KEW1051 KYORITSU
Hersteller: KYORITSUCategory: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Kind of display used: LCD
Type of meter: digital multimeter
True effective value measurement: True RMS
Bargraph: yes
Temperature measuring range: -50...600°C
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF
AC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A
DC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Diode test: 0.5mA @2V
Frequency measuring accuracy: ±(0.02%+1 digit)
Frequency measuring range: 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
AC voltage measuring accuracy: ±(0.5% + 5 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
Dimensions (W x H x D): 90x192x49mm
Resistance measuring accuracy: ±(0.4%+1 digit)
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
Temperature measurement accuracy: ±(2% + 3°C)
DC current measuring accuracy: ±(0.2% + 5 digit)
AC current measuring accuracy: ±(0.75% + 5 digit)
Capacitance measuring accuracy: ±(2%+ 5 digit)
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Display parameters: (6000)
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Continuity test: acoustic indication; <50Ω
Measuring instrument features: automatic power-off; HOLD function; low-pass filter; MIN/MAX/LAST function
Standard equipment: fuses x2; test leads; user's manual
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 1+ | 435.05 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details KEW1051 KYORITSU
Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV, Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010, Kind of display used: LCD, Type of meter: digital multimeter, True effective value measurement: True RMS, Bargraph: yes, Temperature measuring range: -50...600°C, Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF, AC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A, DC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A, DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, Diode test: 0.5mA @2V, Frequency measuring accuracy: ±(0.02%+1 digit), Frequency measuring range: 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz, AC voltage measuring accuracy: ±(0.5% + 5 digit), DC voltage measuring accuracy: ±(0.09% + 2 digit), Dimensions (W x H x D): 90x192x49mm, Resistance measuring accuracy: ±(0.4%+1 digit), Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ, Temperature measurement accuracy: ±(2% + 3°C), DC current measuring accuracy: ±(0.2% + 5 digit), AC current measuring accuracy: ±(0.75% + 5 digit), Capacitance measuring accuracy: ±(2%+ 5 digit), Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12, Display parameters: (6000), Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Continuity test: acoustic indication; .
Weitere Produktangebote KEW1051 nach Preis ab 435.05 EUR bis 435.05 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
|---|---|---|---|---|---|---|---|---|---|
|
KEW1051 | Hersteller : KYORITSU |
Category: Portable digital multimetersDescription: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Kind of display used: LCD Type of meter: digital multimeter True effective value measurement: True RMS Bargraph: yes Temperature measuring range: -50...600°C Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF AC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A DC current measuring range: 600µA; 6mA; 60mA; 440mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Diode test: 0.5mA @2V Frequency measuring accuracy: ±(0.02%+1 digit) Frequency measuring range: 99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz AC voltage measuring accuracy: ±(0.5% + 5 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) Dimensions (W x H x D): 90x192x49mm Resistance measuring accuracy: ±(0.4%+1 digit) Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ Temperature measurement accuracy: ±(2% + 3°C) DC current measuring accuracy: ±(0.2% + 5 digit) AC current measuring accuracy: ±(0.75% + 5 digit) Capacitance measuring accuracy: ±(2%+ 5 digit) Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12 Display parameters: (6000) Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Continuity test: acoustic indication; <50Ω Measuring instrument features: automatic power-off; HOLD function; low-pass filter; MIN/MAX/LAST function Standard equipment: fuses x2; test leads; user's manual Battery/ rechargeable battery: battery LR6 AA 1,5V x4 |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|