FLUKE 287
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
IP rating: IP54
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Display parameters: (50000)
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Kind of display used: colour; LCD TFT 2,2"
Power supply: battery LR6 AA 1,5V x6
Measurement memory: 10k
Display resolution: 320x240
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
IP rating: IP54
Manufacturer series: FLUKE 280
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Display parameters: (50000)
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Kind of display used: colour; LCD TFT 2,2"
Power supply: battery LR6 AA 1,5V x6
Measurement memory: 10k
Display resolution: 320x240
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis ohne MwSt |
---|---|
1+ | 1147.47 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE 287 FLUKE
Category: Portable digital multimeters, Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54, IP rating: IP54, Manufacturer series: FLUKE 280, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341, Type of meter: digital multimeter, Weight with battery: 871g, Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set, Continuity test: acoustic indication, Duty cycle factor: 1...99%, Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%, Pollution degree: 2, Temperature measurement resolution: 0.1°C, Conductance measurement: 10000000...50nS, Temperature measuring range: -200...1350°C, True effective value measurement: True RMS AC; True RMS AC+DC, Bargraph: 51 segm., Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature, Dimensions (W x H x D): 102x222x60mm, AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A .
Weitere Produktangebote FLUKE 287 nach Preis ab 1147.47 EUR bis 1463.96 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
+5 |
FLUKE 287 | Hersteller : FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54 IP rating: IP54 Manufacturer series: FLUKE 280 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Type of meter: digital multimeter Weight with battery: 871g Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Continuity test: acoustic indication Duty cycle factor: 1...99% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 10000000...50nS Temperature measuring range: -200...1350°C True effective value measurement: True RMS AC; True RMS AC+DC Bargraph: 51 segm. Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Dimensions (W x H x D): 102x222x60mm AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF Diode test: 1mA @3.1V Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Fluke Connect (FLK-IR3000FC) Display parameters: (50000) Frequency measuring accuracy: ±(0.005%+5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) AC current measuring accuracy: ±(0.6% + 5 digit) DC voltage measuring accuracy: ±(0.025% + 2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.05%+2 digit) Temperature measurement accuracy: ±(1% + 1°C) Kind of display used: colour; LCD TFT 2,2" Power supply: battery LR6 AA 1,5V x6 Measurement memory: 10k Display resolution: 320x240 Standard equipment: holder for probes; test leads FLK-TL71 Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||
FLUKE-287 | Hersteller : Fluke Electronics |
Description: DMM TRUE RMS 50000CNT W/BCKLGHT Packaging: Box Features: Auto Off, Backlight, Data Logging (Internal Memory), Hold, Min/Max Display Type: LCD, Bar Graph Style: Handheld Function: Voltage, Current, Resistance, Capacitance, Temperature, Frequency Type: Digital (DMM) Ranging: Auto Display Count: 50000 Functions, Extra: Continuity, dB, Diode Test Response: True RMS Part Status: Active Display Digits: 4.5 |
auf Bestellung 35 Stücke: Lieferzeit 10-14 Tag (e) |
|
|||||||
FLUKE-287 | Hersteller : Fluke | 100 kHz AC Bandwidth Multimeters |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||||
FLUKE-287 | Hersteller : Fluke | Digital Multimeters TRUE-RMS ELECTRONIC LOGGING MULTIMETER WITH TRENDCAPTURE |
Produkt ist nicht verfügbar |