HDS2202 OWON
Hersteller: OWON
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 8bit; LCD 3,5"; Ch: 2; 1Gsps; 8kpts
Kind of display used: LCD 3,5"
Power supply: rechargeable battery Li-Ion 18650 3,7V 2600mAh x2
Number of channels: 2
Input impedance: 1MΩ/16pF
Dimensions: 198x96x38mm
Standard equipment: adjusting tool; case; oscilloscope probe; power supply; test lead (BNC - crocodile clips) x2; test leads ( 2pcs.); USB cable
Additional functions: multimeter
Sampling: 1Gsps
Type of oscilloscope: handheld oscilloscope
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Manufacturer series: HDS200
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; resistance
Band: 200MHz
Rise time: ≤1.75ns
AC current measuring range: 200mA; 10A
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ; 100MΩ
DC current measuring range: 200mA; 10A
DC voltage measuring range: 200mV; 2V; 20V; 200V; 1kV
AC voltage measuring range: 200mV; 2V; 20V; 200V; 750V
Capacitance measuring range: 20nF; 200nF; 2µF; 20µF; 200µF; 2mF
Memory record length: 8kpts
Capacitance measuring accuracy: ±(3%+ 10 digit)
AC current measuring accuracy: ±(1% + 10 digit)
DC voltage measuring accuracy: ±(0.3% + 5 digit); ±(0.3% + 10 digit) @200mV
DC current measuring accuracy: ±(0.8% + 10 digit)
AC voltage measuring accuracy: ±(0.8% + 10 digit); ±(1% + 10 digit) @750V
Resistance measuring accuracy: ±(0.8%+3 digit)
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Handheld oscilloscope; 200MHz; 8bit; LCD 3,5"; Ch: 2; 1Gsps; 8kpts
Kind of display used: LCD 3,5"
Power supply: rechargeable battery Li-Ion 18650 3,7V 2600mAh x2
Number of channels: 2
Input impedance: 1MΩ/16pF
Dimensions: 198x96x38mm
Standard equipment: adjusting tool; case; oscilloscope probe; power supply; test lead (BNC - crocodile clips) x2; test leads ( 2pcs.); USB cable
Additional functions: multimeter
Sampling: 1Gsps
Type of oscilloscope: handheld oscilloscope
Input coupling: AC, DC, GND
Vertical resolution: 8bit
Trigger modes: automatic; normal; single
Manufacturer series: HDS200
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; resistance
Band: 200MHz
Rise time: ≤1.75ns
AC current measuring range: 200mA; 10A
Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ; 100MΩ
DC current measuring range: 200mA; 10A
DC voltage measuring range: 200mV; 2V; 20V; 200V; 1kV
AC voltage measuring range: 200mV; 2V; 20V; 200V; 750V
Capacitance measuring range: 20nF; 200nF; 2µF; 20µF; 200µF; 2mF
Memory record length: 8kpts
Capacitance measuring accuracy: ±(3%+ 10 digit)
AC current measuring accuracy: ±(1% + 10 digit)
DC voltage measuring accuracy: ±(0.3% + 5 digit); ±(0.3% + 10 digit) @200mV
DC current measuring accuracy: ±(0.8% + 10 digit)
AC voltage measuring accuracy: ±(0.8% + 10 digit); ±(1% + 10 digit) @750V
Resistance measuring accuracy: ±(0.8%+3 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis |
---|---|
1+ | 329.03 EUR |
3+ | 311.54 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details HDS2202 OWON
Category: Portable Oscilloscopes, Scopemeters, Description: Handheld oscilloscope; 200MHz; 8bit; LCD 3,5"; Ch: 2; 1Gsps; 8kpts, Kind of display used: LCD 3,5", Power supply: rechargeable battery Li-Ion 18650 3,7V 2600mAh x2, Number of channels: 2, Input impedance: 1MΩ/16pF, Dimensions: 198x96x38mm, Standard equipment: adjusting tool; case; oscilloscope probe; power supply; test lead (BNC - crocodile clips) x2; test leads ( 2pcs.); USB cable, Additional functions: multimeter, Sampling: 1Gsps, Type of oscilloscope: handheld oscilloscope, Input coupling: AC, DC, GND, Vertical resolution: 8bit, Trigger modes: automatic; normal; single, Manufacturer series: HDS200, Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; resistance, Band: 200MHz, Rise time: ≤1.75ns, AC current measuring range: 200mA; 10A, Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ; 100MΩ, DC current measuring range: 200mA; 10A, DC voltage measuring range: 200mV; 2V; 20V; 200V; 1kV, AC voltage measuring range: 200mV; 2V; 20V; 200V; 750V, Capacitance measuring range: 20nF; 200nF; 2µF; 20µF; 200µF; 2mF, Memory record length: 8kpts, Capacitance measuring accuracy: ±(3%+ 10 digit), AC current measuring accuracy: ±(1% + 10 digit), DC voltage measuring accuracy: ±(0.3% + 5 digit); ±(0.3% + 10 digit) @200mV, DC current measuring accuracy: ±(0.8% + 10 digit), AC voltage measuring accuracy: ±(0.8% + 10 digit); ±(1% + 10 digit) @750V, Resistance measuring accuracy: ±(0.8%+3 digit), Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote HDS2202 nach Preis ab 311.54 EUR bis 329.03 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
![]() +3 |
HDS2202 | Hersteller : OWON |
Category: Portable Oscilloscopes, Scopemeters Description: Handheld oscilloscope; 200MHz; 8bit; LCD 3,5"; Ch: 2; 1Gsps; 8kpts Kind of display used: LCD 3,5" Power supply: rechargeable battery Li-Ion 18650 3,7V 2600mAh x2 Number of channels: 2 Input impedance: 1MΩ/16pF Dimensions: 198x96x38mm Standard equipment: adjusting tool; case; oscilloscope probe; power supply; test lead (BNC - crocodile clips) x2; test leads ( 2pcs.); USB cable Additional functions: multimeter Sampling: 1Gsps Type of oscilloscope: handheld oscilloscope Input coupling: AC, DC, GND Vertical resolution: 8bit Trigger modes: automatic; normal; single Manufacturer series: HDS200 Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; resistance Band: 200MHz Rise time: ≤1.75ns AC current measuring range: 200mA; 10A Resistance measuring range: 200Ω; 2kΩ; 20kΩ; 200kΩ; 2MΩ; 20MΩ; 100MΩ DC current measuring range: 200mA; 10A DC voltage measuring range: 200mV; 2V; 20V; 200V; 1kV AC voltage measuring range: 200mV; 2V; 20V; 200V; 750V Capacitance measuring range: 20nF; 200nF; 2µF; 20µF; 200µF; 2mF Memory record length: 8kpts Capacitance measuring accuracy: ±(3%+ 10 digit) AC current measuring accuracy: ±(1% + 10 digit) DC voltage measuring accuracy: ±(0.3% + 5 digit); ±(0.3% + 10 digit) @200mV DC current measuring accuracy: ±(0.8% + 10 digit) AC voltage measuring accuracy: ±(0.8% + 10 digit); ±(1% + 10 digit) @750V Resistance measuring accuracy: ±(0.8%+3 digit) |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|