METRACAL MC GOSSEN METRAWATT

Category: Calibrators
Description: Meter: multimeter calibrator; Diode test: 1mA@3.2V; frequency
Type of meter: multimeter calibrator
Measurement: 0-20mA current loop; 0-24mA current loop; 4-20mA current loop; AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: 4,75 digit; (30000)
DC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V
DC voltage measuring accuracy: ±(0.05% + 10 digit)
AC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V
AC voltage measuring accuracy: ±(0.2% + 30 digit)
Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ
Capacitance measuring range: 30nF; 300nF; 3µF; 30µF; 300µF
Capacitance measuring accuracy: ±(1%+ 6 digit)
Resistance measuring accuracy: ±(0.1%+5 digit)
Continuity test: acoustic indication; <300Ω
Power supply: battery LR6 AA 1,5V x2
Standard equipment: calibration certificate DAkkS; carrying strap; holster; test leads ( 3pcs.); user's manual
Conform to the norm: CAT II 600V; EN 61010
Measuring instrument features: dual mode – simultaneous calibration and measurement; frequency generator; HOLD function; MIN/MAX function; operates with thermocouple types: J, K, T, S, B, E, N, L, U, R, Pt100, PT1000, Ni100, Ni1000
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Interface: IR (option)
Memory capacity: 16Mb
Dimensions: 200x87x45mm
Additional functions: calibrator; data logger; multimeter; simulator
True effective value measurement: True RMS AC
Producer guarantee (months): 36
AC current measuring range: 0.3mA; 3mA; 30mA; 300mA
DC current measuring range: 0.3mA; 3mA; 30mA; 300mA
Frequency measuring range: 300Hz; 3kHz; 30kHz; 300kHz
Diode test: 1mA @3.2V
Software: LabVIEW
Current source: 0...24mA
Frequency measuring accuracy: ±(0.05%+5 digit)
AC current measuring accuracy: ±(0.015% + 0.005% range); ±(0.5% + 30 digit)
DC current measuring accuracy: ±(0.05% + 15 digit)
Kind of calibrator: current; frequency; loop; resistance; RTD; thermocouple; voltage
IP rating: IP65
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
Produktrezensionen
Produktbewertung abgeben
Technische Details METRACAL MC GOSSEN METRAWATT
Category: Calibrators, Description: Meter: multimeter calibrator; Diode test: 1mA@3.2V; frequency, Type of meter: multimeter calibrator, Measurement: 0-20mA current loop; 0-24mA current loop; 4-20mA current loop; AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature, Kind of display used: LCD, Display parameters: 4,75 digit; (30000), DC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V, DC voltage measuring accuracy: ±(0.05% + 10 digit), AC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V, AC voltage measuring accuracy: ±(0.2% + 30 digit), Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ, Capacitance measuring range: 30nF; 300nF; 3µF; 30µF; 300µF, Capacitance measuring accuracy: ±(1%+ 6 digit), Resistance measuring accuracy: ±(0.1%+5 digit), Continuity test: acoustic indication; .
Weitere Produktangebote METRACAL MC
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
---|---|---|---|---|---|
![]() +2 |
METRACAL MC | Hersteller : GOSSEN METRAWATT |
![]() Description: Meter: multimeter calibrator; Diode test: 1mA@3.2V; frequency Type of meter: multimeter calibrator Measurement: 0-20mA current loop; 0-24mA current loop; 4-20mA current loop; AC current; AC voltage; capacitance; continuity; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: 4,75 digit; (30000) DC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V DC voltage measuring accuracy: ±(0.05% + 10 digit) AC voltage measuring range: 60mV; 300mV; 3V; 30V; 300V AC voltage measuring accuracy: ±(0.2% + 30 digit) Resistance measuring range: 300Ω; 3kΩ; 30kΩ; 300kΩ; 3MΩ; 30MΩ Capacitance measuring range: 30nF; 300nF; 3µF; 30µF; 300µF Capacitance measuring accuracy: ±(1%+ 6 digit) Resistance measuring accuracy: ±(0.1%+5 digit) Continuity test: acoustic indication; <300Ω Power supply: battery LR6 AA 1,5V x2 Standard equipment: calibration certificate DAkkS; carrying strap; holster; test leads ( 3pcs.); user's manual Conform to the norm: CAT II 600V; EN 61010 Measuring instrument features: dual mode – simultaneous calibration and measurement; frequency generator; HOLD function; MIN/MAX function; operates with thermocouple types: J, K, T, S, B, E, N, L, U, R, Pt100, PT1000, Ni100, Ni1000 Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Interface: IR (option) Memory capacity: 16Mb Dimensions: 200x87x45mm Additional functions: calibrator; data logger; multimeter; simulator True effective value measurement: True RMS AC Producer guarantee (months): 36 AC current measuring range: 0.3mA; 3mA; 30mA; 300mA DC current measuring range: 0.3mA; 3mA; 30mA; 300mA Frequency measuring range: 300Hz; 3kHz; 30kHz; 300kHz Diode test: 1mA @3.2V Software: LabVIEW Current source: 0...24mA Frequency measuring accuracy: ±(0.05%+5 digit) AC current measuring accuracy: ±(0.015% + 0.005% range); ±(0.5% + 30 digit) DC current measuring accuracy: ±(0.05% + 15 digit) Kind of calibrator: current; frequency; loop; resistance; RTD; thermocouple; voltage IP rating: IP65 |
Produkt ist nicht verfügbar |