F405
  • F405
  • F405
  • F405
  • F405
  • F405
  • F405

F405 CHAUVIN ARNOUX


pVersion=0046&contRep=ZT&docId=005056AB752F1ED7AEE2C2A3869DAA14&compId=CA-F203_DS.PDF?ci_sign=a83b7a37bd68a9d05f81de92569596d288cf5f68 pVersion=0046&contRep=ZT&docId=005056AB752F1EE890F46DB0892E53D3&compId=CA-F405-M.PDF?ci_sign=8c62092dee948fa4467dbb5284826c121e9b0ab0 Hersteller: CHAUVIN ARNOUX
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 48mm; LCD
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function
Power supply: battery LR6 AA 1,5V x4
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Standard equipment: case; crocodile clip x1; test leads; test probes
Conform to the norm: CAT III 1000V; CAT IV 1000V; EN 61010; EN 61243-3:2010
Kind of meter: digital; pincers type
Test: diodes
Kind of display used: LCD
Type of meter: multifunction
True effective value measurement: True RMS
Illumination: yes
Max. diameter of measured cable: 48mm
Dimensions: 92x272x41mm
AC current measuring range: 150mA...1kA
DC voltage measuring range: 150mV...1kV
AC voltage measuring range: 150mV...1kV
DC current measuring range: 150mA...1.5kA
Frequency measuring accuracy: ±(0.4%+1 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Reactive power measurement: 1VAR...1MVAR
Resistance measuring range: 0.1...99.99kΩ
Apparent power measurement: 1...1000kVA
Display parameters: (10000)
Frequency measuring range: 5...20kHz
Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Continuity test: acoustic indication; 1Ω...999Ω
Produkt ist nicht verfügbar

Im Einkaufswagen  Stück im Wert von  UAH
Produktrezensionen
Produktbewertung abgeben

Technische Details F405 CHAUVIN ARNOUX

Category: Meters and AC/DC Clamp Probes, Description: Meter: multifunction; digital,pincers type; Øcable: 48mm; LCD, Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function, Power supply: battery LR6 AA 1,5V x4, Battery/ rechargeable battery: battery LR6 AA 1,5V x4, Standard equipment: case; crocodile clip x1; test leads; test probes, Conform to the norm: CAT III 1000V; CAT IV 1000V; EN 61010; EN 61243-3:2010, Kind of meter: digital; pincers type, Test: diodes, Kind of display used: LCD, Type of meter: multifunction, True effective value measurement: True RMS, Illumination: yes, Max. diameter of measured cable: 48mm, Dimensions: 92x272x41mm, AC current measuring range: 150mA...1kA, DC voltage measuring range: 150mV...1kV, AC voltage measuring range: 150mV...1kV, DC current measuring range: 150mA...1.5kA, Frequency measuring accuracy: ±(0.4%+1 digit), AC voltage measuring accuracy: ±(1% + 3 digit), AC current measuring accuracy: ±(1% + 3 digit), DC voltage measuring accuracy: ±(1% + 3 digit), DC current measuring accuracy: ±(1% + 3 digit), Resistance measuring accuracy: ±(1%+5 digit), Reactive power measurement: 1VAR...1MVAR, Resistance measuring range: 0.1...99.99kΩ, Apparent power measurement: 1...1000kVA, Display parameters: (10000), Frequency measuring range: 5...20kHz, Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance, Continuity test: acoustic indication; 1Ω...999Ω.