Description: Meter: network parameters; on panel; digital,mounting; LCD
Mounting: on panel
IP rating: IP20 at terminal side; IP54 (from the front)
Mounting hole diameter: 92x92mm
AC current measuring accuracy: ±0,5%
Communictions protocol: Modbus ASCII; Modbus RTU
Interface: optical port; RS485
Dimensions (W x H x D): 96x96x73.5mm
Type of meter: network parameters
AC voltage measuring accuracy: ±0,5%
Measurement: active power; AC voltage; apparent power; energy; frequency; power factor; reactive power
AC current measuring range: 315...6.3kA
Diameter: 240mm
Maximum current: 6300A
Supply voltage: 100...440V AC; 120...250V DC
Measuring instrument features: multilanguage menu
Standard equipment: Rogowski coil
Cable length: 2m
Kind of network: three-phase
Kind of meter: digital; mounting
Kind of display used: LCD
Active power measuring accuracy: ±1%
True effective value measurement: True RMS
Kind of measurement: with a rogowski coil
Frequency measuring range: 45...65Hz
AC voltage measuring range: 50...415V
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar

Produktrezensionen
Produktbewertung abgeben

Technische Details DMG611R6300 LOVATO ELECTRIC

Category: Power Network Meters and Analyzers, Description: Meter: network parameters; on panel; digital,mounting; LCD, Mounting: on panel, IP rating: IP20 at terminal side; IP54 (from the front), Mounting hole diameter: 92x92mm, AC current measuring accuracy: ±0,5%, Communictions protocol: Modbus ASCII; Modbus RTU, Interface: optical port; RS485, Dimensions (W x H x D): 96x96x73.5mm, Type of meter: network parameters, AC voltage measuring accuracy: ±0,5%, Measurement: active power; AC voltage; apparent power; energy; frequency; power factor; reactive power, AC current measuring range: 315...6.3kA, Diameter: 240mm, Maximum current: 6300A, Supply voltage: 100...440V AC; 120...250V DC, Measuring instrument features: multilanguage menu, Standard equipment: Rogowski coil, Cable length: 2m, Kind of network: three-phase, Kind of meter: digital; mounting, Kind of display used: LCD, Active power measuring accuracy: ±1%, True effective value measurement: True RMS, Kind of measurement: with a rogowski coil, Frequency measuring range: 45...65Hz, AC voltage measuring range: 50...415V, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote DMG611R6300

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
DMG611R6300 Hersteller : LOVATO ELECTRIC DMG611_IT_EN.pdf Category: Power Network Meters and Analyzers
Description: Meter: network parameters; on panel; digital,mounting; LCD
Mounting: on panel
IP rating: IP20 at terminal side; IP54 (from the front)
Mounting hole diameter: 92x92mm
AC current measuring accuracy: ±0,5%
Communictions protocol: Modbus ASCII; Modbus RTU
Interface: optical port; RS485
Dimensions (W x H x D): 96x96x73.5mm
Type of meter: network parameters
AC voltage measuring accuracy: ±0,5%
Measurement: active power; AC voltage; apparent power; energy; frequency; power factor; reactive power
AC current measuring range: 315...6.3kA
Diameter: 240mm
Maximum current: 6300A
Supply voltage: 100...440V AC; 120...250V DC
Measuring instrument features: multilanguage menu
Standard equipment: Rogowski coil
Cable length: 2m
Kind of network: three-phase
Kind of meter: digital; mounting
Kind of display used: LCD
Active power measuring accuracy: ±1%
True effective value measurement: True RMS
Kind of measurement: with a rogowski coil
Frequency measuring range: 45...65Hz
AC voltage measuring range: 50...415V