| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| CDC640J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type AC Cross section of connecting wires: 1...25mm2 Residual current: 30mA Number of poles: 3+N Current rating: 40A Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Conform to the norm: EN 61008-1 IP rating: IP20 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| CDC663J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20 Type of protection: RCD breaker Kind of circuit breaker: type AC Current rating: 63A Residual current: 30mA Max surge current: 250A Number of poles: 3+N Rated voltage: 230/400V AC Mounting: for DIN rail mounting IP rating: IP20 Cross section of connecting wires: 1...25mm2 Short circuit breaking capacity: 10kA Mechanical durability: 4000 cycles Conform to the norm: EN 61008-1 Trade name: RCD |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| CDF525D | HAGER | CDF525D RCD Circuit Breakers |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CDF540D | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; 240VAC Mounting: for DIN rail mounting IP rating: IP20 Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type F Cross section of connecting wires: 1...25mm2 Residual current: 30mA Number of poles: 1+N Current rating: 40A Rated voltage: 240V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Conform to the norm: EN 61008-1 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| CDF625D | HAGER | CDF625D RCD Circuit Breakers |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CDF640D | HAGER | CDF640D RCD Circuit Breakers |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CDS263D | HAGER | CDS263D RCD Circuit Breakers |
auf Bestellung 4 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CDS440D | HAGER | CDS440D RCD Circuit Breakers |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
CDS463D | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Conform to the norm: EN 61008-1 Trade name: RCD Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Residual current: 30mA Number of poles: 3+N Current rating: 63A Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 6kA Type of protection: RCD breaker |
auf Bestellung 11 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
CDS463D | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Conform to the norm: EN 61008-1 Trade name: RCD Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Residual current: 30mA Number of poles: 3+N Current rating: 63A Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 6kA Type of protection: RCD breaker Anzahl je Verpackung: 1 Stücke |
auf Bestellung 11 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
CEA540J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20 Current rating: 40A IP rating: IP20 Conform to the norm: EN 61008-1 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Residual current: 0.1A Number of poles: 1+N Rated voltage: 240V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
CEA540J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20 Current rating: 40A IP rating: IP20 Conform to the norm: EN 61008-1 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Residual current: 0.1A Number of poles: 1+N Rated voltage: 240V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| CEA640J | HAGER | CEA640J RCD Circuit Breakers |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CFA440J | HAGER | CFA440J RCD Circuit Breakers |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| CFA563J | HAGER | CFA563J RCD Circuit Breakers |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
CFA663J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Current rating: 63A Residual current: 0.3A Number of poles: 3+N Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Conform to the norm: EN 61008-1 |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
CFA663J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type A Cross section of connecting wires: 1...25mm2 Current rating: 63A Residual current: 0.3A Number of poles: 3+N Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Conform to the norm: EN 61008-1 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 6 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
CFC440J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type AC Cross section of connecting wires: 1...25mm2 Current rating: 40A Residual current: 0.3A Number of poles: 3+N Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 6kA Conform to the norm: EN 61008-1 |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
CFC440J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20 IP rating: IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type AC Cross section of connecting wires: 1...25mm2 Current rating: 40A Residual current: 0.3A Number of poles: 3+N Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 6kA Conform to the norm: EN 61008-1 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| CFC640J | HAGER |
Category: RCD Circuit Breakers Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20 Mounting: for DIN rail mounting Trade name: RCD Type of protection: RCD breaker Kind of circuit breaker: type AC Cross section of connecting wires: 1...25mm2 Residual current: 0.3A Number of poles: 3+N Current rating: 40A Rated voltage: 230/400V AC Max surge current: 250A Mechanical durability: 4000 cycles Short circuit breaking capacity: 10kA Conform to the norm: EN 61008-1 IP rating: IP20 |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
|
EPN510 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NO Relay variant: bistable; impulse |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
EPN510 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NO Relay variant: bistable; impulse Anzahl je Verpackung: 1 Stücke |
auf Bestellung 6 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| EPN515 | HAGER | EPN515 Installation Relays |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
EPN520 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Supply voltage: 110V DC; 230V AC Max. operating current: 16A Contacts configuration: NO x2 Relay variant: bistable; impulse |
auf Bestellung 10 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
EPN520 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Supply voltage: 110V DC; 230V AC Max. operating current: 16A Contacts configuration: NO x2 Relay variant: bistable; impulse Anzahl je Verpackung: 1 Stücke |
auf Bestellung 10 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
EPN524 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 12V DC; 24V AC Contacts configuration: NO x2 Relay variant: bistable; impulse |
auf Bestellung 8 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
EPN524 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 12V DC; 24V AC Contacts configuration: NO x2 Relay variant: bistable; impulse Anzahl je Verpackung: 1 Stücke |
auf Bestellung 8 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
EPN526 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 24V DC; 48V AC Contacts configuration: NO x2 Relay variant: bistable; impulse |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
EPN526 | HAGER |
Category: Installation Relays Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20 IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -5...40°C Max. operating current: 16A Supply voltage: 24V DC; 48V AC Contacts configuration: NO x2 Relay variant: bistable; impulse Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| EPN540 | HAGER | EPN540 Installation Relays |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ERC125 | HAGER | ERC125 Contactors -Installation Modular |
auf Bestellung 7 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ERC125S | HAGER | ERC125S Contactors -Installation Modular |
auf Bestellung 4 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
ERC216 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NO x2; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -10...50°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NO x2 Relay variant: monostable |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ERC216 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NO x2; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -10...50°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NO x2 Relay variant: monostable Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
ERC218 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NC + NO; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -10...50°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NC + NO Relay variant: monostable |
auf Bestellung 19 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ERC218 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NC + NO; for DIN rail mounting IP rating: IP20 Mounting: for DIN rail mounting Type of relay: installation Operating temperature: -10...50°C Max. operating current: 16A Supply voltage: 230V AC Contacts configuration: NC + NO Relay variant: monostable Anzahl je Verpackung: 1 Stücke |
auf Bestellung 19 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| ERC225 | HAGER | ERC225 Contactors -Installation Modular |
auf Bestellung 8 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ERC325 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C Mounting: for DIN rail mounting Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 3-pole installation Manufacturer series: ERC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERC325S | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C Mounting: for DIN rail mounting Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 3-pole installation Manufacturer series: ERC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERC418 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NC x2 + NO x2; 16A; -10÷50°C Type of relay: installation Relay variant: monostable Contacts configuration: NC x2 + NO x2 Mounting: for DIN rail mounting Max. operating current: 16A Operating temperature: -10...50°C IP rating: IP20 Supply voltage: 230V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERC425 | HAGER | ERC425 Contactors -Installation Modular |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ERC426 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 4-pole installation; 25A; 230VAC; NC x4; ERC; -10÷50°C Type of contactor: 4-pole installation Max. operating current: 25A Control voltage: 230V AC Contacts configuration: NC x4 Mounting: for DIN rail mounting Manufacturer series: ERC Leads: screw terminals Operating temperature: -10...50°C Switched voltage: max. 440V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERD216 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NO x2; for DIN rail mounting Operating temperature: -10...50°C Mounting: for DIN rail mounting IP rating: IP20 Relay variant: monostable Contacts configuration: NO x2 Type of relay: installation Max. operating current: 16A Supply voltage: 24V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERD218 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NC + NO; for DIN rail mounting Type of relay: installation Relay variant: monostable Contacts configuration: NC + NO Mounting: for DIN rail mounting Max. operating current: 16A Operating temperature: -10...50°C IP rating: IP20 Supply voltage: 24V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERD225 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 24VAC; NO x2; ERD; -10÷50°C Type of contactor: 2-pole installation Max. operating current: 25A Control voltage: 24V AC Contacts configuration: NO x2 Mounting: for DIN rail mounting Manufacturer series: ERD Leads: screw terminals Operating temperature: -10...50°C Switched voltage: max. 440V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
|
ERD225SDC | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 24VDC; NO x2; ERD; -10÷50°C Type of contactor: 2-pole installation Max. operating current: 25A Control voltage: 24V DC Contacts configuration: NO x2 Mounting: for DIN rail mounting Manufacturer series: ERD Leads: screw terminals Operating temperature: -10...50°C Switched voltage: max. 440V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | ||||||
| ERD425 | HAGER | ERD425 Contactors -Installation Modular |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ERL218 | HAGER |
Category: Installation Relays Description: Relay: installation; monostable; NC + NO; for DIN rail mounting Type of relay: installation Relay variant: monostable Contacts configuration: NC + NO Mounting: for DIN rail mounting Max. operating current: 16A Operating temperature: -10...50°C IP rating: IP20 Supply voltage: 12V AC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH | |||||||
| ERL425SDC | HAGER | ERL425SDC Contactors -Installation Modular |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
| ESC080 | HAGER | ESC080 Contactors - Accessories |
auf Bestellung 6 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
ESC225 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 2-pole installation Contacts configuration: NO x2 |
auf Bestellung 11 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ESC225 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 2-pole installation Contacts configuration: NO x2 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 11 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
ESC227 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 2-pole installation Contacts configuration: NC + NO |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ESC227 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 2-pole installation Contacts configuration: NC + NO Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
|
ESC240 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C Type of contactor: 2-pole installation Max. operating current: 40A Control voltage: 230V AC Contacts configuration: NO Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Switched voltage: max. 440V AC |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ESC240 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C Type of contactor: 2-pole installation Max. operating current: 40A Control voltage: 230V AC Contacts configuration: NO Mounting: for DIN rail mounting Manufacturer series: ESC Leads: screw terminals Operating temperature: -10...50°C Switched voltage: max. 440V AC Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| ESC263 | HAGER | ESC263 Contactors -Installation Modular |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||
|
ESC325 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C Mounting: for DIN rail mounting Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 3-pole installation Manufacturer series: ESC |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
|
ESC325 | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C Mounting: for DIN rail mounting Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 3-pole installation Manufacturer series: ESC Anzahl je Verpackung: 1 Stücke |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||
| ESC325S | HAGER |
Category: Contactors -Installation Modular Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C Mounting: for DIN rail mounting Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -10...50°C Max. operating current: 25A Control voltage: 230V AC Switched voltage: max. 440V AC Type of contactor: 3-pole installation Manufacturer series: ESC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
| CDC640J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 40A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
IP rating: IP20
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 40A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
IP rating: IP20
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| CDC663J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Current rating: 63A
Residual current: 30mA
Max surge current: 250A
Number of poles: 3+N
Rated voltage: 230/400V AC
Mounting: for DIN rail mounting
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Short circuit breaking capacity: 10kA
Mechanical durability: 4000 cycles
Conform to the norm: EN 61008-1
Trade name: RCD
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Current rating: 63A
Residual current: 30mA
Max surge current: 250A
Number of poles: 3+N
Rated voltage: 230/400V AC
Mounting: for DIN rail mounting
IP rating: IP20
Cross section of connecting wires: 1...25mm2
Short circuit breaking capacity: 10kA
Mechanical durability: 4000 cycles
Conform to the norm: EN 61008-1
Trade name: RCD
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| CDF525D |
Hersteller: HAGER
CDF525D RCD Circuit Breakers
CDF525D RCD Circuit Breakers
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 165.24 EUR |
| CDF540D |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; 240VAC
Mounting: for DIN rail mounting
IP rating: IP20
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type F
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 1+N
Current rating: 40A
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 30mA; Max surge current: 250A; 240VAC
Mounting: for DIN rail mounting
IP rating: IP20
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type F
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 1+N
Current rating: 40A
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| CDF625D |
Hersteller: HAGER
CDF625D RCD Circuit Breakers
CDF625D RCD Circuit Breakers
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 210.37 EUR |
| CDF640D |
Hersteller: HAGER
CDF640D RCD Circuit Breakers
CDF640D RCD Circuit Breakers
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 221.69 EUR |
| CDS263D |
Hersteller: HAGER
CDS263D RCD Circuit Breakers
CDS263D RCD Circuit Breakers
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 82.53 EUR |
| CDS440D |
Hersteller: HAGER
CDS440D RCD Circuit Breakers
CDS440D RCD Circuit Breakers
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 97.98 EUR |
| CDS463D |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Conform to the norm: EN 61008-1
Trade name: RCD
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 63A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Type of protection: RCD breaker
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Conform to the norm: EN 61008-1
Trade name: RCD
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 63A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Type of protection: RCD breaker
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 108.98 EUR |
| 5+ | 101.72 EUR |
| 10+ | 100.9 EUR |
| CDS463D |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Conform to the norm: EN 61008-1
Trade name: RCD
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 63A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Type of protection: RCD breaker
Anzahl je Verpackung: 1 Stücke
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 30mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Conform to the norm: EN 61008-1
Trade name: RCD
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 30mA
Number of poles: 3+N
Current rating: 63A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Type of protection: RCD breaker
Anzahl je Verpackung: 1 Stücke
auf Bestellung 11 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 108.98 EUR |
| 5+ | 101.72 EUR |
| 10+ | 100.9 EUR |
| CEA540J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20
Current rating: 40A
IP rating: IP20
Conform to the norm: EN 61008-1
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 0.1A
Number of poles: 1+N
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20
Current rating: 40A
IP rating: IP20
Conform to the norm: EN 61008-1
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 0.1A
Number of poles: 1+N
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 112.91 EUR |
| CEA540J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20
Current rating: 40A
IP rating: IP20
Conform to the norm: EN 61008-1
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 0.1A
Number of poles: 1+N
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Anzahl je Verpackung: 1 Stücke
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 100mA; Max surge current: 250A; IP20
Current rating: 40A
IP rating: IP20
Conform to the norm: EN 61008-1
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Residual current: 0.1A
Number of poles: 1+N
Rated voltage: 240V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 112.91 EUR |
| 5+ | 105.38 EUR |
| 10+ | 104.53 EUR |
| CEA640J |
Hersteller: HAGER
CEA640J RCD Circuit Breakers
CEA640J RCD Circuit Breakers
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 133.76 EUR |
| CFA440J |
Hersteller: HAGER
CFA440J RCD Circuit Breakers
CFA440J RCD Circuit Breakers
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 82.17 EUR |
| CFA563J |
Hersteller: HAGER
CFA563J RCD Circuit Breakers
CFA563J RCD Circuit Breakers
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 152.65 EUR |
| CFA663J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Current rating: 63A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Current rating: 63A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 104.68 EUR |
| 5+ | 97.7 EUR |
| CFA663J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Current rating: 63A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
Anzahl je Verpackung: 1 Stücke
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 63A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type A
Cross section of connecting wires: 1...25mm2
Current rating: 63A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
Anzahl je Verpackung: 1 Stücke
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 104.68 EUR |
| 5+ | 97.7 EUR |
| 10+ | 96.93 EUR |
| CFC440J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Current rating: 40A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Conform to the norm: EN 61008-1
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Current rating: 40A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Conform to the norm: EN 61008-1
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 90.83 EUR |
| CFC440J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Current rating: 40A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Conform to the norm: EN 61008-1
Anzahl je Verpackung: 1 Stücke
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Current rating: 40A
Residual current: 0.3A
Number of poles: 3+N
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 6kA
Conform to the norm: EN 61008-1
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 90.83 EUR |
| 5+ | 84.78 EUR |
| 10+ | 84.11 EUR |
| CFC640J |
Hersteller: HAGER
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Residual current: 0.3A
Number of poles: 3+N
Current rating: 40A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
IP rating: IP20
Category: RCD Circuit Breakers
Description: RCD breaker; Inom: 40A; Ires: 300mA; Max surge current: 250A; IP20
Mounting: for DIN rail mounting
Trade name: RCD
Type of protection: RCD breaker
Kind of circuit breaker: type AC
Cross section of connecting wires: 1...25mm2
Residual current: 0.3A
Number of poles: 3+N
Current rating: 40A
Rated voltage: 230/400V AC
Max surge current: 250A
Mechanical durability: 4000 cycles
Short circuit breaking capacity: 10kA
Conform to the norm: EN 61008-1
IP rating: IP20
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| EPN510 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO
Relay variant: bistable; impulse
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO
Relay variant: bistable; impulse
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 31.07 EUR |
| 6+ | 29.01 EUR |
| EPN510 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 31.07 EUR |
| 6+ | 29.01 EUR |
| 12+ | 28.79 EUR |
| EPN515 |
Hersteller: HAGER
EPN515 Installation Relays
EPN515 Installation Relays
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 37.39 EUR |
| EPN520 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Supply voltage: 110V DC; 230V AC
Max. operating current: 16A
Contacts configuration: NO x2
Relay variant: bistable; impulse
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Supply voltage: 110V DC; 230V AC
Max. operating current: 16A
Contacts configuration: NO x2
Relay variant: bistable; impulse
auf Bestellung 10 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 38.15 EUR |
| 5+ | 35.61 EUR |
| 10+ | 35.32 EUR |
| EPN520 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Supply voltage: 110V DC; 230V AC
Max. operating current: 16A
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Supply voltage: 110V DC; 230V AC
Max. operating current: 16A
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
auf Bestellung 10 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 38.15 EUR |
| 5+ | 35.61 EUR |
| 10+ | 35.32 EUR |
| EPN524 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 12V DC; 24V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 12V DC; 24V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
auf Bestellung 8 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 29.4 EUR |
| 5+ | 27.44 EUR |
| EPN524 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 12V DC; 24V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 12V DC; 24V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 29.4 EUR |
| 5+ | 27.44 EUR |
| 10+ | 27.23 EUR |
| EPN526 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 24V DC; 48V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 24V DC; 48V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 35.75 EUR |
| EPN526 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 24V DC; 48V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; bistable,impulse; NO x2; 16A; -5÷40°C; IP20
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -5...40°C
Max. operating current: 16A
Supply voltage: 24V DC; 48V AC
Contacts configuration: NO x2
Relay variant: bistable; impulse
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 35.75 EUR |
| 5+ | 27.61 EUR |
| 10+ | 27.4 EUR |
| EPN540 |
Hersteller: HAGER
EPN540 Installation Relays
EPN540 Installation Relays
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 71.5 EUR |
| 10+ | 70.13 EUR |
| ERC125 |
Hersteller: HAGER
ERC125 Contactors -Installation Modular
ERC125 Contactors -Installation Modular
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 40.64 EUR |
| ERC125S |
Hersteller: HAGER
ERC125S Contactors -Installation Modular
ERC125S Contactors -Installation Modular
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 52.5 EUR |
| ERC216 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO x2
Relay variant: monostable
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO x2
Relay variant: monostable
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 71.5 EUR |
| ERC216 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO x2
Relay variant: monostable
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NO x2
Relay variant: monostable
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 71.5 EUR |
| 6+ | 31.1 EUR |
| 12+ | 30.86 EUR |
| ERC218 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NC + NO
Relay variant: monostable
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NC + NO
Relay variant: monostable
auf Bestellung 19 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 32.39 EUR |
| 6+ | 30.23 EUR |
| 12+ | 30 EUR |
| ERC218 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NC + NO
Relay variant: monostable
Anzahl je Verpackung: 1 Stücke
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
IP rating: IP20
Mounting: for DIN rail mounting
Type of relay: installation
Operating temperature: -10...50°C
Max. operating current: 16A
Supply voltage: 230V AC
Contacts configuration: NC + NO
Relay variant: monostable
Anzahl je Verpackung: 1 Stücke
auf Bestellung 19 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 3+ | 32.39 EUR |
| 6+ | 30.23 EUR |
| 12+ | 30 EUR |
| ERC225 |
Hersteller: HAGER
ERC225 Contactors -Installation Modular
ERC225 Contactors -Installation Modular
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 49.81 EUR |
| ERC325 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ERC
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ERC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERC325S |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ERC
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ERC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ERC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERC418 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NC x2 + NO x2; 16A; -10÷50°C
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC x2 + NO x2
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 230V AC
Category: Installation Relays
Description: Relay: installation; monostable; NC x2 + NO x2; 16A; -10÷50°C
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC x2 + NO x2
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 230V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERC425 |
Hersteller: HAGER
ERC425 Contactors -Installation Modular
ERC425 Contactors -Installation Modular
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 76.55 EUR |
| 2+ | 66.35 EUR |
| ERC426 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 4-pole installation; 25A; 230VAC; NC x4; ERC; -10÷50°C
Type of contactor: 4-pole installation
Max. operating current: 25A
Control voltage: 230V AC
Contacts configuration: NC x4
Mounting: for DIN rail mounting
Manufacturer series: ERC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Category: Contactors -Installation Modular
Description: Contactor: 4-pole installation; 25A; 230VAC; NC x4; ERC; -10÷50°C
Type of contactor: 4-pole installation
Max. operating current: 25A
Control voltage: 230V AC
Contacts configuration: NC x4
Mounting: for DIN rail mounting
Manufacturer series: ERC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERD216 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
Operating temperature: -10...50°C
Mounting: for DIN rail mounting
IP rating: IP20
Relay variant: monostable
Contacts configuration: NO x2
Type of relay: installation
Max. operating current: 16A
Supply voltage: 24V AC
Category: Installation Relays
Description: Relay: installation; monostable; NO x2; for DIN rail mounting
Operating temperature: -10...50°C
Mounting: for DIN rail mounting
IP rating: IP20
Relay variant: monostable
Contacts configuration: NO x2
Type of relay: installation
Max. operating current: 16A
Supply voltage: 24V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERD218 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC + NO
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 24V AC
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC + NO
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 24V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERD225 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 24VAC; NO x2; ERD; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 25A
Control voltage: 24V AC
Contacts configuration: NO x2
Mounting: for DIN rail mounting
Manufacturer series: ERD
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 24VAC; NO x2; ERD; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 25A
Control voltage: 24V AC
Contacts configuration: NO x2
Mounting: for DIN rail mounting
Manufacturer series: ERD
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERD225SDC |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 24VDC; NO x2; ERD; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 25A
Control voltage: 24V DC
Contacts configuration: NO x2
Mounting: for DIN rail mounting
Manufacturer series: ERD
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 24VDC; NO x2; ERD; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 25A
Control voltage: 24V DC
Contacts configuration: NO x2
Mounting: for DIN rail mounting
Manufacturer series: ERD
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERD425 |
Hersteller: HAGER
ERD425 Contactors -Installation Modular
ERD425 Contactors -Installation Modular
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 48.73 EUR |
| ERL218 |
Hersteller: HAGER
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC + NO
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 12V AC
Category: Installation Relays
Description: Relay: installation; monostable; NC + NO; for DIN rail mounting
Type of relay: installation
Relay variant: monostable
Contacts configuration: NC + NO
Mounting: for DIN rail mounting
Max. operating current: 16A
Operating temperature: -10...50°C
IP rating: IP20
Supply voltage: 12V AC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| ERL425SDC |
Hersteller: HAGER
ERL425SDC Contactors -Installation Modular
ERL425SDC Contactors -Installation Modular
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 97.45 EUR |
| ESC080 |
Hersteller: HAGER
ESC080 Contactors - Accessories
ESC080 Contactors - Accessories
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 36.32 EUR |
| ESC225 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NO x2
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NO x2
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 43.43 EUR |
| 6+ | 40.54 EUR |
| ESC225 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NO x2
Anzahl je Verpackung: 1 Stücke
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NO x2; ESC; -10÷50°C
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NO x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 11 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 43.43 EUR |
| 6+ | 40.54 EUR |
| 12+ | 40.23 EUR |
| ESC227 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NC + NO
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NC + NO
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 71.5 EUR |
| ESC227 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NC + NO
Anzahl je Verpackung: 1 Stücke
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 25A; 230VAC; NC + NO; ESC
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 2-pole installation
Contacts configuration: NC + NO
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 71.5 EUR |
| 6+ | 49.72 EUR |
| 12+ | 49.34 EUR |
| ESC240 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 40A
Control voltage: 230V AC
Contacts configuration: NO
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 40A
Control voltage: 230V AC
Contacts configuration: NO
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 95.87 EUR |
| ESC240 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 40A
Control voltage: 230V AC
Contacts configuration: NO
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Anzahl je Verpackung: 1 Stücke
Category: Contactors -Installation Modular
Description: Contactor: 2-pole installation; 40A; 230VAC; NO; ESC; -10÷50°C
Type of contactor: 2-pole installation
Max. operating current: 40A
Control voltage: 230V AC
Contacts configuration: NO
Mounting: for DIN rail mounting
Manufacturer series: ESC
Leads: screw terminals
Operating temperature: -10...50°C
Switched voltage: max. 440V AC
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 95.87 EUR |
| 4+ | 89.49 EUR |
| 12+ | 83.1 EUR |
| ESC263 |
Hersteller: HAGER
ESC263 Contactors -Installation Modular
ESC263 Contactors -Installation Modular
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 1+ | 112.37 EUR |
| ESC325 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 59.13 EUR |
| ESC325 |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
Anzahl je Verpackung: 1 Stücke
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)| Anzahl | Preis |
|---|---|
| 2+ | 59.13 EUR |
| 6+ | 55.18 EUR |
| 12+ | 54.75 EUR |
| ESC325S |
Hersteller: HAGER
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
Category: Contactors -Installation Modular
Description: Contactor: 3-pole installation; 25A; 230VAC; NO x3; ESC; -10÷50°C
Mounting: for DIN rail mounting
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -10...50°C
Max. operating current: 25A
Control voltage: 230V AC
Switched voltage: max. 440V AC
Type of contactor: 3-pole installation
Manufacturer series: ESC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH














