Suchergebnisse für "FLUKE" : > 60

Wählen Sie Seite:   1 2  Nächste Seite >> ]
Art der Ansicht :
Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit
Preis
ohne MwSt
FLUKE 107 FLUKE FLK-107 Portable digital multimeters
auf Bestellung 41 Stücke:
Lieferzeit 7-14 Tag (e)
1+159.73 EUR
FLUKE 113
+5
FLUKE 113 FLUKE Fluke 113 Datasheet EN.pdf Fluke 113 Manual EN.pdf Fluke 113 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Type of meter: digital multimeter
Measurement: capacitance; DC voltage; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 1mV...6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Diode test: 1.2mA @2.7V
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 404g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 84x167x46mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 110
Anzahl je Verpackung: 1 Stücke
auf Bestellung 13 Stücke:
Lieferzeit 7-14 Tag (e)
1+221.36 EUR
Fluke 114
+5
Fluke 114 FLUKE Fluke 114 Datasheet EN.pdf Manual 114-115-117 (EN).pdf 114_____umeng0100.pdf 114_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC voltage; DC voltage; resistance
Dimensions (W x H x D): 84x167x46mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
1+290 EUR
FLUKE 115
+4
FLUKE 115 FLUKE Fluke 115 Datasheet (english).pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5543B; POM-6275; POM-6343
Manufacturer series: Fluke 110
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Anzahl je Verpackung: 1 Stücke
auf Bestellung 33 Stücke:
Lieferzeit 7-14 Tag (e)
1+337.98 EUR
FLUKE 116
+5
FLUKE 116 FLUKE Fluke 116 Datasheet EN.PDF Fluke 116 Manual EN.pdf Fluke 116 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0,1% + 2 digits)
Weight with battery: 550g
Power supply: battery 6LR61 9V x1
Measuring instruments application: heating and air-conditioning technology
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Manufacturer series: Fluke 110
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 84x167x46mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 2583601
Continuity test: acoustic indication; <20Ω
Frequency measuring accuracy: ±(0,1% + 2 digits)
Capacitance measuring accuracy: ±(1,9% + 2 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
AC current measuring accuracy: ±(1,5% + 3 digits)
DC current measuring accuracy: ±(1% + 2 digits)
AC voltage measuring accuracy: ±(1% + 3 digits)
True effective value measurement: True RMS AC
DC voltage measuring accuracy: ±(0,5% + 2 digits)
Bargraph: 33 segm. 32x/s
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Pollution degree: 2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)
1+410.41 EUR
FLUKE 116 FLUKE 116 FLUKE 1780942.pdf Description: FLUKE - FLUKE 116 - Digitalmultimeter, HLK, Baureihe 110, 6000 Zählwerte, TRMS, auto/manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 600V
Messwert Wechselspannung, max.: 600V
Messwert Widerstand, max.: 40Mohm
Messwert Gleichstrom, max.: 600µA
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Widerstand, Temperatur
Produktpalette: 110 Series
productTraceability: No
Messwert Wechselstrom, max.: 600µA
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 116/323
+10
FLUKE 116/323 FLUKE Fluke 116 Datasheet EN.PDF Fluke 116 Manual EN.pdf 32x_____umeng0000.pdf Fluke 116 Manual DE.pdf 32x_____umger0000.pdf Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296029
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
1+606.59 EUR
FLUKE 117
+5
FLUKE 117 FLUKE Fluke 117 Datasheet EN.pdf Manual 114-115-117 (EN).pdf 114_____umeng0100.pdf 114_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)
1+423.41 EUR
FLUKE 117 Fluke ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 46 Stücke:
Lieferzeit 14-21 Tag (e)
1+510.89 EUR
2+ 485.99 EUR
3+ 461.75 EUR
5+ 432.46 EUR
10+ 404.65 EUR
20+ 378.21 EUR
FLUKE 117 Fluke ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 84 Stücke:
Lieferzeit 14-21 Tag (e)
1+510.89 EUR
2+ 485.99 EUR
3+ 461.75 EUR
5+ 432.46 EUR
10+ 404.65 EUR
20+ 378.21 EUR
50+ 353.05 EUR
Fluke 117/323
+7
Fluke 117/323 FLUKE Fluke 117 Datasheet EN.pdf 32x_____umeng0000.pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf 32x_____umger0000.pdf Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296034
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
1+590.28 EUR
FLUKE 117/PRV240 FLUKE 117/PRV240 FLUKE 1965994.pdf?_ga=2.181579303.1803553545.1505114253-1957280463.1504590177 Description: FLUKE - FLUKE 117/PRV240 - Digitalmultimeter, Kit, DMM FLUKE-117 & Prüfeinheit Fluke PRV240
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Fluke 123B
+3
Fluke 123B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
1+2800.96 EUR
Fluke 123B/S
+15
Fluke 123B/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
1+3601.68 EUR
Fluke 124B
+16
Fluke 124B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
1+3361.67 EUR
Fluke 125B
+5
Fluke 125B FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
1+4014.22 EUR
Fluke 125B/S
+16
Fluke 125B/S FLUKE Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
1+4691.5 EUR
FLUKE 1503
+1
FLUKE 1503 FLUKE 10947-eng.pdf Fluke 1507 & 1503 Datasheet EN.pdf 1507____umeng0000.pdf Fluke 1507 & 1503 Manual EN.pdf 1507____umger0000.pdf Fluke 1507 & 1503 Manual DE.pdf Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
1+656.37 EUR
FLUKE 1507
+1
FLUKE 1507 FLUKE 10947-eng.pdf Fluke 1507 & 1503 Datasheet EN.pdf 1507____umeng0000.pdf Fluke 1507 & 1503 Manual EN.pdf 1507____umger0000.pdf Fluke 1507 & 1503 Manual DE.pdf Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)
1+817.67 EUR
FLUKE 1560856 FLUKE 1560856 FLUKE Category: Accessories - Others
Description: Display; FLK-177EGFID
Type of test accessories: display
Related items: FLK-177EGFID
Alias: 1560856
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)
3+29.1 EUR
Mindestbestellmenge: 3
FLUKE 1577
+4
FLUKE 1577 FLUKE 10923-eng.pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
1+1049.42 EUR
FLUKE 1587 FC
+3
FLUKE 1587 FC FLUKE Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf 15x7____umeng0200.pdf Fluke 1587 FC Manual (EN).pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: Bluetooth
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Anzahl je Verpackung: 1 Stücke
auf Bestellung 20 Stücke:
Lieferzeit 7-14 Tag (e)
1+1297.15 EUR
FLUKE 1587MDT FC
+12
FLUKE 1587MDT FC FLUKE Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf Fluke 1587 FC Manual (EN).pdf Fluke 1587 FC Manual (DE).pdf Category: Multimeters - Sets
Description: Measuring kit: multimeters; POM-5906A,POM-5907A,POM-6041B
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type temperature probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
1+1745.86 EUR
FLUKE 1587T
+5
FLUKE 1587T FLUKE 15x7____umeng0200.pdf 15x7____umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
1+1206.02 EUR
FLUKE 1630-2 FC
+2
FLUKE 1630-2 FC FLUKE 1630-2-FC.pdf FLK-1630-2-INS.pdf Fluke 1630-2 FC Manual EN.pdf Fluke 1630-2 FC Manual DE.pdf Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
1+2380.92 EUR
FLUKE 1662
+4
FLUKE 1662 FLUKE Fluke 1660 Series Datasheet EN.pdf Fluke 1660 Series Datasheet DE.pdf FLK-1662-SCH-INS.pdf Fluke 1660 Series Manual EN.pdf Fluke 1660 Series Manual DE.pdf Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; RCD test: general purpose; FLK-1660
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546944
Illumination: yes
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Insulation resistance measuring ranges: 0.01...100MΩ; 200MΩ; 500MΩ; 1000MΩ
Test voltage: 100V; 250V; 500V; 1kV
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)
1+1466.97 EUR
FLUKE 1662 UK FLUKE 1662 UK FLUKE 2612921.pdf Description: FLUKE - FLUKE 1662 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1663 FLUKE 1663 FLUKE Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 100mΩ÷200Ω,2kΩ
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; earthing resistance; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546980
Illumination: yes
Insulation resistance measuring ranges: 0.01...50MΩ; 100MΩ; 200MΩ; 500MΩ; 1000MΩ
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Test voltage: 50V; 100V; 250V; 500V; 1kV
Earthing resistance measuring range: 100mΩ...200Ω; 2kΩ
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
1+2002.37 EUR
FLUKE 1663 UK FLUKE 1663 UK FLUKE 2612921.pdf Description: FLUKE - FLUKE 1663 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664 FC EU FLUKE 1664 FC EU FLUKE 2612921.pdf Description: FLUKE - FLUKE 1664 FC EU - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664 FC UK FLUKE 1664 FC UK FLUKE 2612921.pdf Description: FLUKE - FLUKE 1664 FC UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664FC FLUKE FLK-1664FC-SCH Multimeters for Electrical Installations
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)
1+2606.46 EUR
FLUKE 166X MTC SCH FLUKE 166X MTC SCH FLUKE 2052842.pdf Description: FLUKE - FLUKE 166X MTC SCH - Konfektionierte Messleitung, Netzmessleitung Fluke 166X, SCHUKO (EU)
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Zur Verwendung mit: -
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 166X MTC UK FLUKE 166X MTC UK FLUKE 2052842.pdf Description: FLUKE - FLUKE 166X MTC UK - Konfektioniertes Prüfkabel, Netzkabel, Multifunktionstester der Baureihe 1660 von Fluke
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 175
+4
FLUKE 175 FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 48 Stücke:
Lieferzeit 7-14 Tag (e)
1+432.43 EUR
FLUKE 177
+5
FLUKE 177 FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 29 Stücke:
Lieferzeit 7-14 Tag (e)
1+523.38 EUR
FLUKE 179
+4
FLUKE 179 FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)
1+641.21 EUR
FLUKE 179 MAG KIT
+8
FLUKE 179 MAG KIT FLUKE 175_____umeng0100.pdf 175_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 37 Stücke:
Lieferzeit 7-14 Tag (e)
1+593.34 EUR
FLUKE 179/EDA2/EUR
+9
FLUKE 179/EDA2/EUR FLUKE Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf 175_____umeng0100.pdf Fluke 175 177 179 Manual DE.pdf 175_____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
1+685.13 EUR
FLUKE 179/TL-223 FLUKE Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads; FLK-TL-223 set
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
1+706.06 EUR
FLUKE 1AC II FLUKE 1AC II FLUKE 3215787.pdf Description: FLUKE - FLUKE 1AC II - Spannungsprüfer, berührungslos, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 34 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1AC-2-5PK FLUKE 1AC-2-5PK FLUKE Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage; set of 5 detectors
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)
1+192.15 EUR
FLUKE 1AC-E1-II FLUKE 1AC-E1-II FLUKE 2014226.pdf Description: FLUKE - FLUKE 1AC-E1-II - Spannungsprüfer, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1AC-E2-II FLUKE 1AC-E2-II FLUKE 11077-eng.pdf Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 24 Stücke:
Lieferzeit 7-14 Tag (e)
2+49.58 EUR
Mindestbestellmenge: 2
FLUKE 2042T FLUKE 2042T FLUKE Category: Metals & cables detectors
Description: Transmitter; FLK-2042
Type of test accessories: transmitter
Related items: FLK-2042
Alias: 2435045
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
FLUKE 2052
+1
FLUKE 2052 FLUKE mpdf (1).pdf Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 2,5",LED; IP40
Kind of display used: LCD 2,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Receiver dimensions: 183x75x43mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
1+1848.13 EUR
FLUKE 2062 PRO FLUKE 2062 PRO FLUKE Fluke 2062EN.pdf Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 3,5",LED; IP40
Kind of display used: LCD 3,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Receiver dimensions: 277x112x65mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
1+2977.26 EUR
FLUKE 233
+7
FLUKE 233 FLUKE Fluke 233 Datasheet EN.pdf Fluke 233 Datasheet DE.pdf Fluke 233 Manual EN.pdf Fluke 233 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-TL175 test leads; FLK-TOOLPAK strap with magnet for suspending the meter; soft carrying case FLK-C35; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5900A/POM; POM-6172A; POM-7519A
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 93x193x53mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery LR6 AA 1,5V x5
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.25% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x5
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; radio connection indicator; wireless display (range up to 10m)
Type of meter: digital multimeter
Weight with battery: 604g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)
1+636.64 EUR
FLUKE 27-II
+5
FLUKE 27-II FLUKE FLK-27-2.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
1+1027.71 EUR
FLUKE 279 FC/IFLEX Fluke FLUKE 279 FC/IFLEX
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
1+2315.95 EUR
2+ 2204.59 EUR
FLUKE 279FC/IFLEX
+2
FLUKE 279FC/IFLEX FLUKE Fluke 279 FC Datasheet (EN).pdf Fluke 279 FC Datasheet (DE).pdf Fluke 279 FC Manual (EN).pdf Fluke 279 FC Manual (DE).pdf Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Refresh rate: 8Hz
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Plug variant: EU
Camera resolution: 80x60
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
1+1679.76 EUR
FLUKE 27II/EUR FLUKE 27II/EUR FLUKE 1780920.pdf Description: FLUKE - FLUKE 27II/EUR - Digitalmultimeter, IP67, Industrie, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 10A
Messwert Wechselstrom, max.: 10A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 50Mohm
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 28 II EX
+5
FLUKE 28 II EX FLUKE Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
1+2464.02 EUR
FLUKE 28-II
+7
FLUKE 28-II FLUKE Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf Fluke 28-II Manual EN.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual DE.pdf 2x_2____umger0100.pdf Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
1+1027.71 EUR
FLUKE 287
+5
FLUKE 287 FLUKE 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf Fluke 287 Datasheet EN.pdf Fluke 287 Datasheet DE.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 287 & 289 Manual EN.pdf 287_289_umeng0200.pdf 287_289_umger0200.pdf Fluke 287 & 289 Manual DE.pdf Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FLUKE 280
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)
1+1145.4 EUR
FLUKE 287/EUR FLUKE 287/EUR FLUKE 1864347.pdf Description: FLUKE - FLUKE 287/EUR - Logging-Multimeter für Elektronik, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 47 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 287/FVF/EUR
+9
FLUKE 287/FVF/EUR FLUKE FLK-287FVF-DTE.PDF 287_289_umeng0200.pdf 287_289_umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
1+1338.48 EUR
FLUKE 287/FVF/EUR FLUKE 287/FVF/EUR FLUKE 705042.pdf Description: FLUKE - FLUKE 287/FVF/EUR - Tragbares Digitalmultimeter, mit Forms-Software & Kabel, Echteffektiv / TRMS
tariffCode: 90303200
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 50000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 4.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 289
+8
FLUKE 289 FLUKE 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf 287_289_umeng0200.pdf 287_289_umger0200.pdf Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FOX
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: FLK-TL175 test leads; holder for probes
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)
1+1240.67 EUR
FLUKE 289/EUR FLUKE 289/EUR FLUKE 2875664.pdf Description: FLUKE - FLUKE 289/EUR - Multimeter, Industrie, Fluke 289, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: -
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 50 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 107
Hersteller: FLUKE
FLK-107 Portable digital multimeters
auf Bestellung 41 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+159.73 EUR
FLUKE 113 Fluke 113 Datasheet EN.pdf Fluke 113 Manual EN.pdf Fluke 113 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Type of meter: digital multimeter
Measurement: capacitance; DC voltage; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 1mV...6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Diode test: 1.2mA @2.7V
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 404g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 84x167x46mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 110
Anzahl je Verpackung: 1 Stücke
auf Bestellung 13 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+221.36 EUR
Fluke 114 Fluke 114 Datasheet EN.pdf Manual 114-115-117 (EN).pdf 114_____umeng0100.pdf 114_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC voltage; DC voltage; resistance
Dimensions (W x H x D): 84x167x46mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+290 EUR
FLUKE 115 Fluke 115 Datasheet (english).pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5543B; POM-6275; POM-6343
Manufacturer series: Fluke 110
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Anzahl je Verpackung: 1 Stücke
auf Bestellung 33 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+337.98 EUR
FLUKE 116 Fluke 116 Datasheet EN.PDF Fluke 116 Manual EN.pdf Fluke 116 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0,1% + 2 digits)
Weight with battery: 550g
Power supply: battery 6LR61 9V x1
Measuring instruments application: heating and air-conditioning technology
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Manufacturer series: Fluke 110
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 84x167x46mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 2583601
Continuity test: acoustic indication; <20Ω
Frequency measuring accuracy: ±(0,1% + 2 digits)
Capacitance measuring accuracy: ±(1,9% + 2 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
AC current measuring accuracy: ±(1,5% + 3 digits)
DC current measuring accuracy: ±(1% + 2 digits)
AC voltage measuring accuracy: ±(1% + 3 digits)
True effective value measurement: True RMS AC
DC voltage measuring accuracy: ±(0,5% + 2 digits)
Bargraph: 33 segm. 32x/s
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Pollution degree: 2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+410.41 EUR
FLUKE 116 1780942.pdf
FLUKE 116
Hersteller: FLUKE
Description: FLUKE - FLUKE 116 - Digitalmultimeter, HLK, Baureihe 110, 6000 Zählwerte, TRMS, auto/manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 600V
Messwert Wechselspannung, max.: 600V
Messwert Widerstand, max.: 40Mohm
Messwert Gleichstrom, max.: 600µA
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Widerstand, Temperatur
Produktpalette: 110 Series
productTraceability: No
Messwert Wechselstrom, max.: 600µA
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 116/323 Fluke 116 Datasheet EN.PDF Fluke 116 Manual EN.pdf 32x_____umeng0000.pdf Fluke 116 Manual DE.pdf 32x_____umger0000.pdf
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296029
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+606.59 EUR
FLUKE 117 Fluke 117 Datasheet EN.pdf Manual 114-115-117 (EN).pdf 114_____umeng0100.pdf 114_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+423.41 EUR
FLUKE 117
Hersteller: Fluke
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 46 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+510.89 EUR
2+ 485.99 EUR
3+ 461.75 EUR
5+ 432.46 EUR
10+ 404.65 EUR
20+ 378.21 EUR
FLUKE 117
Hersteller: Fluke
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 84 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+510.89 EUR
2+ 485.99 EUR
3+ 461.75 EUR
5+ 432.46 EUR
10+ 404.65 EUR
20+ 378.21 EUR
50+ 353.05 EUR
Fluke 117/323 Fluke 117 Datasheet EN.pdf 32x_____umeng0000.pdf 114_____umeng0100.pdf Manual 114-115-117 (EN).pdf 114_____umger0100.pdf 32x_____umger0000.pdf
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296034
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+590.28 EUR
FLUKE 117/PRV240 1965994.pdf?_ga=2.181579303.1803553545.1505114253-1957280463.1504590177
FLUKE 117/PRV240
Hersteller: FLUKE
Description: FLUKE - FLUKE 117/PRV240 - Digitalmultimeter, Kit, DMM FLUKE-117 & Prüfeinheit Fluke PRV240
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Fluke 123B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2800.96 EUR
Fluke 123B/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf FLK-123B-INS.pdf Fluke 120B Series Manual EN.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+3601.68 EUR
Fluke 124B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+3361.67 EUR
Fluke 125B Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+4014.22 EUR
Fluke 125B/S Fluke 120B Series Datasheet EN.pdf Fluke 120B Series Datasheet DE.pdf Fluke 120B Series Manual EN.pdf FLK-123B-INS.pdf Fluke 120B Series Manual DE.pdf
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+4691.5 EUR
FLUKE 1503 10947-eng.pdf Fluke 1507 & 1503 Datasheet EN.pdf 1507____umeng0000.pdf Fluke 1507 & 1503 Manual EN.pdf 1507____umger0000.pdf Fluke 1507 & 1503 Manual DE.pdf
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+656.37 EUR
FLUKE 1507 10947-eng.pdf Fluke 1507 & 1503 Datasheet EN.pdf 1507____umeng0000.pdf Fluke 1507 & 1503 Manual EN.pdf 1507____umger0000.pdf Fluke 1507 & 1503 Manual DE.pdf
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+817.67 EUR
FLUKE 1560856
FLUKE 1560856
Hersteller: FLUKE
Category: Accessories - Others
Description: Display; FLK-177EGFID
Type of test accessories: display
Related items: FLK-177EGFID
Alias: 1560856
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
3+29.1 EUR
Mindestbestellmenge: 3
FLUKE 1577 10923-eng.pdf 15x7____umeng0200.pdf 15x7____umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1049.42 EUR
FLUKE 1587 FC Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf 15x7____umeng0200.pdf Fluke 1587 FC Manual (EN).pdf 15x7____umger0200.pdf Fluke 1587 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: Bluetooth
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Anzahl je Verpackung: 1 Stücke
auf Bestellung 20 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1297.15 EUR
FLUKE 1587MDT FC Fluke 1587 FC Datasheet (EN).pdf Fluke 1587 FC Datasheet (DE).pdf Fluke 1587 FC Manual (EN).pdf Fluke 1587 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters; POM-5906A,POM-5907A,POM-6041B
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type temperature probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1745.86 EUR
FLUKE 1587T 15x7____umeng0200.pdf 15x7____umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1206.02 EUR
FLUKE 1630-2 FC 1630-2-FC.pdf FLK-1630-2-INS.pdf Fluke 1630-2 FC Manual EN.pdf Fluke 1630-2 FC Manual DE.pdf
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2380.92 EUR
FLUKE 1662 Fluke 1660 Series Datasheet EN.pdf Fluke 1660 Series Datasheet DE.pdf FLK-1662-SCH-INS.pdf Fluke 1660 Series Manual EN.pdf Fluke 1660 Series Manual DE.pdf
Hersteller: FLUKE
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; RCD test: general purpose; FLK-1660
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546944
Illumination: yes
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Insulation resistance measuring ranges: 0.01...100MΩ; 200MΩ; 500MΩ; 1000MΩ
Test voltage: 100V; 250V; 500V; 1kV
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1466.97 EUR
FLUKE 1662 UK 2612921.pdf
FLUKE 1662 UK
Hersteller: FLUKE
Description: FLUKE - FLUKE 1662 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1663
FLUKE 1663
Hersteller: FLUKE
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 100mΩ÷200Ω,2kΩ
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; earthing resistance; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546980
Illumination: yes
Insulation resistance measuring ranges: 0.01...50MΩ; 100MΩ; 200MΩ; 500MΩ; 1000MΩ
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Test voltage: 50V; 100V; 250V; 500V; 1kV
Earthing resistance measuring range: 100mΩ...200Ω; 2kΩ
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2002.37 EUR
FLUKE 1663 UK 2612921.pdf
FLUKE 1663 UK
Hersteller: FLUKE
Description: FLUKE - FLUKE 1663 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664 FC EU 2612921.pdf
FLUKE 1664 FC EU
Hersteller: FLUKE
Description: FLUKE - FLUKE 1664 FC EU - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664 FC UK 2612921.pdf
FLUKE 1664 FC UK
Hersteller: FLUKE
Description: FLUKE - FLUKE 1664 FC UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1664FC
Hersteller: FLUKE
FLK-1664FC-SCH Multimeters for Electrical Installations
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2606.46 EUR
FLUKE 166X MTC SCH 2052842.pdf
FLUKE 166X MTC SCH
Hersteller: FLUKE
Description: FLUKE - FLUKE 166X MTC SCH - Konfektionierte Messleitung, Netzmessleitung Fluke 166X, SCHUKO (EU)
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Zur Verwendung mit: -
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 166X MTC UK 2052842.pdf
FLUKE 166X MTC UK
Hersteller: FLUKE
Description: FLUKE - FLUKE 166X MTC UK - Konfektioniertes Prüfkabel, Netzkabel, Multifunktionstester der Baureihe 1660 von Fluke
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 175 Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 48 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+432.43 EUR
FLUKE 177 Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 29 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+523.38 EUR
FLUKE 179 Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf Fluke 175 177 179 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+641.21 EUR
FLUKE 179 MAG KIT 175_____umeng0100.pdf 175_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 37 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+593.34 EUR
FLUKE 179/EDA2/EUR Fluke 175 177 179 Datasheet EN.pdf Fluke 175 177 179 Manual EN.pdf 175_____umeng0100.pdf Fluke 175 177 179 Manual DE.pdf 175_____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+685.13 EUR
FLUKE 179/TL-223
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads; FLK-TL-223 set
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+706.06 EUR
FLUKE 1AC II 3215787.pdf
FLUKE 1AC II
Hersteller: FLUKE
Description: FLUKE - FLUKE 1AC II - Spannungsprüfer, berührungslos, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 34 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1AC-2-5PK
FLUKE 1AC-2-5PK
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage; set of 5 detectors
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+192.15 EUR
FLUKE 1AC-E1-II 2014226.pdf
FLUKE 1AC-E1-II
Hersteller: FLUKE
Description: FLUKE - FLUKE 1AC-E1-II - Spannungsprüfer, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 1AC-E2-II 11077-eng.pdf
FLUKE 1AC-E2-II
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 24 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
2+49.58 EUR
Mindestbestellmenge: 2
FLUKE 2042T
FLUKE 2042T
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Transmitter; FLK-2042
Type of test accessories: transmitter
Related items: FLK-2042
Alias: 2435045
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
FLUKE 2052 mpdf (1).pdf
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 2,5",LED; IP40
Kind of display used: LCD 2,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Receiver dimensions: 183x75x43mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1848.13 EUR
FLUKE 2062 PRO Fluke 2062EN.pdf
FLUKE 2062 PRO
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 3,5",LED; IP40
Kind of display used: LCD 3,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Receiver dimensions: 277x112x65mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2977.26 EUR
FLUKE 233 Fluke 233 Datasheet EN.pdf Fluke 233 Datasheet DE.pdf Fluke 233 Manual EN.pdf Fluke 233 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-TL175 test leads; FLK-TOOLPAK strap with magnet for suspending the meter; soft carrying case FLK-C35; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5900A/POM; POM-6172A; POM-7519A
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 93x193x53mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery LR6 AA 1,5V x5
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.25% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x5
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; radio connection indicator; wireless display (range up to 10m)
Type of meter: digital multimeter
Weight with battery: 604g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+636.64 EUR
FLUKE 27-II FLK-27-2.pdf 2x_2____umeng0100.pdf 2x_2____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1027.71 EUR
FLUKE 279 FC/IFLEX
Hersteller: Fluke
FLUKE 279 FC/IFLEX
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl Preis ohne MwSt
1+2315.95 EUR
2+ 2204.59 EUR
FLUKE 279FC/IFLEX Fluke 279 FC Datasheet (EN).pdf Fluke 279 FC Datasheet (DE).pdf Fluke 279 FC Manual (EN).pdf Fluke 279 FC Manual (DE).pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Refresh rate: 8Hz
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Plug variant: EU
Camera resolution: 80x60
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1679.76 EUR
FLUKE 27II/EUR 1780920.pdf
FLUKE 27II/EUR
Hersteller: FLUKE
Description: FLUKE - FLUKE 27II/EUR - Digitalmultimeter, IP67, Industrie, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 10A
Messwert Wechselstrom, max.: 10A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 50Mohm
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 28 II EX Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual EN.pdf 2x_2____umger0100.pdf Fluke 28-II Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+2464.02 EUR
FLUKE 28-II Fluke 28-II Datasheet EN.pdf Fluke 28-II Datasheet DE.pdf Fluke 28-II Manual EN.pdf 2x_2____umeng0100.pdf Fluke 28-II Manual DE.pdf 2x_2____umger0100.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1027.71 EUR
FLUKE 287 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf Fluke 287 Datasheet EN.pdf Fluke 287 Datasheet DE.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf Fluke 287 & 289 Manual EN.pdf 287_289_umeng0200.pdf 287_289_umger0200.pdf Fluke 287 & 289 Manual DE.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FLUKE 280
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1145.4 EUR
FLUKE 287/EUR 1864347.pdf
FLUKE 287/EUR
Hersteller: FLUKE
Description: FLUKE - FLUKE 287/EUR - Logging-Multimeter für Elektronik, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 47 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 287/FVF/EUR FLK-287FVF-DTE.PDF 287_289_umeng0200.pdf 287_289_umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1338.48 EUR
FLUKE 287/FVF/EUR 705042.pdf
FLUKE 287/FVF/EUR
Hersteller: FLUKE
Description: FLUKE - FLUKE 287/FVF/EUR - Tragbares Digitalmultimeter, mit Forms-Software & Kabel, Echteffektiv / TRMS
tariffCode: 90303200
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 50000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 4.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)
FLUKE 289 6001874B-EN-FC-Reasons-Why-Flyer-w.pdf 6001874B-de-FC-Reasons-Why-Flyer-w.pdf 287_289_umeng0200.pdf 287_289_umger0200.pdf
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FOX
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: FLK-TL175 test leads; holder for probes
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl Preis ohne MwSt
1+1240.67 EUR
FLUKE 289/EUR 2875664.pdf
FLUKE 289/EUR
Hersteller: FLUKE
Description: FLUKE - FLUKE 289/EUR - Multimeter, Industrie, Fluke 289, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: -
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 50 Stücke:
Lieferzeit 14-21 Tag (e)
Wählen Sie Seite:   1 2  Nächste Seite >> ]