C.A 6133 LAUNCH KIT CHAUVIN ARNOUX
                                                                                Hersteller: CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Continuity test: <10Ω
Interface: Bluetooth
Type of meter: appliance meter
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Power supply: rechargeable battery Ni-MH AA x6
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Software: dedicated mobile app
IP rating: IP54
Kind of display used: LCD
Illumination: yes
Bargraph: yes
AC voltage measuring range: 2...550V
Resistance measuring range: 1...10Ω; 100kΩ
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
Frequency measuring range: 30...1000Hz
Dimensions: 223x126x70mm
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
AC voltage measuring accuracy: ±(1% + 2 digit)
Measurement memory: 2970
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Anzahl je Verpackung: 1 Stücke
            
                    Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth
RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose
Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
Continuity test: <10Ω
Interface: Bluetooth
Type of meter: appliance meter
Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function
Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6
Power supply: rechargeable battery Ni-MH AA x6
Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1
Software: dedicated mobile app
IP rating: IP54
Kind of display used: LCD
Illumination: yes
Bargraph: yes
AC voltage measuring range: 2...550V
Resistance measuring range: 1...10Ω; 100kΩ
Insulation resistance measuring ranges: 0...100MΩ; 1GΩ
Frequency measuring accuracy: ±(0.1%+1 digit)
Frequency measuring range: 30...1000Hz
Dimensions: 223x126x70mm
Loop impedance measuring range: 100mΩ...1Ω; 400Ω
Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ
AC voltage measuring accuracy: ±(1% + 2 digit)
Measurement memory: 2970
Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis | 
|---|---|
| 1+ | 1279.85 EUR | 
Produktrezensionen
Produktbewertung abgeben
Technische Details C.A 6133 LAUNCH KIT CHAUVIN ARNOUX
Category: Multimeters for Electrical Installations, Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth, RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose, Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance, Continuity test: . 
Weitere Produktangebote C.A 6133 LAUNCH KIT nach Preis ab 1279.85 EUR bis 1279.85 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | 
            Verfügbarkeit             | 
        Preis | ||||
|---|---|---|---|---|---|---|---|---|---|
            ![]() +2          | 
        C.A 6133 LAUNCH KIT | Hersteller : CHAUVIN ARNOUX | 
                                    Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; VAC: 2÷550V; 30÷1000Hz; Bluetooth RCD test: 30mA, 100mA, 300mA, 500mA, 650mA; AC, A-type RCDs; general purpose Measurement: AC current (with current clamps); AC voltage; continuity; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance Continuity test: <10Ω Interface: Bluetooth Type of meter: appliance meter Measuring instrument features: automatic generation of PDF file with recorded data; magnetized case; Pass/Fail function Battery/ rechargeable battery: rechargeable battery Ni-MH AA x6 Power supply: rechargeable battery Ni-MH AA x6 Conform to the norm: CAT III 600V; EN 61010; EN 61010-2-034; IEC 61010-1; IEC 61010-2-030; IEC 61326-1 Software: dedicated mobile app IP rating: IP54 Kind of display used: LCD Illumination: yes Bargraph: yes AC voltage measuring range: 2...550V Resistance measuring range: 1...10Ω; 100kΩ Insulation resistance measuring ranges: 0...100MΩ; 1GΩ Frequency measuring accuracy: ±(0.1%+1 digit) Frequency measuring range: 30...1000Hz Dimensions: 223x126x70mm Loop impedance measuring range: 100mΩ...1Ω; 400Ω Earthing resistance measuring range: 500mΩ...100Ω; 1kΩ; 2kΩ AC voltage measuring accuracy: ±(1% + 2 digit) Measurement memory: 2970 Standard equipment: 3 crocodile clips; battery charger/power supply; carrying case; continuity rod; kit for earth ground resistance measurement 15m; manual (CD); neckstrap; test lead; test leads ( 3pcs.); test probe x1; USB cable  | 
        
                             auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) | 
        
            
  | 
    