Produkte > MEGGER > 1004-739
1004-739

1004-739 MEGGER


Hersteller: MEGGER
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; R range: 0.01÷1000kΩ; 1nF÷10uF
Type of meter: insulation resistance
IP rating: IP54
Kind of display used: LCD
Bargraph: yes
DC voltage measuring range: 0...600V
Resistance measuring range: 10Ω...1MΩ
AC voltage measuring range: 10mV...600V
Capacitance measuring range: 1nF...10µF
Body dimensions: 228x108x63mm
Resistance measuring accuracy: ±(5%+2 digit)
Frequency measuring accuracy: ±(0.5%+1 digit)
Capacitance measuring accuracy: ±(5%+ 2 digit)
AC voltage measuring accuracy: ±(2% + 1 digit)
DC voltage measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 2digit)
Test voltage: 10...1000V; 50V; 100V; 250V; 500V; 1kV
Frequency measuring range: 15...400Hz
Bandwidth for AC voltage measurements: 15...400Hz
Weight with battery: 1.75kg
Insulation resistance measuring ranges: 10GΩ; 20GΩ; 50GΩ; 100GΩ; 200GΩ
Standard equipment: manufacturer's calibration certificate; soft case; test leads; test probe x1
Input impedance: 0.25MΩ
Measuring instrument features: automatic power-off; polarization index (PI) and dielelectric absorption ratio (DAR); time testing
Continuity test: 10mΩ...99.9Ω
Measurement: AC voltage; capacitance; continuity; DC voltage; frequency; insulation resistance; resistance
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:

Lieferzeit 7-14 Tag (e)
Anzahl Preis
1+1014.16 EUR
Im Einkaufswagen  Stück im Wert von  UAH
Produktrezensionen
Produktbewertung abgeben

Technische Details 1004-739 MEGGER

Category: Insulation Resistance Meters, Description: Meter: insulation resistance; LCD; R range: 0.01÷1000kΩ; 1nF÷10uF, Type of meter: insulation resistance, IP rating: IP54, Kind of display used: LCD, Bargraph: yes, DC voltage measuring range: 0...600V, Resistance measuring range: 10Ω...1MΩ, AC voltage measuring range: 10mV...600V, Capacitance measuring range: 1nF...10µF, Body dimensions: 228x108x63mm, Resistance measuring accuracy: ±(5%+2 digit), Frequency measuring accuracy: ±(0.5%+1 digit), Capacitance measuring accuracy: ±(5%+ 2 digit), AC voltage measuring accuracy: ±(2% + 1 digit), DC voltage measuring accuracy: ±(2% + 2 digit), Insulation resistance measuring accuracy: ±(2% + 2digit), Test voltage: 10...1000V; 50V; 100V; 250V; 500V; 1kV, Frequency measuring range: 15...400Hz, Bandwidth for AC voltage measurements: 15...400Hz, Weight with battery: 1.75kg, Insulation resistance measuring ranges: 10GΩ; 20GΩ; 50GΩ; 100GΩ; 200GΩ, Standard equipment: manufacturer's calibration certificate; soft case; test leads; test probe x1, Input impedance: 0.25MΩ, Measuring instrument features: automatic power-off; polarization index (PI) and dielelectric absorption ratio (DAR); time testing, Continuity test: 10mΩ...99.9Ω, Measurement: AC voltage; capacitance; continuity; DC voltage; frequency; insulation resistance; resistance, Power supply: battery LR6 AA 1,5V x6, Battery/ rechargeable battery: battery LR6 AA 1,5V x6, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote 1004-739 nach Preis ab 1014.16 EUR bis 1014.16 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis
1004-739 1004-739 Hersteller : MEGGER Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; R range: 0.01÷1000kΩ; 1nF÷10uF
Type of meter: insulation resistance
IP rating: IP54
Kind of display used: LCD
Bargraph: yes
DC voltage measuring range: 0...600V
Resistance measuring range: 10Ω...1MΩ
AC voltage measuring range: 10mV...600V
Capacitance measuring range: 1nF...10µF
Body dimensions: 228x108x63mm
Resistance measuring accuracy: ±(5%+2 digit)
Frequency measuring accuracy: ±(0.5%+1 digit)
Capacitance measuring accuracy: ±(5%+ 2 digit)
AC voltage measuring accuracy: ±(2% + 1 digit)
DC voltage measuring accuracy: ±(2% + 2 digit)
Insulation resistance measuring accuracy: ±(2% + 2digit)
Test voltage: 10...1000V; 50V; 100V; 250V; 500V; 1kV
Frequency measuring range: 15...400Hz
Bandwidth for AC voltage measurements: 15...400Hz
Weight with battery: 1.75kg
Insulation resistance measuring ranges: 10GΩ; 20GΩ; 50GΩ; 100GΩ; 200GΩ
Standard equipment: manufacturer's calibration certificate; soft case; test leads; test probe x1
Input impedance: 0.25MΩ
Measuring instrument features: automatic power-off; polarization index (PI) and dielelectric absorption ratio (DAR); time testing
Continuity test: 10mΩ...99.9Ω
Measurement: AC voltage; capacitance; continuity; DC voltage; frequency; insulation resistance; resistance
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis
1+1014.16 EUR
Im Einkaufswagen  Stück im Wert von  UAH
10-04739 10-04739 Hersteller : Tensility International Corp 10-04739.pdf?X-Amz-Expires=600&X-Amz-Date=20230121T170148Z&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIAIS2S4WRDQDSWDRZQ%2F20230121%2Fus-west-2%2Fs3%2Faws4_request&X-Amz-SignedHeaders=host&X-Amz Description: CABLE MALE TO WIRE LEAD 5P 32.8'
Produkt ist nicht verfügbar
Im Einkaufswagen  Stück im Wert von  UAH