PROFITEST MXTRA IQ GOSSEN METRAWATT

Category: PV and EVSE Testers and Meters
Description: Meter: appliance meter; VAC accuracy: ±(2%+1digit); 300mV÷600V
Kind of display used: LCD
Measurement: AC voltage; contact voltage without tripping the RCCB; earthing resistance; Ground loop resistance; ground resistivity; insulation resistance; leakage current; phase sequence; RCD tripping time; votlage drop
AC voltage measuring range: 300mV...600V
IP rating: IP40
Conform to the norm: CAT III 500V; CAT IV 300V; EN 61010; VDE 0411
Measuring instrument features: automatic test sequence; low battery indicator; simulation of operating states of electric vehicles at electric charging stations
Manufacturer series: PROFITEST
Operating temperature: -5...50°C
Standard equipment: 2 crocodile clips; 2-pole measuring adapter with expansion cable; battery charger; calibration certificate DAkkS; carrying strap; USB cable; user's manual
Earthing resistance measuring range: 0.1...9.99kΩ
Body dimensions: 260x330x90mm
AC voltage measuring accuracy: ±(2% + 1 digit)
Earthing resistance measuring accuracy: ±(5% + 3 digit)
Measurement memory: 50000
Insulation resistance measuring ranges: 50kΩ...499MΩ
Test: IMD; N-PE reversal; RCM; residual current circuit breakers
RCD test: general purpose
Type of meter: appliance meter
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x8
Interface: Bluetooth; RS232; USB
Connectors for the country: Europe
Related items: GM-GTZ3196000R0001; GM-Z502H; GM-Z502R; GM-Z503F; GM-Z503G; GM-Z503W; GM-Z503X; GM-Z503Y
Software: IZYTRONIQ BUSINESS Starter
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
Produktrezensionen
Produktbewertung abgeben
Technische Details PROFITEST MXTRA IQ GOSSEN METRAWATT
Category: PV and EVSE Testers and Meters, Description: Meter: appliance meter; VAC accuracy: ±(2%+1digit); 300mV÷600V, Kind of display used: LCD, Measurement: AC voltage; contact voltage without tripping the RCCB; earthing resistance; Ground loop resistance; ground resistivity; insulation resistance; leakage current; phase sequence; RCD tripping time; votlage drop, AC voltage measuring range: 300mV...600V, IP rating: IP40, Conform to the norm: CAT III 500V; CAT IV 300V; EN 61010; VDE 0411, Measuring instrument features: automatic test sequence; low battery indicator; simulation of operating states of electric vehicles at electric charging stations, Manufacturer series: PROFITEST, Operating temperature: -5...50°C, Standard equipment: 2 crocodile clips; 2-pole measuring adapter with expansion cable; battery charger; calibration certificate DAkkS; carrying strap; USB cable; user's manual, Earthing resistance measuring range: 0.1...9.99kΩ, Body dimensions: 260x330x90mm, AC voltage measuring accuracy: ±(2% + 1 digit), Earthing resistance measuring accuracy: ±(5% + 3 digit), Measurement memory: 50000, Insulation resistance measuring ranges: 50kΩ...499MΩ, Test: IMD; N-PE reversal; RCM; residual current circuit breakers, RCD test: general purpose, Type of meter: appliance meter, Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x8, Interface: Bluetooth; RS232; USB, Connectors for the country: Europe, Related items: GM-GTZ3196000R0001; GM-Z502H; GM-Z502R; GM-Z503F; GM-Z503G; GM-Z503W; GM-Z503X; GM-Z503Y, Software: IZYTRONIQ BUSINESS Starter, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote PROFITEST MXTRA IQ
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
---|---|---|---|---|---|
![]() +1 |
PROFITEST MXTRA IQ | Hersteller : GOSSEN METRAWATT |
![]() Description: Meter: appliance meter; VAC accuracy: ±(2%+1digit); 300mV÷600V Kind of display used: LCD Measurement: AC voltage; contact voltage without tripping the RCCB; earthing resistance; Ground loop resistance; ground resistivity; insulation resistance; leakage current; phase sequence; RCD tripping time; votlage drop AC voltage measuring range: 300mV...600V IP rating: IP40 Conform to the norm: CAT III 500V; CAT IV 300V; EN 61010; VDE 0411 Measuring instrument features: automatic test sequence; low battery indicator; simulation of operating states of electric vehicles at electric charging stations Manufacturer series: PROFITEST Operating temperature: -5...50°C Standard equipment: 2 crocodile clips; 2-pole measuring adapter with expansion cable; battery charger; calibration certificate DAkkS; carrying strap; USB cable; user's manual Earthing resistance measuring range: 0.1...9.99kΩ Body dimensions: 260x330x90mm AC voltage measuring accuracy: ±(2% + 1 digit) Earthing resistance measuring accuracy: ±(5% + 3 digit) Measurement memory: 50000 Insulation resistance measuring ranges: 50kΩ...499MΩ Test: IMD; N-PE reversal; RCM; residual current circuit breakers RCD test: general purpose Type of meter: appliance meter Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x8 Interface: Bluetooth; RS232; USB Connectors for the country: Europe Related items: GM-GTZ3196000R0001; GM-Z502H; GM-Z502R; GM-Z503F; GM-Z503G; GM-Z503W; GM-Z503X; GM-Z503Y Software: IZYTRONIQ BUSINESS Starter |
Produkt ist nicht verfügbar |