UT8803E UNI-T

Category: Benchtop digital multimeters
Description: Benchtop multimeter; EBTN; 3,5 digit (6000); Illumin: yes
Supply voltage: 100...240V AC
Interface: USB
Conform to the norm: CAT II 600V; EN 61010
Illumination: yes
Dimensions: 265x110x320mm
Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12
Standard equipment: mains cable; temperature probe; test leads; test leads with crocodile clips; USB cable
Measuring instrument features: auto and manual ranging; automatic polarization selection; HOLD function; MIN/MAX function; overflow indicator; REL function
Type of meter: benchtop multimeter
Test: diodes
Continuity test: acoustic indication
Duty cycle factor: 5...95%
Temperature measuring range: -40...1000°C
True effective value measurement: True RMS
Bargraph: yes
Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; inductance; resistance; temperature
Inductance measuring range: 0.1...600µH; 6mH; 60mH; 600mH; 6H; 60H; 100H
AC current measuring range: 600µA; 6mA; 60mA; 600mA; 10A
Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ
DC current measuring range: 600µA; 6mA; 60mA; 600mA; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 750V
Frequency measuring range: 600Hz; 6kHz; 60kHz; 600kHz; 6MHz; 20MHz
Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF
Software: included
Display parameters: 3,5 digit (6000)
Frequency measuring accuracy: ±(0.1%+10 digit)
Capacitance measuring accuracy: ±(1.5%+ 5 digit)
Inductance measuring accuracy: ±(2% + 5 digit)
AC current measuring accuracy: ±(1% + 5 digit)
DC voltage measuring accuracy: ±(0.3% + 2 digit)
DC current measuring accuracy: ±(0.8% + 3 digit)
AC voltage measuring accuracy: ±(0.6% + 5 digit)
Resistance measuring accuracy: ±(0.8%+5 digit)
Kind of display used: EBTN
auf Bestellung 11 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl | Preis |
---|---|
1+ | 206.85 EUR |
4+ | 201.06 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details UT8803E UNI-T
Category: Benchtop digital multimeters, Description: Benchtop multimeter; EBTN; 3,5 digit (6000); Illumin: yes, Supply voltage: 100...240V AC, Interface: USB, Conform to the norm: CAT II 600V; EN 61010, Illumination: yes, Dimensions: 265x110x320mm, Related items: 5790D; 5793D; 5794D; 5795D; 5797D; BKP60; EX871515; EX881602; EX881603; EX881605; PKT-PTA; PKT-PTF-10; PKT-PTF-20; PKT-PTF-25; PKT-PTF-30; PKT-PTF-40; PKT-PTF-50; PKT-PTF-55; PKT-PTF-56; PKT-PTF-60; SE027; SE028; SE029; SE030; SE031; SE059; SE060; SE061; SE062; SE001; SE002; SE003; SE004; SE000; TESTO-06020393; TESTO-06020645; TESTO-06024592; TESTO-06024892; TESTO-06280020; TESTO-06281292; TESTO-06287533; TP200; TP400; TP870; TP873; TP873-5M; TP882; TP-111; TP-112; TP-02; TP-03; TP-04; TP-06; TP-08; TP-09; TPK-59; TPK-62; UTT10K; UTT12, Standard equipment: mains cable; temperature probe; test leads; test leads with crocodile clips; USB cable, Measuring instrument features: auto and manual ranging; automatic polarization selection; HOLD function; MIN/MAX function; overflow indicator; REL function, Type of meter: benchtop multimeter, Test: diodes, Continuity test: acoustic indication, Duty cycle factor: 5...95%, Temperature measuring range: -40...1000°C, True effective value measurement: True RMS, Bargraph: yes, Measurement: AC current; AC voltage; capacitance; continuity; DC current; DC voltage; duty cycle; frequency; inductance; resistance; temperature, Inductance measuring range: 0.1...600µH; 6mH; 60mH; 600mH; 6H; 60H; 100H, AC current measuring range: 600µA; 6mA; 60mA; 600mA; 10A, Resistance measuring range: 600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 60MΩ, DC current measuring range: 600µA; 6mA; 60mA; 600mA; 10A, DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, AC voltage measuring range: 600mV; 6V; 60V; 600V; 750V, Frequency measuring range: 600Hz; 6kHz; 60kHz; 600kHz; 6MHz; 20MHz, Capacitance measuring range: 6nF; 60nF; 600nF; 6µF; 60µF; 600µF; 6mF, Software: included, Display parameters: 3,5 digit (6000), Frequency measuring accuracy: ±(0.1%+10 digit), Capacitance measuring accuracy: ±(1.5%+ 5 digit), Inductance measuring accuracy: ±(2% + 5 digit), AC current measuring accuracy: ±(1% + 5 digit), DC voltage measuring accuracy: ±(0.3% + 2 digit), DC current measuring accuracy: ±(0.8% + 3 digit), AC voltage measuring accuracy: ±(0.6% + 5 digit), Resistance measuring accuracy: ±(0.8%+5 digit), Kind of display used: EBTN.
Weitere Produktangebote UT8803E nach Preis ab 295.68 EUR bis 295.68 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
---|---|---|---|---|---|---|---|---|---|
![]() |
UT8803E | Hersteller : Uni-Trend Technology US Inc |
![]() Packaging: Tape & Box (TB) Features: Record Display Type: LCD Style: Bench Function: Voltage, Current, Resistance, Capacitance, Temperature, Frequency Type: Digital (DMM) Ranging: Auto Display Count: 6000 Functions, Extra: Continuity, Diode Test Response: True RMS Part Status: Active Display Digits: 3.83 |
auf Bestellung 60 Stücke: Lieferzeit 10-14 Tag (e) |
|