| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Privatkunde |
|---|---|---|---|---|---|
|
KD7 00111161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 00111161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 00111161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161017 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161020 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161110 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100161118 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100162018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Kind of display used: LCD TFT 5,7" Display resolution: 320x240 Interface: RS485; USB Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs Standard equipment: CF 4GB memory card Supply voltage: 18...30V DC DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English; vertical Pollution degree: 2 Temperature measuring range: -200...1760°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100162028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Kind of display used: LCD TFT 5,7" Display resolution: 320x240 Interface: RS485; USB Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs Standard equipment: CF 4GB memory card Supply voltage: 18...30V DC DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English; vertical Pollution degree: 2 Temperature measuring range: -200...1760°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100162128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100261010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100261018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English; vertical Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262020 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262110 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262118 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 18...30V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100262128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100361010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS232; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10100361018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Operating temperature: 0...55°C Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS232; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161020 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161021 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161027 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161110 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161111 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161118 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161120 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161121 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110161128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10110262128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10150162128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10151161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10151161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10151161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 10177261125 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; without an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11100162028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Kind of display used: LCD TFT 5,7" Display resolution: 320x240 Interface: RS485; USB Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs Standard equipment: CF 4GB memory card Supply voltage: 18...30V DC DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Temperature measuring range: -200...1760°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11100262128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); with an extra quality inspection certificate DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161020 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161021 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161027 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110161028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Operating temperature: 0...55°C Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11110262128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos) Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11111161010 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11111161011 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11111161018 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos) DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11150262128 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Supply voltage: 18...30V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs Manufacturer series: KD7 DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11150361028 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: English Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS232; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
|
KD7 11150361121 | LUMEL |
Category: Digital Panel Meters - OthersDescription: Data logger; DC voltage,DC current,resistance,temperature Manufacturer series: KD7 Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T IP rating: IP20 at terminal side; IP65 (from the front) Measurement: DC current; DC voltage; resistance; temperature Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C) Storage temperature: -20...60°C Supply voltage: 90...253V AC; 90...300V DC Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs DC voltage measuring accuracy: ±0.15% Max. environment humidity: 70% Standard equipment: CF 4GB memory card; with an extra quality inspection certificate Operating system: Windows CE Kind of meter: digital; programmable Touchpad: yes DC current measuring accuracy: ±0.15% Operating temperature: 0...55°C Version: polska Pollution degree: 2 Kind of display used: LCD TFT 5,7" Temperature measuring range: -200...1760°C DC current measuring range: 0...20mA DC voltage measuring range: 0...9999mV Display resolution: 320x240 Bargraph: yes Dimensions: 144x144mm Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP Power consumption: 30VA Interface: Ethernet; RS232; RS485; USB Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1 Type of meter: data logger Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
| KD7 00111161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 00111161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 00111161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161017 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161020 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161110 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100161118 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100162018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Temperature measuring range: -200...1760°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Temperature measuring range: -200...1760°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100162028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Temperature measuring range: -200...1760°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Temperature measuring range: -200...1760°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100162128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100261010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100261018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English; vertical
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262020 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262110 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262118 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 18...30V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100262128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100361010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10100361018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Operating temperature: 0...55°C
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161020 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161021 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161027 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161110 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161111 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161118 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161120 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161121 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110161128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10110262128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10150162128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10151161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10151161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10151161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 10177261125 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; without an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs; slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; without an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11100162028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Temperature measuring range: -200...1760°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Kind of display used: LCD TFT 5,7"
Display resolution: 320x240
Interface: RS485; USB
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs
Standard equipment: CF 4GB memory card
Supply voltage: 18...30V DC
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Temperature measuring range: -200...1760°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11100262128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); with an extra quality inspection certificate
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); with an extra quality inspection certificate
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161020 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161021 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161027 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110161028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Operating temperature: 0...55°C
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11110262128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos)
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11111161010 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11111161011 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11111161018 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 alarms (NO relays) + 8 alarms (OptoMos); slot4 - 8 alarms (NO relays) + 8 alarms (OptoMos)
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11150262128 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Supply voltage: 18...30V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
Manufacturer series: KD7
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11150361028 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: English
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH
| KD7 11150361121 |
![]() |
Hersteller: LUMEL
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Category: Digital Panel Meters - Others
Description: Data logger; DC voltage,DC current,resistance,temperature
Manufacturer series: KD7
Kind of temperature sensor: Cu100; Ni100; Pt100; Pt500; Pt1000; thermocouple B; thermocouple E; thermocouple J; thermocouple K; thermocouple L; thermocouple N; thermocouple R; thermocouple T
IP rating: IP20 at terminal side; IP65 (from the front)
Measurement: DC current; DC voltage; resistance; temperature
Input: E-type thermocouple (-200...1000°C); J-type thermocouple (-200...1200°C); K-type thermocouple (-200...1372°C); N-type thermocouple (-100...1300°C); Pt 100 (-200...850°C); Pt 500 (-200...850°C); Pt 1000 (-200...850°C); R-type thermocouple (0...1760°C); S-type thermocouple (0...1760°C); T-type thermocouple (-200...400°C)
Storage temperature: -20...60°C
Supply voltage: 90...253V AC; 90...300V DC
Measuring instrument features: 24 measuring ranges; advanced math functions; measurements are shown in the form of graph on PC screen; slot1 - 6 programmable measurement inputs; slot2 - 6 programmable measurement inputs; slot3 - 8 digital inputs + 4 analog outputs
DC voltage measuring accuracy: ±0.15%
Max. environment humidity: 70%
Standard equipment: CF 4GB memory card; with an extra quality inspection certificate
Operating system: Windows CE
Kind of meter: digital; programmable
Touchpad: yes
DC current measuring accuracy: ±0.15%
Operating temperature: 0...55°C
Version: polska
Pollution degree: 2
Kind of display used: LCD TFT 5,7"
Temperature measuring range: -200...1760°C
DC current measuring range: 0...20mA
DC voltage measuring range: 0...9999mV
Display resolution: 320x240
Bargraph: yes
Dimensions: 144x144mm
Communictions protocol: FTP; Modbus master; Modbus slave; Modbus TCP/IP
Power consumption: 30VA
Interface: Ethernet; RS232; RS485; USB
Conform to the norm: EN 61000-6-2; EN 61000-6-4; EN 61010-1
Type of meter: data logger
Software: KD7 SETUP; KD ARCHIVE; KD CHECK; KD CONNECT
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH