16024-9892 BREVE TUFVASSONS
Hersteller: BREVE TUFVASSONSCategory: PCB transformers
Description: Transformer: encapsulated; 25VA; 400VAC; 24V; 1041.6mA; PCB; IP00
Secondary winding terminals: 9-13
Manufacturer series: TEZ
Conform to the norm: PN EN 61558-1:2000; PN EN 61558-2-1:2000; PN EN 61558-2-6:2000
Type of transformer: encapsulated
Mounting: PCB
IP rating: IP00
Thermal class: Ta40B
A2 dimension: 30mm
A1 dimension: 32.5mm
C dimension: 51.5mm
A dimension: 53.8mm
B dimension: 63.6mm
Secondary winding current 1: 1041.6mA
Secondary voltage 1: 24V
Power: 25VA
Primary voltage: 400V AC
Electrical insulation strength: 4kV/60s
Primary winding terminals: 1-7
Anzahl je Verpackung: 1 Stücke
auf Bestellung 20 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 4+ | 19.51 EUR |
| 5+ | 18.12 EUR |
| 20+ | 16.95 EUR |
| 100+ | 15.77 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details 16024-9892 BREVE TUFVASSONS
Category: PCB transformers, Description: Transformer: encapsulated; 25VA; 400VAC; 24V; 1041.6mA; PCB; IP00, Secondary winding terminals: 9-13, Manufacturer series: TEZ, Conform to the norm: PN EN 61558-1:2000; PN EN 61558-2-1:2000; PN EN 61558-2-6:2000, Type of transformer: encapsulated, Mounting: PCB, IP rating: IP00, Thermal class: Ta40B, A2 dimension: 30mm, A1 dimension: 32.5mm, C dimension: 51.5mm, A dimension: 53.8mm, B dimension: 63.6mm, Secondary winding current 1: 1041.6mA, Secondary voltage 1: 24V, Power: 25VA, Primary voltage: 400V AC, Electrical insulation strength: 4kV/60s, Primary winding terminals: 1-7, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote 16024-9892 nach Preis ab 16.95 EUR bis 19.51 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
16024-9892 | Hersteller : BREVE TUFVASSONS |
Category: PCB transformersDescription: Transformer: encapsulated; 25VA; 400VAC; 24V; 1041.6mA; PCB; IP00 Secondary winding terminals: 9-13 Manufacturer series: TEZ Conform to the norm: PN EN 61558-1:2000; PN EN 61558-2-1:2000; PN EN 61558-2-6:2000 Type of transformer: encapsulated Mounting: PCB IP rating: IP00 Thermal class: Ta40B A2 dimension: 30mm A1 dimension: 32.5mm C dimension: 51.5mm A dimension: 53.8mm B dimension: 63.6mm Secondary winding current 1: 1041.6mA Secondary voltage 1: 24V Power: 25VA Primary voltage: 400V AC Electrical insulation strength: 4kV/60s Primary winding terminals: 1-7 |
auf Bestellung 20 Stücke: Lieferzeit 14-21 Tag (e) |
|