Produkte > UNI-T > UT219DS
UT219DS
  • UT219DS
  • UT219DS
  • UT219DS
  • UT219DS
  • UT219DS
  • UT219DS

UT219DS UNI-T


pVersion=0046&contRep=ZT&docId=005056AB281E1EDEBB8307FFF5A3C0D6&compId=UT219M.pdf?ci_sign=32312aaaf5603b254d8aeaeb4e14bcb3a79dc0a1 pVersion=0046&contRep=ZT&docId=005056AB281E1EDEBB830815581A40D6&compId=UT219M-UM.pdf?ci_sign=269d635c4f6b909862357dde36f7ee91580400e1 pVersion=0046&contRep=ZT&docId=005056AB752F1EE693CFA9A7C905EFA8&compId=ut204_en.pdf?ci_sign=22ab97746e66fb73159ae9f1b22a57d12d9d6a56 Hersteller: UNI-T
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 33mm; LCD
Measuring instrument features: auto and manual ranging; automatic power-off; built-in torch; display zeroing function; HOLD function; low battery indicator; low input impedance function (LoZ); low-pass filter; MIN/MAX/REL function
Test: diodes
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: case; temperature probe; test leads
Resistance to: fall from 2m height
Type of meter: multifunction
Kind of meter: digital; pincers type
Software: included
IP rating: IP54
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Bargraph: yes
Temperature measuring range: -40...1000°C
DC current measuring range: 60A; 600A
Capacitance measuring range: 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
AC current measuring range: 60A; 600A
DC voltage measuring range: 1mV...6V; 60V; 600V
AC voltage measuring range: 1mV...6V; 60V; 600V
Max. diameter of measured cable: 33mm
Dimensions: 234.6x82x47mm
Duty cycle factor: 0.1...99.9%
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring accuracy: ±(0.6% + 3 digit)
AC voltage measuring accuracy: ±(1% + 6 digit)
Resistance measuring accuracy: ±(1%+3 digit)
DC current measuring accuracy: ±(1.8% + 6 digit)
AC current measuring accuracy: ±(1.8% + 6 digit)
Pollution degree: 2
Diode test: 3V
Weight with battery: 310g
Frequency measuring range: 60...40MHz
Display parameters: (6000)
Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; duty cycle; frequency; inrush current; resistance; temperature
Continuity test: acoustic indication
Conform to the norm: CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 17 Stücke:

Lieferzeit 7-14 Tag (e)
Anzahl Preis
1+157.36 EUR
3+150.72 EUR
Im Einkaufswagen  Stück im Wert von  UAH
Produktrezensionen
Produktbewertung abgeben

Technische Details UT219DS UNI-T

Category: Meters and AC/DC Clamp Probes, Description: Meter: multifunction; digital,pincers type; Øcable: 33mm; LCD, Measuring instrument features: auto and manual ranging; automatic power-off; built-in torch; display zeroing function; HOLD function; low battery indicator; low input impedance function (LoZ); low-pass filter; MIN/MAX/REL function, Test: diodes, Battery/ rechargeable battery: battery LR03 AAA 1,5V x3, Power supply: battery LR03 AAA 1,5V x3, Standard equipment: case; temperature probe; test leads, Resistance to: fall from 2m height, Type of meter: multifunction, Kind of meter: digital; pincers type, Software: included, IP rating: IP54, Kind of display used: LCD, Illumination: yes, True effective value measurement: True RMS, Bargraph: yes, Temperature measuring range: -40...1000°C, DC current measuring range: 60A; 600A, Capacitance measuring range: 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF, AC current measuring range: 60A; 600A, DC voltage measuring range: 1mV...6V; 60V; 600V, AC voltage measuring range: 1mV...6V; 60V; 600V, Max. diameter of measured cable: 33mm, Dimensions: 234.6x82x47mm, Duty cycle factor: 0.1...99.9%, Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ, DC voltage measuring accuracy: ±(0.6% + 3 digit), AC voltage measuring accuracy: ±(1% + 6 digit), Resistance measuring accuracy: ±(1%+3 digit), DC current measuring accuracy: ±(1.8% + 6 digit), AC current measuring accuracy: ±(1.8% + 6 digit), Pollution degree: 2, Diode test: 3V, Weight with battery: 310g, Frequency measuring range: 60...40MHz, Display parameters: (6000), Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; duty cycle; frequency; inrush current; resistance; temperature, Continuity test: acoustic indication, Conform to the norm: CAT IV 600V; EN 61010, Anzahl je Verpackung: 1 Stücke.

Weitere Produktangebote UT219DS nach Preis ab 150.72 EUR bis 157.36 EUR

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis
UT219DS
+5
UT219DS Hersteller : UNI-T pVersion=0046&contRep=ZT&docId=005056AB281E1EDEBB8307FFF5A3C0D6&compId=UT219M.pdf?ci_sign=32312aaaf5603b254d8aeaeb4e14bcb3a79dc0a1 pVersion=0046&contRep=ZT&docId=005056AB281E1EDEBB830815581A40D6&compId=UT219M-UM.pdf?ci_sign=269d635c4f6b909862357dde36f7ee91580400e1 pVersion=0046&contRep=ZT&docId=005056AB752F1EE693CFA9A7C905EFA8&compId=ut204_en.pdf?ci_sign=22ab97746e66fb73159ae9f1b22a57d12d9d6a56 Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,pincers type; Øcable: 33mm; LCD
Measuring instrument features: auto and manual ranging; automatic power-off; built-in torch; display zeroing function; HOLD function; low battery indicator; low input impedance function (LoZ); low-pass filter; MIN/MAX/REL function
Test: diodes
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: case; temperature probe; test leads
Resistance to: fall from 2m height
Type of meter: multifunction
Kind of meter: digital; pincers type
Software: included
IP rating: IP54
Kind of display used: LCD
Illumination: yes
True effective value measurement: True RMS
Bargraph: yes
Temperature measuring range: -40...1000°C
DC current measuring range: 60A; 600A
Capacitance measuring range: 60nF; 600nF; 6µF; 60µF; 600µF; 6mF; 60mF
AC current measuring range: 60A; 600A
DC voltage measuring range: 1mV...6V; 60V; 600V
AC voltage measuring range: 1mV...6V; 60V; 600V
Max. diameter of measured cable: 33mm
Dimensions: 234.6x82x47mm
Duty cycle factor: 0.1...99.9%
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC voltage measuring accuracy: ±(0.6% + 3 digit)
AC voltage measuring accuracy: ±(1% + 6 digit)
Resistance measuring accuracy: ±(1%+3 digit)
DC current measuring accuracy: ±(1.8% + 6 digit)
AC current measuring accuracy: ±(1.8% + 6 digit)
Pollution degree: 2
Diode test: 3V
Weight with battery: 310g
Frequency measuring range: 60...40MHz
Display parameters: (6000)
Measurement: AC current; AC voltage; capacitance; continuity; DC voltage; duty cycle; frequency; inrush current; resistance; temperature
Continuity test: acoustic indication
Conform to the norm: CAT IV 600V; EN 61010
auf Bestellung 17 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis
1+157.36 EUR
3+150.72 EUR
Im Einkaufswagen  Stück im Wert von  UAH