FLUKE-83-5/EUR
Hersteller: FLUKECategory: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Continuity test: acoustic indication
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads
Power supply: battery 6F22 9V x1
Battery/ rechargeable battery: battery 6F22 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Type of meter: digital multimeter
IP rating: IP30
Kind of display used: LCD
True effective value measurement: True RMS AC
Illumination: yes
Bargraph: 33 segm. 40x/s
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Conductance measurement: 0.01...60S
Diode test: 1mA @3V
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.4%+1 digit)
Dimensions (W x H x D): 95x200x48mm
DC current measuring accuracy: ±(0.4% + 2 digit)
AC voltage measuring accuracy: ±(0.7% + 4 digit)
AC current measuring accuracy: ±(1.2% + 2 digit)
Capacitance measuring accuracy: ±(1%+ 2 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 600g
Display parameters: (6000)
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 1+ | 725.12 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE-83-5/EUR FLUKE
Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S, Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA, Continuity test: acoustic indication, Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads, Power supply: battery 6F22 9V x1, Battery/ rechargeable battery: battery 6F22 9V x1, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Type of meter: digital multimeter, IP rating: IP30, Kind of display used: LCD, True effective value measurement: True RMS AC, Illumination: yes, Bargraph: 33 segm. 40x/s, Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF, DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s, AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A .
Weitere Produktangebote FLUKE-83-5/EUR nach Preis ab 725.12 EUR bis 725.12 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
|---|---|---|---|---|---|---|---|---|---|
![]() +5 |
FLUKE-83-5/EUR | Hersteller : FLUKE |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; 0.01÷60S Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Continuity test: acoustic indication Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads Power supply: battery 6F22 9V x1 Battery/ rechargeable battery: battery 6F22 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Type of meter: digital multimeter IP rating: IP30 Kind of display used: LCD True effective value measurement: True RMS AC Illumination: yes Bargraph: 33 segm. 40x/s Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Conductance measurement: 0.01...60S Diode test: 1mA @3V Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.4%+1 digit) Dimensions (W x H x D): 95x200x48mm DC current measuring accuracy: ±(0.4% + 2 digit) AC voltage measuring accuracy: ±(0.7% + 4 digit) AC current measuring accuracy: ±(1.2% + 2 digit) Capacitance measuring accuracy: ±(1%+ 2 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 600g Display parameters: (6000) Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; test leads resistance compensation Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|