type of meter: digital multimeter
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC current measuring range: 1mA...6A; 10A; (20A <30s)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
auf Bestellung 43 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 418.1 EUR |
| FLUKE-175 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.15% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
auf Bestellung 80 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 437.05 EUR |
| FLUKE-177 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: FLK-TL75 test leads
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1.1mA @2.4V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Bargraph: 33 segm. 40x/s
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
auf Bestellung 76 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 514.66 EUR |
| FLUKE-179 EGFID |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Continuity test: acoustic indication; <25Ω
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Continuity test: acoustic indication; <25Ω
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-TL75 test leads
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
Manufacturer series: Fluke 170
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Temperature measuring range: -40...400°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1.1mA @2.4V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 89x190x45mm
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 420g
Display parameters: 3,75 digit (6000)
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 84 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 617.59 EUR |
| FLUKE-1577 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(1.2%+2 digit)
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Weight with battery: 550g
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
DC current measuring range: 10µA...60mA; 400mA
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Kind of display used: LCD
Display parameters: (6000)
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Resistance measuring accuracy: ±(1.2%+2 digit)
Continuity test: acoustic indication; <25Ω
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Weight with battery: 550g
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Illumination: yes
Dimensions (W x H x D): 100x203x50mm
DC current measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Test voltage: 500V; 1kV
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
IP rating: IP40
DC current measuring range: 10µA...60mA; 400mA
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1099.51 EUR |
| 2824477 |
Hersteller: FLUKE
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
Category: Accessories - Others
Description: Battery container
Type of test accessories: battery container
Related items: FLK-289
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 86.69 EUR |
| FLK-3000FC/EDA2 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Standard equipment: FLK-3000FC wireless multimeter; FLK-C35 soft cover; manual (CD); test leads FLK-TL-224; test probes FLK-AC280 SureGrip; test probes FLK-TL910
Type of meter: digital multimeter
Related items: POM-5677B; POM-5899A; POM-7519A
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 707.06 EUR |
| FLUKE-179/EDA2/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Category: Portable digital multimeters
Description: Digital multimeter
Type of meter: digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 693.78 EUR |
| FLUKE-179/MAG2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Related items: POM-5904A/POM; POM-6343; POM-7519A
Category: Portable digital multimeters
Description: Digital multimeter
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Type of meter: digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Related items: POM-5904A/POM; POM-6343; POM-7519A
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 581.55 EUR |
| FLUKE-T110 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Type of tester: electrical
Kind of display used: LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 270g
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 39 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 135.39 EUR |
| FLUKE T110/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 100÷690VAC; 0÷400Hz; IP64; 0Ω÷400kΩ
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 135.82 EUR |
| FLUKE-T90 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs; 12÷690VAC; 0÷400Hz; IP54; 0Ω÷400kΩ
Type of tester: electrical
Measuring instrument features: checks AC/DC voltage levels (12...690V) even at discharged batteries; polarity identification; polarization indicator
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Additional functions: illumination lamp
Conform to the norm: CAT II 690V; CAT III 600V; EN 61010
IP rating: IP54
Kind of display used: LEDs
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 245x64x28mm
DC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring accuracy: ±(3% + 5 digit)
Phase-to-phase voltage range for phase sequence indication: 12...690V AC
Weight with battery: 180g
Measurement: AC voltage; DC voltage
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
auf Bestellung 50 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 96.27 EUR |
| FLUKE-T130 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 24 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 203.78 EUR |
| FLUKE T130/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 203.69 EUR |
| FLUKE-T150 |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
Resistance measuring range: 1...1999Ω
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage; resistance
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 6÷690VAC; 0÷400Hz; IP64
Type of tester: electrical
Kind of display used: LCD; LEDs
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; possibility to turning off a buzzer; RCD triggering via a button
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Additional functions: illumination lamp
IP rating: IP64
Bandwidth for AC voltage measurements: 0...400Hz
Body dimensions: 255x78x35mm
Resistance measuring range: 1...1999Ω
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 6...690V AC
Weight with battery: 270g
Display parameters: 3,5 digit
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
Measurement: AC voltage; DC voltage; resistance
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
auf Bestellung 45 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 234.98 EUR |
| FLUKE T150/VDE |
![]() |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Resistance measuring range: 1...1999Ω
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage; resistance
Category: Indicators, Voltage & Continuity Testers
Description: Tester: electrical; LEDs,LCD; 3,5 digit; 100÷690VAC; 0÷400Hz; IP64
Conform to the norm: CAT III 690V; CAT IV 600V; EN 61010
Kind of display used: LCD; LEDs
IP rating: IP64
Additional functions: illumination lamp
Type of tester: electrical
Display parameters: 3,5 digit
Bandwidth for AC voltage measurements: 0...400Hz
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Body dimensions: 255x78x35mm
Power supply: battery LR03 AAA 1,5V x2
Resistance measuring range: 1...1999Ω
Continuity test: acoustic indication; optical indication; 0Ω...400kΩ
DC voltage measuring accuracy: ±(3% + 5 digit)
AC voltage measuring accuracy: ±(3% + 5 digit)
Resistance measuring accuracy: ±(5%+10 digit)
DC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
AC voltage measuring range: 6V; 12V; 24V; 50V; 120V; 230V; 400V; 690V
Phase-to-phase voltage range for phase sequence indication: 100...690V AC
Measuring instrument features: checks AC/DC voltage levels (6...690V) even at discharged batteries; HOLD function; indicates phase sequence; polarity identification; polarization indicator; RCD triggering via a button
Weight with battery: 270g
Measurement: AC voltage; DC voltage; resistance
auf Bestellung 29 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 235.09 EUR |
| FLUKE-787B |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1904.69 EUR |
| FLUKE-789/E |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Interface: IrDA
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Software: Fluke Connect (FLK-IR3000FC)
Kind of display used: LCD
DC current measuring range: 1µA...30mA; 1A
AC current measuring range: 0.001mA...1A
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(1.2% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: 0% or 100% of signal value (4mA, 20mA) source function; 24V loop supply voltage; automatic and manual setting of step function; HART range with loop and built-in 250Ω resistor; HOLD function; impact resistant holster; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2250.05 EUR |
| FLUKE-88-5/A KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 0...10000µF
DC current measuring range: 0...10A
AC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; VDC: 0÷1kV; VAC: 0÷1kV; I DC: 0÷10A; 0÷50MΩ
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: automotive back probe pins 2pcs; crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; hard case FLK-800; holster; insulation piercing clip; magnetic hanging strap FLK-TOOLPAK; probe FLK-RPM80; test leads FLK-TL224 SureGrip; test probes FLK-TP220
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
Kind of display used: LCD
True effective value measurement: True RMS AC
Bargraph: yes
Temperature measuring range: -200...1090°C
Capacitance measuring range: 0...10000µF
DC current measuring range: 0...10A
AC current measuring range: 0...10A
DC voltage measuring range: 0...1kV
AC voltage measuring range: 0...1kV
Frequency measuring range: 0...200kHz
Resistance measuring range: 0...50MΩ
Diode test: 3V
Dimensions (W x H x D): 86x186x32mm
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEAN/REL function; PEAK HOLD function; settable MIN/MAX alarm thresholds
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1223.79 EUR |
| FLUKE-279FC/IFLEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Continuity test: acoustic indication; <25Ω
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Diode test: 2V
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Continuity test: acoustic indication; <25Ω
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter with infrared camera
Connectors for the country: Europe; Great Britain
Focusing: focus free
Non-contact temperature measuring range: -10...200°C
Capacitance measuring range: 1000nF...9999µF
AC current measuring range: 100mA...999.9A; 2.5kA
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Resistance measuring range: 600Ω...50MΩ
Diode test: 2V
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
Refresh rate: 8Hz
Camera resolution: 80x60
Emissivity value: 0,95 (fixed)
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-3000FC |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; VDC: 600mV,6V,60V,600V,1kV
IP rating: IP54
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Software: compatible Android; Fluke Connect
Type of meter: digital multimeter
Related items: FLK-A3001FC-KITCAR; POM-5677B; POM-5899A; POM-7519A
Kind of display used: LCD
True effective value measurement: True RMS
Capacitance measuring range: 1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 60mA; 400mA
DC current measuring range: 60mA; 400mA
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Diode test: 2V
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Frequency measuring range: 9.999Hz; 99.99Hz; 999.9Hz; 99.99kHz
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.5%+1 digit)
Dimensions (W x H x D): 93x207x48mm
DC current measuring accuracy: ±(0.5% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Weight with battery: 340g
Measuring instrument features: 20m range; auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clips FLK-AC175; FLK-TL175 test leads
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-1587 T |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Type of meter: digital multimeter
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Kind of display used: LCD
Optional equipment: FLK-C25 soft cover
IP rating: IP40
True effective value measurement: True RMS
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring accuracy: ±(0.9%+2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Test voltage: 50V; 100V
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Continuity test: acoustic indication; <25Ω
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1217.19 EUR |
| FLUKE-123B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 20MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2804.46 EUR |
| FLUKE-123B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Kind of display used: colour; LCD TFT 5,7"
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Resistance measuring accuracy: ±(0.6%+5 digit)
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Related items: POM-72941; POM-72942
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Band: 20MHz
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Software: Fluke View
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Dimensions: 259x132x55mm
Number of channels: 2
Display resolution: 640x480
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Kind of display used: colour; LCD TFT 5,7"
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Resistance measuring accuracy: ±(0.6%+5 digit)
Diode test: 0.5mA @2.8V
Continuity test: acoustic indication
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Related items: POM-72941; POM-72942
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Band: 20MHz
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Software: Fluke View
Connectors for the country: Europe
Manufacturer series: FLUKE 120B
IP rating: IP51
Additional functions: multimeter
Type of oscilloscope: scopemeter
Time base: 20n...60s/div
Dimensions: 259x132x55mm
Number of channels: 2
Display resolution: 640x480
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLUKE-124B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 3422.58 EUR |
| FLUKE-124B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4183.61 EUR |
| FLUKE-125B/EU |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Related items: POM-72941; POM-72942
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4019.54 EUR |
| FLUKE-125B/EU/S |
![]() |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
IP rating: IP51
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Kind of display used: colour; LCD TFT 5,7"
Connectors for the country: Europe
Software: Fluke View
Additional functions: multimeter
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Type of oscilloscope: scopemeter
Time base: 10n...60s/div
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Dimensions: 259x132x55mm
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(0.6%+5 digit)
Number of channels: 2
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
Display resolution: 640x480
Band: 40MHz
Manufacturer series: FLUKE 120B
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Sampling: 40Msps
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Continuity test: acoustic indication
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 4861.79 EUR |
| FLUKE-1587 FC |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Continuity test: acoustic indication; <25Ω
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Weight with battery: 550g
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Optional equipment: FLK-C25 soft cover
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Continuity test: acoustic indication; <25Ω
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP40
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Temperature measuring range: -40...537°C
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 10µA...60mA; 400mA
AC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Diode test: 1mA @6V
Frequency measuring accuracy: ±(0.1%+1 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Dimensions (W x H x D): 100x203x50mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Weight with battery: 550g
Test voltage: 500V
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Optional equipment: FLK-C25 soft cover
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
auf Bestellung 14 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1319.6 EUR |
| FLK-115/TLK-225-1 |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Standard equipment: digital multimeter FLK-115; FLK-TL75 test leads; FLK-TLK225 set
Type of meter: digital multimeter
Power supply: battery 6LR61 9V x1
Battery/ rechargeable battery: battery 6LR61 9V x1
Conform to the norm: CAT III 600V; EN 61010
Manufacturer series: Fluke 110
Kind of display used: LCD
True effective value measurement: True RMS AC
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
AC current measuring range: 1mA...6A; 10A; (20A <30s)
DC current measuring range: 1mA...6A; 10A; 20A < 30s
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Diode test: 1.2mA @2.7V
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Frequency measuring accuracy: ±(0.1%+2 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Dimensions (W x H x D): 84x167x46mm
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
Pollution degree: 2
Bargraph: 33 segm. 32x/s
Weight with battery: 550g
Display parameters: 3,75 digit (6000)
Optional equipment: FLK-80BK-A drop-like K-type probe; FLK-80PJ-EXT drop-like J-type probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <20Ω
Measuring instrument features: auto and manual ranging; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; removable holster
auf Bestellung 118 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 399.83 EUR |
| FLUKE-27II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1018.39 EUR |
| FLUKE-28II/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1011.75 EUR |
| FLUKE-28IIEX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR03 AAA 1,5V x3
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000/19999)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: test leads
Power supply: battery LR03 AAA 1,5V x3
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
Duty cycle factor: 0...99.9%
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @2.8V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 100x198x63.5mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 517g
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Display parameters: (6000/19999)
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type probe; FLK-80PK-1 drop-like K-type probe; FLK-80PK-8 drop-like K-type probe; FLK-80PK-9 drop-like K-type probe; FLK-80PK-27 drop-like K-type probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 2424.36 EUR |
| FLUKE-381 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-TL175 test leads; FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Power supply: battery LR03 AAA 1,5V x5
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...600V; 1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...600V; 1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Body dimensions: 277x88x43mm
DC voltage measuring accuracy: ±(1.5% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Measuring instrument features: automatic power-off; flexible current probe; HOLD function; MIN/MAX/MEDIUM function; wireless display (range up to 10m)
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1051.22 EUR |
| FLUKE-83-5/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 725.12 EUR |
| FLUKE-87-5/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 95x200x48mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 20 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 752.49 EUR |
| FLUKE-87V-MAX |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 967.38 EUR |
| FLUKE-87V-MAX/E2 KIT |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1140.63 EUR |
| FLK-87VMAX-PVLEAD1 |
Hersteller: FLUKE
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Category: PV and EVSE Testers and Meters
Description: Meter: digital multimeter; VAC accuracy: ±(0.7%+4digit); IP67
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Continuity test: acoustic indication
Standard equipment: crocodile clip FLK-AC175 x2; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; test leads MC4
Power supply: battery LR6 AA 1,5V x3
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP67
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Temperature measuring range: -200...1090°C
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60nS
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.05% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Dimensions (W x H x D): 63x198x100mm
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
DC current measuring accuracy: ±(0.2% + 4 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Weight with battery: 700g
Display parameters: (6000/20000)
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1022.42 EUR |
| FLUKE-374 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...600Ω; 6kΩ
DC voltage measuring range: 100mV...600V
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 670.24 EUR |
| FLUKE-375 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Test: diodes
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 100mA...600A
AC current measuring range: 100mA...600A
AC voltage measuring range: 0.1mV...1kV
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
DC voltage measuring range: 100mV...1kV
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; transfer measurement data wireless
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 785.93 EUR |
| FLUKE-376 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Optional equipment: FLK-C43 soft cover; FLK-I2500-10 flexible current probe; FLK-I2500-18 flexible current probe
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: case; flexible current probe; FLK-TL75 test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5913; POM-6173A; POM-7519A
Software: Fluke Connect
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 1...1000µF
DC current measuring range: 100mA...1kA
AC current measuring range: 100mA...1kA
AC voltage measuring range: 100mV...1kV
Resistance measuring range: 0.1...60kΩ
DC voltage measuring range: 0.1mV...1kV
Frequency measuring range: 100mHz...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 34mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 246x83x43mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
CF crest factor: 2.5 @ 600A
Pollution degree: 2
Weight with battery: 388g
Measuring instrument features: flexible current probe up to 2500A; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEDIUM function; transfer measurement data wireless
auf Bestellung 42 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 852.91 EUR |
| FLUKE-902 FC |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Type of meter: multifunction
Software: Fluke Connect
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Kind of display used: LCD
Illumination: yes
Resistance to: shockproof
True effective value measurement: True RMS AC
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 0.1...200µA
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1.5%+5 digit)
DC voltage measuring range: 100mV...600V
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Weight with battery: 310g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Power supply: battery LR6 AA 1,5V x2
Interface: Bluetooth
Standard equipment: FLK-80BK-A drop-like K-type probe; FLK-C33 soft cover; FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Optional equipment: cover FLK-H3; crocodile clip FLK-AC175; crocodile clip FLK-AC220; test leads FLK-TL224 SureGrip
Kind of meter: digital; pincers type
Type of meter: multifunction
Software: Fluke Connect
Related items: POM-5900A/POM; POM-5907A; POM-6041B
Kind of display used: LCD
Illumination: yes
Resistance to: shockproof
True effective value measurement: True RMS AC
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 0.1...200µA
AC current measuring range: 100mA...600A
AC voltage measuring range: 100mV...600V
Resistance measuring range: 100mΩ...999Ω; 9.999kΩ
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1.5%+5 digit)
DC voltage measuring range: 100mV...600V
Dimensions: 240x80x40mm
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring accuracy: ±(1% + 5 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
DC current measuring accuracy: ±(1% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Weight with battery: 310g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; MIN/MAX function
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <30Ω
Measuring instruments application: air conditioning; heating industry; ventilation
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 525.52 EUR |
| FLUKE-323 |
![]() |
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; 3,5 digit; IP30
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; DC voltage; resistance
Continuity test: acoustic indication; <70Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS
AC current measuring range: 100mA...400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ
DC voltage measuring range: 100mV...400V; 600V
Current measuring resolution: 0.1A
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 265g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
auf Bestellung 57 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 209.9 EUR |
| FLUKE-325 |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 30mm; LCD
Display parameters: 3,5 digit
Optional equipment: FLK-TL223 accessory set
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Continuity test: acoustic indication; <30Ω
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Power supply: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
Kind of meter: digital; pincers type
Type of meter: multifunction
Related items: POM-5900A/POM; POM-5904A/POM; POM-7519A
IP rating: IP30
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Capacitance measuring range: 0.1...100µF; 1mF
DC current measuring range: 10mA...40A; 400A
AC current measuring range: 10mA...40A; 400A
AC voltage measuring range: 100mV...400V; 600V
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 40kΩ
DC voltage measuring range: 100mV...400V; 600V
Frequency measuring range: 5...500Hz
Current measuring resolution: 10mA
DC voltage measuring accuracy: ±(1% + 5 digit)
Max. diameter of measured cable: 30mm
Resistance measuring accuracy: ±(1%+5 digit)
DC current measuring accuracy: ±(2% + 5 digit)
Dimensions: 207x75x34mm
AC voltage measuring accuracy: ±(1.5% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
Capacitance measuring accuracy: ±(1%+ 4 digit)
Bandwidth for AC current measurements: 45...400Hz
Bandwidth for AC voltage measurements: 45...400Hz
Weight with battery: 283g
Measuring instrument features: automatic power-off; ergonomic body shape enables one-hand operation; HOLD function; low battery indicator
auf Bestellung 61 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 367.15 EUR |
| FLUKE-378 FC/E |
![]() |
Hersteller: FLUKE
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 34mm
Kind of display used: LCD
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 600V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 600V; 1kV
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 0.1...100µF; 1mF
Capacitance measuring accuracy: ±(1%+ 4 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Continuity test: acoustic indication; <30Ω
Test: diodes
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Dimensions: 274x86x47mm
Weight with battery: 463g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Interface: Bluetooth
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Software: Fluke Connect
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 34mm; LCD
Type of meter: multifunction
Kind of meter: digital; pincers type
Max. diameter of measured cable: 34mm
Kind of display used: LCD
DC current measuring range: 100mA...999.9A
AC current measuring range: 100mA...999.9A
Measuring instrument features: automatic power-off; contactless voltage measurement; flexible current probe up to 2500A; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; power quality indicator shows whether a problem is in the equipment or the power line; transfer measurement data wireless
DC current measuring accuracy: ±(2% + 5 digit)
AC current measuring accuracy: ±(2% + 5 digit)
DC voltage measuring range: 600V; 1kV
DC voltage measuring accuracy: ±(1% + 5 digit)
AC voltage measuring range: 600V; 1kV
AC voltage measuring accuracy: ±(1.5% + 5 digit)
Resistance measuring accuracy: ±(1%+5 digit)
True effective value measurement: True RMS
Resistance measuring range: 600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 0.1...100µF; 1mF
Capacitance measuring accuracy: ±(1%+ 4 digit)
Frequency measuring range: 5...500Hz
Frequency measuring accuracy: ±(0.5%+5 digit)
Continuity test: acoustic indication; <30Ω
Test: diodes
CF crest factor: 1.42 @ 1kA; 2.5 @ 600A; 3 @ 500A
Pollution degree: 2
Dimensions: 274x86x47mm
Weight with battery: 463g
Power supply: battery LR6 AA 1,5V x2
Standard equipment: case; crocodile clip FLK-AC285; FLK-I2500-18 flexible current probe; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes TP175
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; inrush current; resistance
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Interface: Bluetooth
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Illumination: yes
Software: Fluke Connect
auf Bestellung 19 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 988.16 EUR |
| TL71-1 |
Hersteller: FLUKE
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Type of test accessories: test leads
Rated voltage: 1kV
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Kit contents: test leads x2
Cable length: 1.5m
Current rating: 10A
Category: Test Leads - Sets
Description: Test leads; Urated: 1kV; Inom: 10A; Len: 1.5m; test leads x2
Type of test accessories: test leads
Rated voltage: 1kV
Colour: red and black
Test lead configuration: banana plug 4mm; probe tip
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Wire insulation material: silicone
Kit contents: test leads x2
Cable length: 1.5m
Current rating: 10A
auf Bestellung 64 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 57.92 EUR |
| TP40 |
![]() |
Hersteller: FLUKE
Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Type of test accessories: set of measuring probes
Kit contents: test probes x5
Rated voltage: 60V DC
Related items: FLK-TL222; FLK-TL224
Category: Probes - Test Plugs
Description: Set of measuring probes; 60VDC; Kit: test probes x5
Type of test accessories: set of measuring probes
Kit contents: test probes x5
Rated voltage: 60V DC
Related items: FLK-TL222; FLK-TL224
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 83.68 EUR |
| FLUKE-289/FVF/EUR |
![]() |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Type of meter: digital multimeter
Software: Fluke View
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Type of meter: digital multimeter
Software: Fluke View
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1436.65 EUR |
| FLK-289/FVF/IR3000 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Type of meter: digital multimeter
Software: Fluke View Forms
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-289; FLK-80BK-A drop-like K-type probe; FLK-IR3000FC; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Type of meter: digital multimeter
Software: Fluke View Forms
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1664.43 EUR |
| I2000 FLEX |
![]() |
Hersteller: FLUKE
Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
True effective value measurement: True RMS AC
AC current measuring range: 1...20A; 200A; 2kA
Max. diameter of measured cable: 178mm
Cable length: 0.5m
AC current measuring accuracy: ±1%
Bandwidth for AC current measurements: 10Hz...20kHz
Weight with battery: 420g
Max. operating voltage: 600V
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
Display parameters: (3000)
Measurement: AC current
Type of test accessories: AC current clamp adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Standard equipment: BNC to banana plug adapter
Category: Meters and AC Clamp Probes
Description: AC current clamp adapter; LCD; (3000); Øcable: 178mm; ±1%; 600V
Conform to the norm: CAT III 600V; EN 61010
Kind of display used: LCD
True effective value measurement: True RMS AC
AC current measuring range: 1...20A; 200A; 2kA
Max. diameter of measured cable: 178mm
Cable length: 0.5m
AC current measuring accuracy: ±1%
Bandwidth for AC current measurements: 10Hz...20kHz
Weight with battery: 420g
Max. operating voltage: 600V
Output signal: 1mV/1A (for 2000A); 10mV/1A (for 200A)
Display parameters: (3000)
Measurement: AC current
Type of test accessories: AC current clamp adapter
Measuring instrument features: flexible current probe; permanently connected test leads; protected banana plugs
Power supply: battery LR6 AA 1,5V x2
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Standard equipment: BNC to banana plug adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 611.34 EUR |
| BP120MH |
Hersteller: FLUKE
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
Category: Accessories for Oscilloscopes - Others
Description: Rechargeable battery; 4.8V; 3000mAh
Type of test accessories: rechargeable battery
Related items: FLK-43B; FLK-123
Capacity: 3Ah
Rated voltage: 4.8V
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-TIS55+ 9HZ |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 256x192; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 256x192
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 28° horizontal x 20° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: 4GB SD memory card; carrying strap; case; hard case; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Battery/ rechargeable battery: rechargeable battery Li-Ion x1
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 3964.16 EUR |
| FLK-TIS60+ 9HZ |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 320x240; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 320x240
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 34.1° horizontal x 25.6° vertical
Focusing: FocusFree
IP rating: IP54
Dimensions: 26.7x10.1x14.5mm
Power supply: rechargeable battery Li-Ion 7,4V x2
Measuring instrument features: adjustable display illumination; adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; case; hard case; microSD memory card; power supply; USB cable
Three-dimensional resolution: 1.86mrad
Thermal sensitivity (NETD): <0.045 @ 30°C
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V x2
Display resolution: 320x240
Related items: FLK-TI-SBP3
Measuring unit: °C; °F
Interface: Bluetooth; LAN; USB; WiFi
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 320x240; -20÷400°C; Focus: FocusFree
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 320x240
Temperature measuring range: -20...400°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 34.1° horizontal x 25.6° vertical
Focusing: FocusFree
IP rating: IP54
Dimensions: 26.7x10.1x14.5mm
Power supply: rechargeable battery Li-Ion 7,4V x2
Measuring instrument features: adjustable display illumination; adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; case; hard case; microSD memory card; power supply; USB cable
Three-dimensional resolution: 1.86mrad
Thermal sensitivity (NETD): <0.045 @ 30°C
Resistance to: fall from 2m height
Measurement: temperature
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V x2
Display resolution: 320x240
Related items: FLK-TI-SBP3
Measuring unit: °C; °F
Interface: Bluetooth; LAN; USB; WiFi
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| FLK-TIS75+ 9HZ |
![]() |
Hersteller: FLUKE
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 384x288; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 384x288
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 42° horizontal x 30° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; carrying strap; case; hard case; microSD 4GB memory card; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Related items: FLK-TI-SBP3
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; IS3; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
Category: Fluke Infrared Cameras
Description: Infrared camera; LCD 3,5"; 384x288; -20÷550°C; Focus: manual; IP54
Type of meter: infrared camera
Kind of display used: LCD 3,5"
Camera resolution: 384x288
Temperature measuring range: -20...550°C
Temperature measurement accuracy: ±2%; ±2°C
Field of observation: 42° horizontal x 30° vertical
IP rating: IP54
Power supply: rechargeable battery Li-Ion x1
Measuring instrument features: adjustable emissivity; AutoBlend function; colour alarms; IR-Fusion function to combine thermal and real images; radiometric measurements for detailed temperature analysis; voice and text message recorder; wide palette of colours; wireless communication with PC
Standard equipment: battery charger; carrying strap; case; hard case; microSD 4GB memory card; power supply; USB cable
Thermal sensitivity (NETD): 40mK
Interface: LAN; USB; WiFi
Resistance to: fall from 2m height
Related items: FLK-TI-SBP3
Display resolution: 320x240
Supported formats: BMP; GIF; IS2; IS3; JPEG; PNG; TIFF
Measurement: temperature
Touchpad: yes
Operating temperature: -10...50°C
Three-dimensional resolution: 1.91mrad
Dimensions: 267x101x145mm
Focusing: manual
Measuring unit: °C; °F
Software: download from manufacturers website; Fluke Connect
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 6606.79 EUR |
| C25 |
Hersteller: FLUKE
Category: Bags & Soft Cases
Description: Cover; 218x128x64mm
Dimensions: 218x128x64mm
Related items: FLK-27YEL; FLK-51-2-50HZ; FLK-52-2-50HZ; FLK-53-2-50HZ; FLK-54-2-50HZ; FLK-77-4; FLK-83V; FLK-87V; FLK-88V; FLK-114; FLK-115; FLK-116; FLK-117; FLK-175EGFID; FLK-177EGFID; FLK-179EGFID; FLK-712; FLK-714; FLK-715; FLK-717; FLK-724; FLK-725; FLK-726; FLK-787; FLK-789; FLK-922; FLK-971; FLK-1503; FLK-1507; FLK-1577; FLK-1587; FLK-9040; FLK-9062
Type of test accessories: cover
Category: Bags & Soft Cases
Description: Cover; 218x128x64mm
Dimensions: 218x128x64mm
Related items: FLK-27YEL; FLK-51-2-50HZ; FLK-52-2-50HZ; FLK-53-2-50HZ; FLK-54-2-50HZ; FLK-77-4; FLK-83V; FLK-87V; FLK-88V; FLK-114; FLK-115; FLK-116; FLK-117; FLK-175EGFID; FLK-177EGFID; FLK-179EGFID; FLK-712; FLK-714; FLK-715; FLK-717; FLK-724; FLK-725; FLK-726; FLK-787; FLK-789; FLK-922; FLK-971; FLK-1503; FLK-1507; FLK-1577; FLK-1587; FLK-9040; FLK-9062
Type of test accessories: cover
auf Bestellung 7 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 111.03 EUR |
| FLUKE-87-5/E2K/EUR |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-87V; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; FLK-TL224 silicone test leads set; magnetic hanging strap FLK-TOOLPAK; test probes; test probes FLK-AC220 SureGrip
Type of meter: digital multimeter
Related items: POM-4408; POM-5519A; POM-5673B
Category: Portable digital multimeters
Description: Digital multimeter
Battery/ rechargeable battery: battery 6F22 9V x1
Standard equipment: digital multimeter FLK-87V; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; FLK-TL224 silicone test leads set; magnetic hanging strap FLK-TOOLPAK; test probes; test probes FLK-AC220 SureGrip
Type of meter: digital multimeter
Related items: POM-4408; POM-5519A; POM-5673B
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 898 EUR |
| FLUKE-1587/MDT FC |
![]() |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 1762.96 EUR |
| FLUKE-705 |
![]() |
Hersteller: FLUKE
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Category: Calibrators
Description: Meter: calibrator; loop; VDC: 1mV÷28V; I DC: 0.001÷24mA
Measurement: DC current; DC voltage
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; holster FLK-C10; manufacturer's calibration certificate
Optional equipment: crocodile clip FLK-AC220; FLK-TL81A accessory set; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL75; test leads FLK-TL76; test leads FLK-TL-221
Kind of display used: LCD
Kind of calibrator: loop
Type of meter: calibrator
Power supply: battery 6F22 9V x1
Current source accuracy: ±(0,025% + 2 digits)
Current source: 0...20mA; 4...20mA
DC current measuring range: 0.001...24mA
DC voltage measuring range: 1mV...28V
DC voltage measuring accuracy: ±(0.025% + 1 digit)
DC current measuring accuracy: ±(0.025% + 2 digit)
Dimensions: 201x98x52mm
Measuring instrument features: 24V loop supply voltage; 1000Ω source output at 24mA; automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal; measure, source and simulate current in mA; simultaneously source signal and measure loop current; simultaneous readout in mA and % of range; source and simulate 0-20mA or 4-20mA output signal; Span Check function for checking 0% and 100% of set signal; test in 25% signal steps
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH