Description: KEYSIGHT TECHNOLOGIES - U3606B - Digitalmultimeter, Tisch, 120000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 1kV, 3A, 5.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 750V
Messwert Widerstand, max.: 0.1Gohm
Messwert Gleichstrom, max.: 3A
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: YES
usEccn: 3A992.a
euEccn: NLR
Anzahl der Stellen: 5.5
Produktpalette: U3600 Series
productTraceability: No
Messwert Wechselstrom, max.: 3A
auf Bestellung 5 Stücke:

Lieferzeit 14-21 Tag (e)
Produktrezensionen
Produktbewertung abgeben

Technische Details U3606B KEYSIGHT TECHNOLOGIES

Category: Benchtop digital multimeters, Description: Benchtop multimeter with DC power supply; VFD; True RMS AC, Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 11059A; 11062A; 34133A; 34136A; 82350B; 82357B; E3600A-100; E5810A; U8201A; U8202A, Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use., Standard equipment: calibration certificate; mains cable; U8201A test lead kit; USB cable, Kind of display used: VFD, Supply voltage: 100...240V AC, Output voltage: 0...30V DC, Output current: 0...1A, Interface: GPIB; IEEE-488; USB, Number of channels: 1, Output voltage 2: 0...8V DC, Kind of output connector: GPIB socket; USB B socket, Dimensions: 226x105x334mm, Protection: anti-overload OPP; anti-overvoltage OVP, Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEDIUM function, Type of meter: benchtop multimeter with DC power supply, Continuity test: acoustic indication, Duty cycle factor: 0.001...100%, Pollution degree: 2, Output current 2: 0...3A, Output voltage resolution: 1mV, Output current resolution: 0.1mA, Plug variant: EU, True effective value measurement: True RMS AC, Measurement: AC current; AC voltage; capacitance; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; resistance (2-wire); resistance (4-wire), Voltage (regulated) ripple and noise: ≤2mVrms, AC current measuring range: 10mA; 100mA; 1A; 3A, Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ, DC current measuring range: 10mA; 100mA; 1A; 3A, DC voltage measuring range: 19.99mV; 100mV; 1V; 10V; 100V; 1kV, AC voltage measuring range: 100mV; 1V; 10V; 100V; 750V, Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF, Diode test: 0.83mA @1V, Display parameters: 5,5 digit, Capacitance measuring accuracy: ±(1%+ 0.5% range), AC current measuring accuracy: ±(0.5% + 0.1% range), DC voltage measuring accuracy: ±(0.012% + 0.005% range), DC current measuring accuracy: ±(0.05% + 0.005% range), AC voltage measuring accuracy: ±(0.2% + 0.1% range), Resistance measuring accuracy: ±(0.05%+0.005% range), Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote U3606B

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis ohne MwSt
U3606B U3606B Hersteller : KEYSIGHT TECHNOLOGIES U3606-90054.pdf Category: Benchtop digital multimeters
Description: Benchtop multimeter with DC power supply; VFD; True RMS AC
Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 11059A; 11062A; 34133A; 34136A; 82350B; 82357B; E3600A-100; E5810A; U8201A; U8202A
Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use.
Standard equipment: calibration certificate; mains cable; U8201A test lead kit; USB cable
Kind of display used: VFD
Supply voltage: 100...240V AC
Output voltage: 0...30V DC
Output current: 0...1A
Interface: GPIB; IEEE-488; USB
Number of channels: 1
Output voltage 2: 0...8V DC
Kind of output connector: GPIB socket; USB B socket
Dimensions: 226x105x334mm
Protection: anti-overload OPP; anti-overvoltage OVP
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEDIUM function
Type of meter: benchtop multimeter with DC power supply
Continuity test: acoustic indication
Duty cycle factor: 0.001...100%
Pollution degree: 2
Output current 2: 0...3A
Output voltage resolution: 1mV
Output current resolution: 0.1mA
Plug variant: EU
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; resistance (2-wire); resistance (4-wire)
Voltage (regulated) ripple and noise: ≤2mVrms
AC current measuring range: 10mA; 100mA; 1A; 3A
Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 10mA; 100mA; 1A; 3A
DC voltage measuring range: 19.99mV; 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 750V
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 0.83mA @1V
Display parameters: 5,5 digit
Capacitance measuring accuracy: ±(1%+ 0.5% range)
AC current measuring accuracy: ±(0.5% + 0.1% range)
DC voltage measuring accuracy: ±(0.012% + 0.005% range)
DC current measuring accuracy: ±(0.05% + 0.005% range)
AC voltage measuring accuracy: ±(0.2% + 0.1% range)
Resistance measuring accuracy: ±(0.05%+0.005% range)
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
U3606B U3606B Hersteller : KEYSIGHT TECHNOLOGIES U3606-90054.pdf Category: Benchtop digital multimeters
Description: Benchtop multimeter with DC power supply; VFD; True RMS AC
Related items: 10833A; 10833B; 10833C; 10833D; 10833F; 10833G; 11059A; 11062A; 34133A; 34136A; 82350B; 82357B; E3600A-100; E5810A; U8201A; U8202A
Information: Products are intended for professional and industrial use only, and are not suitable for consumer or household use.
Standard equipment: calibration certificate; mains cable; U8201A test lead kit; USB cable
Kind of display used: VFD
Supply voltage: 100...240V AC
Output voltage: 0...30V DC
Output current: 0...1A
Interface: GPIB; IEEE-488; USB
Number of channels: 1
Output voltage 2: 0...8V DC
Kind of output connector: GPIB socket; USB B socket
Dimensions: 226x105x334mm
Protection: anti-overload OPP; anti-overvoltage OVP
Measuring instrument features: auto and manual ranging; HOLD function; MIN/MAX/MEDIUM function
Type of meter: benchtop multimeter with DC power supply
Continuity test: acoustic indication
Duty cycle factor: 0.001...100%
Pollution degree: 2
Output current 2: 0...3A
Output voltage resolution: 1mV
Output current resolution: 0.1mA
Plug variant: EU
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; dB; dBm; DC current; DC voltage; duty cycle; frequency; resistance; resistance (2-wire); resistance (4-wire)
Voltage (regulated) ripple and noise: ≤2mVrms
AC current measuring range: 10mA; 100mA; 1A; 3A
Resistance measuring range: 100Ω; 1kΩ; 10kΩ; 100kΩ; 1MΩ; 10MΩ; 100MΩ
DC current measuring range: 10mA; 100mA; 1A; 3A
DC voltage measuring range: 19.99mV; 100mV; 1V; 10V; 100V; 1kV
AC voltage measuring range: 100mV; 1V; 10V; 100V; 750V
Capacitance measuring range: 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF
Diode test: 0.83mA @1V
Display parameters: 5,5 digit
Capacitance measuring accuracy: ±(1%+ 0.5% range)
AC current measuring accuracy: ±(0.5% + 0.1% range)
DC voltage measuring accuracy: ±(0.012% + 0.005% range)
DC current measuring accuracy: ±(0.05% + 0.005% range)
AC voltage measuring accuracy: ±(0.2% + 0.1% range)
Resistance measuring accuracy: ±(0.05%+0.005% range)
Produkt ist nicht verfügbar