LA 100-P LEM
Hersteller: LEM
Board Mount Current Sensors Current Transducer LA 100-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
| Anzahl | Privatkunde |
|---|---|
| 1+ | 61.04 EUR |
| 5+ | 51.46 EUR |
| 10+ | 47.84 EUR |
| 25+ | 43.41 EUR |
| 50+ | 40.34 EUR |
| 100+ | 39.19 EUR |
Artikel auf Bestellung
Nicht an unserem Lager — wir beziehen ihn nach Ihrer Bestellung vom Lieferantenlager.
Lieferzeit:
10-14 Tag (e)
Produktrezensionen
Produktbewertung abgeben
Technische Details LA 100-P LEM
Description: LEM - LA 100-P - Stromwandler, Baureihe LA, 10A, -150A bis 150A, 0.7%, geschlossene Schleife, 12V DC bis 15V DC, tariffCode: 90303370, euEccn: NLR, rohsCompliant: YES, Versorgungsspannung: ± 12V bis ± 15V, hazardous: false, rohsPhthalatesCompliant: YES, Sekundärsignal: 50V, isCanonical: Y, Gemessener Strom: AC / DC / gepulst, Betriebstemperatur, min.: -40°C, Sensormontage: Durchsteckmontage, Sensorausgang: Geschlossene Schleife, Strommessbereich DC: -150A bis 150A, DC-Versorgungsspannung: ± 12V bis ± 15V, SVHC: No SVHC (25-Jun-2025), DC-Versorgungsspannung, max.: 15V, DC-Versorgungsspannung, min.: 12V, Produktpalette: LA100P Series, productTraceability: No, Genauigkeit: 0.45%, usEccn: EAR99, Primärstrom: 100A, Betriebstemperatur, max.: 85°C, Genauigkeit %: 0.7%, Strommessbereich AC: -150A bis 150A, Stromsensortechnologie: Hall-Effekt, Closed-Loop.
Weitere Produktangebote LA 100-P nach Preis ab 42.92 EUR bis 86.04 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Privatkunde | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
LA 100-P | LEM USA Inc. |
Description: CURRENT SENSOR HE/CL 100APackaging: Bulk Package / Case: Module, Single Pass Through Polarization: Bidirectional Mounting Type: Through Hole Output: Ratiometric, Current Frequency: DC ~ 200kHz Accuracy: ±0.45% Operating Temperature: -40°C ~ 85°C Voltage - Supply: ±12V ~ 15V Response Time: 1µs Sensor Type: Hall Effect, Closed Loop Linearity: ±0.15% For Measuring: AC/DC Current - Supply (Max): 10mA Current - Sensing: 100A Part Status: Active Number of Channels: 1 |
auf Bestellung 769 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||||||||||
|
LA 100-P | LEM |
Description: LEM - LA 100-P - Stromwandler, Baureihe LA, 10A, -150A bis 150A, 0.7%, geschlossene Schleife, 12V DC bis 15V DCtariffCode: 90303370 euEccn: NLR rohsCompliant: YES Versorgungsspannung: ± 12V bis ± 15V hazardous: false rohsPhthalatesCompliant: YES Sekundärsignal: 50V isCanonical: Y Gemessener Strom: AC / DC / gepulst Betriebstemperatur, min.: -40°C Sensormontage: Durchsteckmontage Sensorausgang: Geschlossene Schleife Strommessbereich DC: -150A bis 150A DC-Versorgungsspannung: ± 12V bis ± 15V SVHC: No SVHC (25-Jun-2025) DC-Versorgungsspannung, max.: 15V DC-Versorgungsspannung, min.: 12V Produktpalette: LA100P Series productTraceability: No Genauigkeit: 0.45% usEccn: EAR99 Primärstrom: 100A Betriebstemperatur, max.: 85°C Genauigkeit %: 0.7% Strommessbereich AC: -150A bis 150A Stromsensortechnologie: Hall-Effekt, Closed-Loop |
auf Bestellung 500 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||||||||||
| LA100P | IDT |
auf Bestellung 2100 Stücke: Lieferzeit 21-28 Tag (e) |
Im Einkaufswagen Stück im Wert von UAH |
| LA 100-P |
![]() |
Hersteller: LEM USA Inc.
Description: CURRENT SENSOR HE/CL 100A
Packaging: Bulk
Package / Case: Module, Single Pass Through
Polarization: Bidirectional
Mounting Type: Through Hole
Output: Ratiometric, Current
Frequency: DC ~ 200kHz
Accuracy: ±0.45%
Operating Temperature: -40°C ~ 85°C
Voltage - Supply: ±12V ~ 15V
Response Time: 1µs
Sensor Type: Hall Effect, Closed Loop
Linearity: ±0.15%
For Measuring: AC/DC
Current - Supply (Max): 10mA
Current - Sensing: 100A
Part Status: Active
Number of Channels: 1
Description: CURRENT SENSOR HE/CL 100A
Packaging: Bulk
Package / Case: Module, Single Pass Through
Polarization: Bidirectional
Mounting Type: Through Hole
Output: Ratiometric, Current
Frequency: DC ~ 200kHz
Accuracy: ±0.45%
Operating Temperature: -40°C ~ 85°C
Voltage - Supply: ±12V ~ 15V
Response Time: 1µs
Sensor Type: Hall Effect, Closed Loop
Linearity: ±0.15%
For Measuring: AC/DC
Current - Supply (Max): 10mA
Current - Sensing: 100A
Part Status: Active
Number of Channels: 1
auf Bestellung 769 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 1+ | 54.45 EUR |
| 5+ | 49.8 EUR |
| 10+ | 48.08 EUR |
| 25+ | 46.02 EUR |
| 50+ | 44.61 EUR |
| 125+ | 42.92 EUR |
| LA 100-P |
![]() |
Hersteller: LEM
Description: LEM - LA 100-P - Stromwandler, Baureihe LA, 10A, -150A bis 150A, 0.7%, geschlossene Schleife, 12V DC bis 15V DC
tariffCode: 90303370
euEccn: NLR
rohsCompliant: YES
Versorgungsspannung: ± 12V bis ± 15V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 50V
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Geschlossene Schleife
Strommessbereich DC: -150A bis 150A
DC-Versorgungsspannung: ± 12V bis ± 15V
SVHC: No SVHC (25-Jun-2025)
DC-Versorgungsspannung, max.: 15V
DC-Versorgungsspannung, min.: 12V
Produktpalette: LA100P Series
productTraceability: No
Genauigkeit: 0.45%
usEccn: EAR99
Primärstrom: 100A
Betriebstemperatur, max.: 85°C
Genauigkeit %: 0.7%
Strommessbereich AC: -150A bis 150A
Stromsensortechnologie: Hall-Effekt, Closed-Loop
Description: LEM - LA 100-P - Stromwandler, Baureihe LA, 10A, -150A bis 150A, 0.7%, geschlossene Schleife, 12V DC bis 15V DC
tariffCode: 90303370
euEccn: NLR
rohsCompliant: YES
Versorgungsspannung: ± 12V bis ± 15V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 50V
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Geschlossene Schleife
Strommessbereich DC: -150A bis 150A
DC-Versorgungsspannung: ± 12V bis ± 15V
SVHC: No SVHC (25-Jun-2025)
DC-Versorgungsspannung, max.: 15V
DC-Versorgungsspannung, min.: 12V
Produktpalette: LA100P Series
productTraceability: No
Genauigkeit: 0.45%
usEccn: EAR99
Primärstrom: 100A
Betriebstemperatur, max.: 85°C
Genauigkeit %: 0.7%
Strommessbereich AC: -150A bis 150A
Stromsensortechnologie: Hall-Effekt, Closed-Loop
auf Bestellung 500 Stücke:
Lieferzeit 14-21 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 3+ | 86.04 EUR |
| 10+ | 78.29 EUR |
| 50+ | 70.79 EUR |
| LA100P |
Hersteller: IDT
auf Bestellung 2100 Stücke:
Lieferzeit 21-28 Tag (e)