Suchergebnisse für "FLUKE" : > 60
Wählen Sie Seite:
1
2
[ Nächste Seite >> ]
Art der Ansicht :
Mindestbestellmenge: 3
Mindestbestellmenge: 2
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis ohne MwSt |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLUKE 107 | FLUKE | FLK-107 Portable digital multimeters |
auf Bestellung 41 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
+5 |
FLUKE 113 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V Type of meter: digital multimeter Measurement: capacitance; DC voltage; resistance Kind of display used: LCD Display parameters: 3,75 digit (6000) DC voltage measuring range: 1mV...6V; 60V; 600V DC voltage measuring accuracy: ±(0.5% + 2 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1.9%+ 2 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Diode test: 1.2mA @2.7V Continuity test: acoustic indication; <20Ω Pollution degree: 2 Weight with battery: 404g Power supply: battery 6LR61 9V x1 Standard equipment: FLK-TL75 test leads Conform to the norm: CAT III 600V; EN 61010 Dimensions (W x H x D): 84x167x46mm Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Battery/ rechargeable battery: battery 6LR61 9V x1 Manufacturer series: Fluke 110 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 13 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
Fluke 114 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 600V; EN 61010 Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222 Pollution degree: 2 Related items: POM-5673B; POM-5900A/POM; POM-7519A Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC voltage; DC voltage; resistance Dimensions (W x H x D): 84x167x46mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) DC voltage measuring accuracy: ±(0.5% + 2 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Continuity test: acoustic indication; <20Ω Anzahl je Verpackung: 1 Stücke |
auf Bestellung 12 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+4 |
FLUKE 115 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 600V; EN 61010 Related items: POM-5543B; POM-6275; POM-6343 Manufacturer series: Fluke 110 Standard equipment: FLK-TL75 test leads Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Continuity test: acoustic indication; <20Ω Pollution degree: 2 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 84x167x46mm AC current measuring range: 1mA...6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Diode test: 1.2mA @2.7V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 33 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 116 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA Type of meter: digital multimeter Kind of display used: LCD Display parameters: 3,75 digit (6000) Temperature measuring range: -40...400°C Temperature measurement accuracy: ±(0,1% + 2 digits) Weight with battery: 550g Power supply: battery 6LR61 9V x1 Measuring instruments application: heating and air-conditioning technology Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature Manufacturer series: Fluke 110 Conform to the norm: CAT III 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Dimensions (W x H x D): 84x167x46mm Battery/ rechargeable battery: battery 6LR61 9V x1 Alias: 2583601 Continuity test: acoustic indication; <20Ω Frequency measuring accuracy: ±(0,1% + 2 digits) Capacitance measuring accuracy: ±(1,9% + 2 digits) Resistance measuring accuracy: ±(0,9% + 1 digit) AC current measuring accuracy: ±(1,5% + 3 digits) DC current measuring accuracy: ±(1% + 2 digits) AC voltage measuring accuracy: ±(1% + 3 digits) True effective value measurement: True RMS AC DC voltage measuring accuracy: ±(0,5% + 2 digits) Bargraph: 33 segm. 32x/s AC current measuring range: 0.1...600µA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 0.1...600µA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Pollution degree: 2 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 7 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 116 | FLUKE |
Description: FLUKE - FLUKE 116 - Digitalmultimeter, HLK, Baureihe 110, 6000 Zählwerte, TRMS, auto/manuelle Bereichswahl, 3.5-stellig tariffCode: 90303100 Messwert Gleichspannung, max.: 600V Messwert Wechselspannung, max.: 600V Messwert Widerstand, max.: 40Mohm Messwert Gleichstrom, max.: 600µA rohsCompliant: Y-EX hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a euEccn: NLR DMM-Funktionen: Strom, Spannung, Kapazität, Widerstand, Temperatur Produktpalette: 110 Series productTraceability: No Messwert Wechselstrom, max.: 600µA |
auf Bestellung 16 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+10 |
FLUKE 116/323 | FLUKE |
Category: Multimeters - Sets Description: Measuring kit: multimeters Type of measuring kit: multimeters Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 Alias: 4296029 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 117 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 600V; EN 61010 Standard equipment: FLK-TL75 test leads Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222 Pollution degree: 2 Related items: POM-5673B; POM-5900A/POM; POM-7519A Manufacturer series: Fluke 110 True effective value measurement: True RMS AC Bargraph: 33 segm. 32x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Dimensions (W x H x D): 84x167x46mm AC current measuring range: 1mA...6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.5% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 2 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster Type of meter: digital multimeter Weight with battery: 550g Continuity test: acoustic indication; <20Ω Anzahl je Verpackung: 1 Stücke |
auf Bestellung 46 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 117 | Fluke | ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE |
auf Bestellung 46 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||||||||||||
FLUKE 117 | Fluke | ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE |
auf Bestellung 84 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||||||||||||
+7 |
Fluke 117/323 | FLUKE |
Category: Multimeters - Sets Description: Measuring kit: multimeters Type of measuring kit: multimeters Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2 Alias: 4296034 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 12 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 117/PRV240 | FLUKE |
Description: FLUKE - FLUKE 117/PRV240 - Digitalmultimeter, Kit, DMM FLUKE-117 & Prüfeinheit Fluke PRV240 tariffCode: 90303100 productTraceability: No rohsCompliant: Y-EX euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: Multicomp Pro RJ45 Adapter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+3 |
Fluke 123B | FLUKE |
Category: Portable Oscilloscopes, Scopemeters Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Manufacturer series: FLUKE 120B Number of channels: 2 Display resolution: 640x480 Additional functions: multimeter Band: 20MHz Dimensions: 259x132x55mm Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Plug variant: EU Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance IP rating: IP51 Time base: 20n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Resistance measuring accuracy: ±(0.6%+5 digit) DC voltage measuring accuracy: ±(0.5% + 5 digit) Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+15 |
Fluke 123B/S | FLUKE |
Category: Portable Oscilloscopes, Scopemeters Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Manufacturer series: FLUKE 120B Number of channels: 2 Display resolution: 640x480 Additional functions: multimeter Band: 20MHz Software: Fluke View Dimensions: 259x132x55mm Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Plug variant: EU Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance IP rating: IP51 Time base: 20n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector Resistance measuring accuracy: ±(0.6%+5 digit) DC voltage measuring accuracy: ±(0.5% + 5 digit) Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+16 |
Fluke 124B | FLUKE |
Category: Portable Oscilloscopes, Scopemeters Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Manufacturer series: FLUKE 120B Number of channels: 2 Display resolution: 640x480 Additional functions: multimeter Band: 40MHz Dimensions: 259x132x55mm Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Plug variant: EU Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance IP rating: IP51 Time base: 10n...60s/div Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter Resistance measuring accuracy: ±(0.6%+5 digit) DC voltage measuring accuracy: ±(0.5% + 5 digit) Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp Anzahl je Verpackung: 1 Stücke |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
Fluke 125B | FLUKE |
Category: Portable Oscilloscopes, Scopemeters Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Related items: POM-72941; POM-72942 Kind of display used: colour; LCD TFT 5,7" Manufacturer series: FLUKE 120B Number of channels: 2 Display resolution: 640x480 Additional functions: multimeter Band: 40MHz Dimensions: 259x132x55mm Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Plug variant: EU Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance IP rating: IP51 Time base: 10n...60s/div Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp Resistance measuring accuracy: ±(0.6%+5 digit) DC voltage measuring accuracy: ±(0.5% + 5 digit) Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+16 |
Fluke 125B/S | FLUKE |
Category: Portable Oscilloscopes, Scopemeters Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div Kind of display used: colour; LCD TFT 5,7" Manufacturer series: FLUKE 120B Number of channels: 2 Display resolution: 640x480 Additional functions: multimeter Band: 40MHz Software: Fluke View Dimensions: 259x132x55mm Continuity test: acoustic indication Sampling: 40Msps Type of oscilloscope: scopemeter Plug variant: EU Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010 Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance IP rating: IP51 Time base: 10n...60s/div Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF Diode test: 0.5mA @2.8V Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1 Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1 Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector Resistance measuring accuracy: ±(0.6%+5 digit) DC voltage measuring accuracy: ±(0.5% + 5 digit) Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+1 |
FLUKE 1503 | FLUKE |
Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Conform to the norm: CAT IV 600V; EN 61010 Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter IP rating: IP40 Related items: POM-5674C; POM-5907A; POM-6041B Automatic discharging capacitance: max. 1µF Open circuit test voltage: 4...8V Measurement: AC voltage; DC voltage; insulation resistance; resistance Bandwidth for AC voltage measurements: 50...400Hz Test voltage: 500V DC; 1kV DC Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.5%+3 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Body dimensions: 203x100x50mm Illumination: yes Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe Type of meter: insulation resistance Weight with battery: 550g Continuity test: acoustic indication Capacitance discharge time: <0.5s Anzahl je Verpackung: 1 Stücke |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+1 |
FLUKE 1507 | FLUKE |
Category: Insulation Resistance Meters Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40 Conform to the norm: CAT IV 600V; EN 61010 Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter IP rating: IP40 Related items: POM-5674C; POM-5907A; POM-6041B Automatic discharging capacitance: max. 1µF Open circuit test voltage: 4...8V Measurement: AC voltage; DC voltage; insulation resistance; resistance Bandwidth for AC voltage measurements: 50...400Hz Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ DC voltage measuring accuracy: ±(2% + 3 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.5%+3 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Body dimensions: 203x100x50mm Illumination: yes Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection Type of meter: insulation resistance Weight with battery: 550g Continuity test: acoustic indication Capacitance discharge time: <0.5s Anzahl je Verpackung: 1 Stücke |
auf Bestellung 6 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 1560856 | FLUKE |
Category: Accessories - Others Description: Display; FLK-177EGFID Type of test accessories: display Related items: FLK-177EGFID Alias: 1560856 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 9 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
+4 |
FLUKE 1577 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Type of meter: digital multimeter Weight with battery: 550g Optional equipment: FLK-C25 soft cover Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance Dimensions (W x H x D): 100x203x50mm Test voltage: 500V; 1kV AC current measuring range: 10µA...60mA; 400mA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) AC current measuring accuracy: ±(2% + 2 digit) DC voltage measuring accuracy: ±(0.2% + 2 digit) DC current measuring accuracy: ±(1% + 2 digit) AC voltage measuring accuracy: ±(2% + 3 digit) Resistance measuring accuracy: ±(1.2%+2 digit) Insulation resistance measuring accuracy: ±(2% + 5digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 IP rating: IP40 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+3 |
FLUKE 1587 FC | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Optional equipment: FLK-C25 soft cover IP rating: IP40 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B Temperature measuring range: -40...537°C True effective value measurement: True RMS AC Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature Dimensions (W x H x D): 100x203x50mm Test voltage: 500V AC current measuring range: 10µA...60mA; 400mA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @6V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Insulation resistance measuring accuracy: ±(1.5% + 5digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 Interface: Bluetooth Illumination: yes Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test Type of meter: digital multimeter Weight with battery: 550g Continuity test: acoustic indication; <25Ω Temperature measurement resolution: 0.1°C Anzahl je Verpackung: 1 Stücke |
auf Bestellung 20 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+12 |
FLUKE 1587MDT FC | FLUKE |
Category: Multimeters - Sets Description: Measuring kit: multimeters; POM-5906A,POM-5907A,POM-6041B Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type temperature probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual Related items: POM-5906A; POM-5907A; POM-6041B Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Type of measuring kit: multimeters Anzahl je Verpackung: 1 Stücke |
auf Bestellung 4 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 1587T | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function Type of meter: digital multimeter Optional equipment: FLK-C25 soft cover Continuity test: acoustic indication; <25Ω Temperature measurement resolution: 0.1°C Temperature measuring range: -40...537°C True effective value measurement: True RMS Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature Dimensions (W x H x D): 100x203x50mm Test voltage: 50V; 100V AC current measuring range: 10µA...60mA; 400mA Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1mA @6V Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Insulation resistance measuring ranges: 10kΩ...100MΩ Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 2 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(0.2% + 2 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+2 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x4 IP rating: IP40 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Illumination: yes Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+2 |
FLUKE 1630-2 FC | FLUKE |
Category: Clamp Meters - Others Description: Meter: grounding resistance; pincers type; LCD; (9999) Type of meter: grounding resistance Kind of meter: pincers type Kind of display used: LCD Display parameters: (9999) Measurement: leakage current; resistance Interface: Bluetooth Battery/ rechargeable battery: battery 6LR61 9V x1 Alias: 4829532 Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ Resistance measuring accuracy: ±(1,5% + 3 digits) Continuity test: acoustic indication Anzahl je Verpackung: 1 Stücke |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+4 |
FLUKE 1662 | FLUKE |
Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; RCD test: general purpose; FLK-1660 Type of meter: appliance meter Kind of display used: LCD Measurement: AC voltage; frequency; insulation resistance; RCD tripping current; RCD tripping time AC voltage measuring range: 100mV...500V AC voltage measuring accuracy: ±(0,8% + 3 digits) Power supply: battery LR6 AA 1,5V x6 Plug variant: EU Measuring instrument features: checks conductors polarization Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual Body dimensions: 100x250x125mm Manufacturer series: FLK-1660 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 RCD test: general purpose Alias: 4546944 Illumination: yes Earthing resistance measuring accuracy: ±(2% + 5 digits) Insulation resistance measuring ranges: 0.01...100MΩ; 200MΩ; 500MΩ; 1000MΩ Test voltage: 100V; 250V; 500V; 1kV Anzahl je Verpackung: 1 Stücke |
auf Bestellung 9 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 1662 UK | FLUKE |
Description: FLUKE - FLUKE 1662 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm tariffCode: 90303370 productTraceability: No Isolationswiderstand, max.: 1000Mohm rohsCompliant: Y-EX Messwert Gleichspannung, max.: 500V Messwert Wechselspannung, max.: 500V Isolationswiderstand, min.: 20Mohm euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: 1660 Series SVHC: No SVHC (20-Jun-2016) |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1663 | FLUKE |
Category: Multimeters for Electrical Installations Description: Meter: appliance meter; LCD; Earthing R range: 100mΩ÷200Ω,2kΩ Type of meter: appliance meter Kind of display used: LCD Measurement: AC voltage; earthing resistance; frequency; insulation resistance; RCD tripping current; RCD tripping time AC voltage measuring range: 100mV...500V AC voltage measuring accuracy: ±(0,8% + 3 digits) Power supply: battery LR6 AA 1,5V x6 Plug variant: EU Measuring instrument features: checks conductors polarization Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual Body dimensions: 100x250x125mm Manufacturer series: FLK-1660 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 RCD test: general purpose Alias: 4546980 Illumination: yes Insulation resistance measuring ranges: 0.01...50MΩ; 100MΩ; 200MΩ; 500MΩ; 1000MΩ Earthing resistance measuring accuracy: ±(2% + 5 digits) Test voltage: 50V; 100V; 250V; 500V; 1kV Earthing resistance measuring range: 100mΩ...200Ω; 2kΩ |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
FLUKE 1663 UK | FLUKE |
Description: FLUKE - FLUKE 1663 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm tariffCode: 90303370 productTraceability: No Isolationswiderstand, max.: 1000Mohm rohsCompliant: TBA Messwert Gleichspannung, max.: 500V Messwert Wechselspannung, max.: 500V Isolationswiderstand, min.: 20Mohm euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: 1660 Series |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1664 FC EU | FLUKE |
Description: FLUKE - FLUKE 1664 FC EU - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm tariffCode: 90303370 productTraceability: No Isolationswiderstand, max.: 1000Mohm rohsCompliant: TBA Messwert Gleichspannung, max.: 500V Messwert Wechselspannung, max.: 500V Isolationswiderstand, min.: 20Mohm euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: 1660 FC Series |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1664 FC UK | FLUKE |
Description: FLUKE - FLUKE 1664 FC UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm tariffCode: 90303370 productTraceability: No Isolationswiderstand, max.: 1000Mohm rohsCompliant: Y-EX Messwert Gleichspannung, max.: 500V Messwert Wechselspannung, max.: 500V Isolationswiderstand, min.: 20Mohm euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: 1660 FC Series SVHC: No SVHC (20-Jun-2016) |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1664FC | FLUKE | FLK-1664FC-SCH Multimeters for Electrical Installations |
auf Bestellung 8 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
FLUKE 166X MTC SCH | FLUKE |
Description: FLUKE - FLUKE 166X MTC SCH - Konfektionierte Messleitung, Netzmessleitung Fluke 166X, SCHUKO (EU) tariffCode: 85444290 productTraceability: No rohsCompliant: YES euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA Zur Verwendung mit: - usEccn: EAR99 Produktpalette: 1660 Series |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 166X MTC UK | FLUKE |
Description: FLUKE - FLUKE 166X MTC UK - Konfektioniertes Prüfkabel, Netzkabel, Multifunktionstester der Baureihe 1660 von Fluke tariffCode: 85444290 productTraceability: No rohsCompliant: YES euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: EAR99 Produktpalette: 1660 Series |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+4 |
FLUKE 175 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.15% + 2 digit) AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Manufacturer series: Fluke 170 Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Standard equipment: FLK-TL75 test leads Battery/ rechargeable battery: battery 6LR61 9V x1 Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Kind of display used: LCD Type of meter: digital multimeter Weight with battery: 420g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Dimensions (W x H x D): 89x190x45mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC current measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Anzahl je Verpackung: 1 Stücke |
auf Bestellung 48 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 177 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.09% + 2 digit) AC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC current measuring range: 10µA...60mA; 400mA; 6A; 10A Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance Manufacturer series: Fluke 170 Power supply: battery 6LR61 9V x1 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Standard equipment: FLK-TL75 test leads Battery/ rechargeable battery: battery 6LR61 9V x1 Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Kind of display used: LCD Type of meter: digital multimeter Weight with battery: 420g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Continuity test: acoustic indication; <25Ω True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Dimensions (W x H x D): 89x190x45mm Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC current measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Anzahl je Verpackung: 1 Stücke |
auf Bestellung 29 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+4 |
FLUKE 179 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Manufacturer series: Fluke 170 Temperature measuring range: -40...400°C True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 89x190x45mm AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Weight with battery: 420g Continuity test: acoustic indication; <25Ω Anzahl je Verpackung: 1 Stücke |
auf Bestellung 46 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+8 |
FLUKE 179 MAG KIT | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4 Related items: POM-5904A/POM; POM-6343; POM-7519A Battery/ rechargeable battery: battery 6F22 9V x1 Type of meter: digital multimeter Anzahl je Verpackung: 1 Stücke |
auf Bestellung 37 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+9 |
FLUKE 179/EDA2/EUR | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip Related items: POM-5904A/POM; POM-6343; POM-7519A Battery/ rechargeable battery: battery 6LR61 9V x1 Type of meter: digital multimeter Anzahl je Verpackung: 1 Stücke |
auf Bestellung 12 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 179/TL-223 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads; FLK-TL-223 set Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A Manufacturer series: Fluke 170 Temperature measuring range: -40...400°C True effective value measurement: True RMS AC Bargraph: 33 segm. 40x/s Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 89x190x45mm AC current measuring range: 10µA...60mA; 400mA; 6A; 10A Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ DC current measuring range: 10µA...60mA; 400mA; 6A; 10A DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.1mA @2.4V Battery/ rechargeable battery: battery 6LR61 9V x1 Display parameters: 3,75 digit (6000) Frequency measuring accuracy: ±(0.1%+1 digit) Capacitance measuring accuracy: ±(1.2%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.09% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD Power supply: battery 6LR61 9V x1 Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals Type of meter: digital multimeter Weight with battery: 420g Continuity test: acoustic indication; <25Ω Anzahl je Verpackung: 1 Stücke |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
FLUKE 1AC II | FLUKE |
Description: FLUKE - FLUKE 1AC II - Spannungsprüfer, berührungslos, 200V bis 1kV, LED, -10 °C, 50 °C tariffCode: 90303370 productTraceability: No rohsCompliant: Y-EX euEccn: NLR Netzsteckertyp: - hazardous: false rohsPhthalatesCompliant: TBA Betriebstemperatur, min.: -10°C Betriebstemperatur, max.: 50°C usEccn: 3A992 Produktpalette: Multicomp Pro RJ45 Adapter |
auf Bestellung 34 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1AC-2-5PK | FLUKE |
Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 200...1000V AC IP rating: IP40 Conform to the norm: CAT IV 1000V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage; set of 5 detectors Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 18 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
FLUKE 1AC-E1-II | FLUKE |
Description: FLUKE - FLUKE 1AC-E1-II - Spannungsprüfer, 200V bis 1kV, LED, -10 °C, 50 °C tariffCode: 90303370 productTraceability: No rohsCompliant: Y-EX euEccn: NLR Netzsteckertyp: - hazardous: false rohsPhthalatesCompliant: TBA Betriebstemperatur, min.: -10°C Betriebstemperatur, max.: 50°C usEccn: 3A992.a Produktpalette: Multicomp Pro RJ45 Adapter |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
FLUKE 1AC-E2-II | FLUKE |
Category: Indicators, Voltage & Continuity Testers Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40 Type of tester: non-contact voltage detector Detected voltage range: 200...1000V AC IP rating: IP40 Conform to the norm: CAT IV 1000V; EN 61010 Power supply: battery LR03 AAA 1,5V x2 Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 24 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
FLUKE 2042T | FLUKE |
Category: Metals & cables detectors Description: Transmitter; FLK-2042 Type of test accessories: transmitter Related items: FLK-2042 Alias: 2435045 Anzahl je Verpackung: 1 Stücke |
Produkt ist nicht verfügbar |
||||||||||||||||
+1 |
FLUKE 2052 | FLUKE |
Category: Metals & cables detectors Description: Non-contact metal and voltage detector; LCD 2,5",LED; IP40 Kind of display used: LCD 2,5"; LED Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter Power supply: rechargeable battery Ni-MH AA 1,2V x12 Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12 Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires Receiver dimensions: 183x75x43mm Transmitter dimensions: 183x93x50mm Type of tester: non-contact metal and voltage detector Conform to the norm: CAT IV 600V; EN 61010 Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air) Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz Detected voltage range: 0...600V AC; 0...600V DC IP rating: IP40 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 2062 PRO | FLUKE |
Category: Metals & cables detectors Description: Non-contact metal and voltage detector; LCD 3,5",LED; IP40 Kind of display used: LCD 3,5"; LED Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter Power supply: rechargeable battery Ni-MH AA 1,2V x12 Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12 Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires Receiver dimensions: 277x112x65mm Transmitter dimensions: 183x93x50mm Type of tester: non-contact metal and voltage detector Conform to the norm: CAT IV 600V; EN 61010 Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air) Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz Detected voltage range: 0...600V AC; 0...600V DC IP rating: IP40 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 3 Stücke: Lieferzeit 7-14 Tag (e) |
|
|||||||||||||||
+7 |
FLUKE 233 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; test leads Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-TL175 test leads; FLK-TOOLPAK strap with magnet for suspending the meter; soft carrying case FLK-C35; test leads FLK-TL71; test leads FLK-TL224 SureGrip Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5900A/POM; POM-6172A; POM-7519A Temperature measuring range: -40...400°C True effective value measurement: True RMS AC Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Dimensions (W x H x D): 93x193x53mm AC current measuring range: 1mA...6A; 10A; (20A <30s) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ DC current measuring range: 1mA...6A; 10A; 20A < 30s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF Diode test: 1.2mA @2.7V Battery/ rechargeable battery: battery LR6 AA 1,5V x5 Display parameters: (6000) Frequency measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(1.9%+ 2 digit) AC current measuring accuracy: ±(1.5% + 3 digit) DC voltage measuring accuracy: ±(0.25% + 2 digit) DC current measuring accuracy: ±(1% + 3 digit) AC voltage measuring accuracy: ±(1% + 3 digit) Resistance measuring accuracy: ±(0.9%+1 digit) Temperature measurement accuracy: ±(1% + 10 digit) Kind of display used: LCD Power supply: battery LR6 AA 1,5V x5 Illumination: yes Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; radio connection indicator; wireless display (range up to 10m) Type of meter: digital multimeter Weight with battery: 604g Continuity test: acoustic indication; <20Ω Anzahl je Verpackung: 1 Stücke |
auf Bestellung 7 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 27-II | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67 Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 33 segm. 40x/s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(2% + 3 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1.5% + 2 digit) Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Duty cycle factor: 0...99.9% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Diode test: 1mA @2.8V Continuity test: acoustic indication IP rating: IP67 Weight with battery: 517g Power supply: battery LR6 AA 1,5V x3 Standard equipment: test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Dimensions (W x H x D): 100x198x63.5mm Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Illumination: yes Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 279 FC/IFLEX | Fluke | FLUKE 279 FC/IFLEX |
auf Bestellung 2 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||||||||||||
+2 |
FLUKE 279FC/IFLEX | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A Interface: Bluetooth Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance Refresh rate: 8Hz Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads Type of meter: digital multimeter with infrared camera Continuity test: acoustic indication; <25Ω Non-contact temperature measuring range: -10...200°C Emissivity value: 0,95 (fixed) Focusing: focus free Plug variant: EU Camera resolution: 80x60 Dimensions (W x H x D): 93.9x215.9x57.1mm Thermal sensitivity (NETD): ≤0.2°C AC current measuring range: 100mA...999.9A; 2.5kA Resistance measuring range: 600Ω...50MΩ DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV Frequency measuring range: 99.99...999.9Hz Capacitance measuring range: 1000nF...9999µF Diode test: 2V Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1 Connectors for the country: Great Britain Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 5 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 27II/EUR | FLUKE |
Description: FLUKE - FLUKE 27II/EUR - Digitalmultimeter, IP67, Industrie, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.5-stellig tariffCode: 90303100 Messwert Gleichstrom, max.: 10A Messwert Wechselstrom, max.: 10A productTraceability: No rohsCompliant: Y-EX Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA Messwert Widerstand, max.: 50Mohm usEccn: 3A992.a Produktpalette: Multicomp Pro RJ45 Adapter |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+5 |
FLUKE 28 II EX | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Kind of display used: LCD Display parameters: (6000/19999) Bargraph: 33 segm. 40x/s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1% + 2 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Duty cycle factor: 0...99.9% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Diode test: 1mA @2.8V Continuity test: acoustic indication IP rating: IP67 Weight with battery: 517g Power supply: battery LR03 AAA 1,5V x3 Standard equipment: test leads Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Dimensions (W x H x D): 100x198x63.5mm Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Battery/ rechargeable battery: battery LR03 AAA 1,5V x3 Illumination: yes Anzahl je Verpackung: 1 Stücke |
auf Bestellung 2 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+7 |
FLUKE 28-II | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature Kind of display used: LCD Display parameters: (6000) Bargraph: 33 segm. 40x/s DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(1% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A DC current measuring accuracy: ±(0.2% + 2 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A AC current measuring accuracy: ±(1% + 2 digit) True effective value measurement: True RMS Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.2%+1 digit) Temperature measurement resolution: 0.1°C Conductance measurement: 0.01...60nS Duty cycle factor: 0...99.9% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Diode test: 1mA @2.8V Continuity test: acoustic indication IP rating: IP67 Weight with battery: 517g Power supply: battery LR6 AA 1,5V x3 Standard equipment: test leads Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA Dimensions (W x H x D): 100x198x63.5mm Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Illumination: yes Anzahl je Verpackung: 1 Stücke |
auf Bestellung 4 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
+5 |
FLUKE 287 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54 Kind of display used: colour; LCD TFT 2,2" Display parameters: (50000) Manufacturer series: FLUKE 280 Display resolution: 320x240 Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Fluke Connect (FLK-IR3000FC) Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz IP rating: IP54 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Temperature measuring range: -200...1350°C True effective value measurement: True RMS AC; True RMS AC+DC Bargraph: 51 segm. Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Dimensions (W x H x D): 102x222x60mm AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF Diode test: 1mA @3.1V Frequency measuring accuracy: ±(0.005%+5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) AC current measuring accuracy: ±(0.6% + 5 digit) DC voltage measuring accuracy: ±(0.025% + 2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.05%+2 digit) Temperature measurement accuracy: ±(1% + 1°C) Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measurement memory: 10k Standard equipment: holder for probes; test leads FLK-TL71 Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function Type of meter: digital multimeter Weight with battery: 871g Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Continuity test: acoustic indication Duty cycle factor: 1...99% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 10000000...50nS Anzahl je Verpackung: 1 Stücke |
auf Bestellung 8 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 287/EUR | FLUKE |
Description: FLUKE - FLUKE 287/EUR - Logging-Multimeter für Elektronik, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig tariffCode: 90303100 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 0.5Gohm Messwert Gleichstrom, max.: 10A rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a euEccn: NLR DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur Produktpalette: Multicomp Pro RJ45 Adapter productTraceability: No Messwert Wechselstrom, max.: 10A |
auf Bestellung 47 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+9 |
FLUKE 287/FVF/EUR | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; Software: Fluke View Forms Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341 Software: Fluke View Forms Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280 Type of meter: digital multimeter Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 4 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 287/FVF/EUR | FLUKE |
Description: FLUKE - FLUKE 287/FVF/EUR - Tragbares Digitalmultimeter, mit Forms-Software & Kabel, Echteffektiv / TRMS tariffCode: 90303200 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 0.5Gohm Messwert Gleichstrom, max.: 10A rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Schritte: 50000 Herstellergewährleistung: Lebenslang euEccn: NLR Anzahl der Stellen: 4.75 DMM-Messverfahren: Echteffektivwert DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Frequenz, Widerstand, Temperatur Produktpalette: Multicomp Pro RJ45 Adapter productTraceability: No Messwert Wechselstrom, max.: 10A Bereichswahl: Automatisch, manuell SVHC: No SVHC |
auf Bestellung 6 Stücke: Lieferzeit 14-21 Tag (e) |
||||||||||||||||
+8 |
FLUKE 289 | FLUKE |
Category: Portable digital multimeters Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54 Kind of display used: colour; LCD TFT 2,2" Display parameters: (50000) Manufacturer series: FOX Display resolution: 320x240 Power supply: battery LR6 AA 1,5V x6 Battery/ rechargeable battery: battery LR6 AA 1,5V x6 Software: Fluke Connect (FLK-IR3000FC) Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz IP rating: IP54 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A Temperature measuring range: -200...1350°C True effective value measurement: True RMS AC; True RMS AC+DC Bargraph: 51 segm. Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature Dimensions (W x H x D): 102x222x60mm AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s) Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF Diode test: 1mA @3.1V Frequency measuring accuracy: ±(0.005%+5 digit) Capacitance measuring accuracy: ±(1%+ 5 digit) AC current measuring accuracy: ±(0.6% + 5 digit) DC voltage measuring accuracy: ±(0.025% + 2 digit) DC current measuring accuracy: ±(0.15% + 2 digit) AC voltage measuring accuracy: ±(0.4% + 20 digit) Conductance measuring accuracy: ±(1% + 10digit) Resistance measuring accuracy: ±(0.05%+2 digit) Temperature measurement accuracy: ±(1% + 1°C) Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Measurement memory: 10k Standard equipment: FLK-TL175 test leads; holder for probes Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function Type of meter: digital multimeter Weight with battery: 871g Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set Continuity test: acoustic indication Duty cycle factor: 1...99% Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1% Pollution degree: 2 Temperature measurement resolution: 0.1°C Conductance measurement: 10000000...50nS Anzahl je Verpackung: 1 Stücke |
auf Bestellung 18 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||||||||
FLUKE 289/EUR | FLUKE |
Description: FLUKE - FLUKE 289/EUR - Multimeter, Industrie, Fluke 289, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig tariffCode: 90303100 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 0.5Gohm Messwert Gleichstrom, max.: 10A rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a euEccn: NLR DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur Produktpalette: - productTraceability: No Messwert Wechselstrom, max.: 10A |
auf Bestellung 50 Stücke: Lieferzeit 14-21 Tag (e) |
FLUKE 107 |
Hersteller: FLUKE
FLK-107 Portable digital multimeters
FLK-107 Portable digital multimeters
auf Bestellung 41 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 159.73 EUR |
FLUKE 113 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Type of meter: digital multimeter
Measurement: capacitance; DC voltage; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 1mV...6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Diode test: 1.2mA @2.7V
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 404g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 84x167x46mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 110
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); VDC: 1mV÷6V,60V,600V
Type of meter: digital multimeter
Measurement: capacitance; DC voltage; resistance
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
DC voltage measuring range: 1mV...6V; 60V; 600V
DC voltage measuring accuracy: ±(0.5% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Diode test: 1.2mA @2.7V
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
Weight with battery: 404g
Power supply: battery 6LR61 9V x1
Standard equipment: FLK-TL75 test leads
Conform to the norm: CAT III 600V; EN 61010
Dimensions (W x H x D): 84x167x46mm
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low impedance measuring function for checking simultaneously circuit voltage and continuity (VCHEK); low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Battery/ rechargeable battery: battery 6LR61 9V x1
Manufacturer series: Fluke 110
Anzahl je Verpackung: 1 Stücke
auf Bestellung 13 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 221.36 EUR |
Fluke 114 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC voltage; DC voltage; resistance
Dimensions (W x H x D): 84x167x46mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-221; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC voltage; DC voltage; resistance
Dimensions (W x H x D): 84x167x46mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 290 EUR |
FLUKE 115 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5543B; POM-6275; POM-6343
Manufacturer series: Fluke 110
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Related items: POM-5543B; POM-6275; POM-6343
Manufacturer series: Fluke 110
Standard equipment: FLK-TL75 test leads
Measuring instrument features: auto and manual ranging; automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Continuity test: acoustic indication; <20Ω
Pollution degree: 2
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Anzahl je Verpackung: 1 Stücke
auf Bestellung 33 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 337.98 EUR |
FLUKE 116 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0,1% + 2 digits)
Weight with battery: 550g
Power supply: battery 6LR61 9V x1
Measuring instruments application: heating and air-conditioning technology
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Manufacturer series: Fluke 110
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 84x167x46mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 2583601
Continuity test: acoustic indication; <20Ω
Frequency measuring accuracy: ±(0,1% + 2 digits)
Capacitance measuring accuracy: ±(1,9% + 2 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
AC current measuring accuracy: ±(1,5% + 3 digits)
DC current measuring accuracy: ±(1% + 2 digits)
AC voltage measuring accuracy: ±(1% + 3 digits)
True effective value measurement: True RMS AC
DC voltage measuring accuracy: ±(0,5% + 2 digits)
Bargraph: 33 segm. 32x/s
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Pollution degree: 2
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); I DC: 0.1÷600uA
Type of meter: digital multimeter
Kind of display used: LCD
Display parameters: 3,75 digit (6000)
Temperature measuring range: -40...400°C
Temperature measurement accuracy: ±(0,1% + 2 digits)
Weight with battery: 550g
Power supply: battery 6LR61 9V x1
Measuring instruments application: heating and air-conditioning technology
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; microamperes for testing flame sensors; resistance; temperature
Manufacturer series: Fluke 110
Conform to the norm: CAT III 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 84x167x46mm
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 2583601
Continuity test: acoustic indication; <20Ω
Frequency measuring accuracy: ±(0,1% + 2 digits)
Capacitance measuring accuracy: ±(1,9% + 2 digits)
Resistance measuring accuracy: ±(0,9% + 1 digit)
AC current measuring accuracy: ±(1,5% + 3 digits)
DC current measuring accuracy: ±(1% + 2 digits)
AC voltage measuring accuracy: ±(1% + 3 digits)
True effective value measurement: True RMS AC
DC voltage measuring accuracy: ±(0,5% + 2 digits)
Bargraph: 33 segm. 32x/s
AC current measuring range: 0.1...600µA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 0.1...600µA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Pollution degree: 2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 410.41 EUR |
FLUKE 116 |
Hersteller: FLUKE
Description: FLUKE - FLUKE 116 - Digitalmultimeter, HLK, Baureihe 110, 6000 Zählwerte, TRMS, auto/manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 600V
Messwert Wechselspannung, max.: 600V
Messwert Widerstand, max.: 40Mohm
Messwert Gleichstrom, max.: 600µA
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Widerstand, Temperatur
Produktpalette: 110 Series
productTraceability: No
Messwert Wechselstrom, max.: 600µA
Description: FLUKE - FLUKE 116 - Digitalmultimeter, HLK, Baureihe 110, 6000 Zählwerte, TRMS, auto/manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 600V
Messwert Wechselspannung, max.: 600V
Messwert Widerstand, max.: 40Mohm
Messwert Gleichstrom, max.: 600µA
rohsCompliant: Y-EX
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Widerstand, Temperatur
Produktpalette: 110 Series
productTraceability: No
Messwert Wechselstrom, max.: 600µA
auf Bestellung 16 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 116/323 |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296029
Anzahl je Verpackung: 1 Stücke
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-116; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296029
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 606.59 EUR |
FLUKE 117 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 600V; EN 61010
Standard equipment: FLK-TL75 test leads
Optional equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-80PJ-EXT drop-like J-type temperature probe; FLK-C25 soft cover; FLK-C50 soft cover; FLK-TL175 test leads; FLK-TLK289 accessory set; FLK-TOOLPAK strap with magnet for suspending the meter; Set of FLK-MC6 clothes; set of test leads with probes FLK-TL910; test leads FLK-TL71; test leads FLK-TL76; test leads FLK-TL224 SureGrip; test leads FLK-TL-222
Pollution degree: 2
Related items: POM-5673B; POM-5900A/POM; POM-7519A
Manufacturer series: Fluke 110
True effective value measurement: True RMS AC
Bargraph: 33 segm. 32x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Dimensions (W x H x D): 84x167x46mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.5% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 2 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; automatic AC/DC voltage selection (AutoVolt); automatic power-off; HOLD function; impact resistant holster; low battery indicator; low input impedance function (LoZ); MIN/MAX/MEDIUM function; removable holster
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 423.41 EUR |
FLUKE 117 |
Hersteller: Fluke
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 46 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 510.89 EUR |
2+ | 485.99 EUR |
3+ | 461.75 EUR |
5+ | 432.46 EUR |
10+ | 404.65 EUR |
20+ | 378.21 EUR |
FLUKE 117 |
Hersteller: Fluke
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
ELECTRICIANS MULTIMETER WITH NON-CONTACT VOLTAGE
auf Bestellung 84 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 510.89 EUR |
2+ | 485.99 EUR |
3+ | 461.75 EUR |
5+ | 432.46 EUR |
10+ | 404.65 EUR |
20+ | 378.21 EUR |
50+ | 353.05 EUR |
Fluke 117/323 |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296034
Anzahl je Verpackung: 1 Stücke
Category: Multimeters - Sets
Description: Measuring kit: multimeters
Type of measuring kit: multimeters
Standard equipment: case FLK-C115; clamp meter FLK-323; digital multimeter FLK-117; FLK-TL75 test leads; magnetic hanging strap FLK-TOOLPAK; user's manual
Battery/ rechargeable battery: battery 6LR61 9V x1; battery LR03 AAA 1,5V x2
Alias: 4296034
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 590.28 EUR |
FLUKE 117/PRV240 |
Hersteller: FLUKE
Description: FLUKE - FLUKE 117/PRV240 - Digitalmultimeter, Kit, DMM FLUKE-117 & Prüfeinheit Fluke PRV240
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
Description: FLUKE - FLUKE 117/PRV240 - Digitalmultimeter, Kit, DMM FLUKE-117 & Prüfeinheit Fluke PRV240
tariffCode: 90303100
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)Fluke 123B |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2800.96 EUR |
Fluke 123B/S |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 20MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 20n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 20MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 20n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 3601.68 EUR |
Fluke 124B |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp; FLK-I400S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 3361.67 EUR |
Fluke 125B |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Related items: POM-72941; POM-72942
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; FLK-I400S - current clamp
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 4014.22 EUR |
Fluke 125B/S |
Hersteller: FLUKE
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
Category: Portable Oscilloscopes, Scopemeters
Description: Scopemeter; 40MHz; colour,LCD TFT 5,7"; Ch: 2; 40Msps; 10n÷60s/div
Kind of display used: colour; LCD TFT 5,7"
Manufacturer series: FLUKE 120B
Number of channels: 2
Display resolution: 640x480
Additional functions: multimeter
Band: 40MHz
Software: Fluke View
Dimensions: 259x132x55mm
Continuity test: acoustic indication
Sampling: 40Msps
Type of oscilloscope: scopemeter
Plug variant: EU
Conform to the norm: CAT II 750V; CAT IV 600V; EN 61010
Measurement: active power; AC voltage; apparent power; capacitance; DC voltage; energy; harmonics; power factor; reactive power; resistance
IP rating: IP51
Time base: 10n...60s/div
Resistance measuring range: 50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ
DC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
AC voltage measuring range: 500mV; 5V; 50V; 500V; 750V
Capacitance measuring range: 50nF; 500nF; 5µF; 50µF; 500µF
Diode test: 0.5mA @2.8V
Battery/ rechargeable battery: rechargeable battery Li-Ion 10,8V x1
Power supply: power supply 17,8V DC; rechargeable battery Li-Ion 10,8V x1
Standard equipment: 2 x shielded test lead with ground lead; adapter WiFi USB; battery charger/power supply; black test lead; blue and red grapple hook; BNC to banana plug adapter; case; FLK-I400S - current clamp; magnetic hanging strap; screen protector
Resistance measuring accuracy: ±(0.6%+5 digit)
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Measuring instrument features: 20 screens memory; Connect-and-View function that ensures stable, reliable and repeatable signal display without operator; external optically isolated USB interface to transfer, archive and analyze scope or meter data; IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal; rugged design to withstand 3g Vibration, 30g shock; set actual value to reference; WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; FLK-I310S - current clamp
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 4691.5 EUR |
FLUKE 1503 |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 200MΩ; 500MΩ; 2GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic discharge of capacitance charge function; automatic power-off; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 656.37 EUR |
FLUKE 1507 |
Hersteller: FLUKE
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
Category: Insulation Resistance Meters
Description: Meter: insulation resistance; LCD; VAC: 100mV÷600V; 50÷400Hz; IP40
Conform to the norm: CAT IV 600V; EN 61010
Standard equipment: crocodile clips; FLK-TL224 silicone test leads set; FLK-TP74 lamel tip test probes; test probe FLK-TP165X
Optional equipment: crocodile clip FLK-AC285; FLK-C25 soft cover; FLK-C101 hard case; FLK-TL81A accessory set; FLK-TL225 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP40
Related items: POM-5674C; POM-5907A; POM-6041B
Automatic discharging capacitance: max. 1µF
Open circuit test voltage: 4...8V
Measurement: AC voltage; DC voltage; insulation resistance; resistance
Bandwidth for AC voltage measurements: 50...400Hz
Test voltage: 50V DC; 100V DC; 250V DC; 500V DC; 1kV DC
Resistance measuring range: 10mΩ...20Ω; 200Ω; 2kΩ; 20kΩ
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...20MΩ; 50MΩ; 100MΩ; 200MΩ; 500MΩ; 2GΩ; 10GΩ
DC voltage measuring accuracy: ±(2% + 3 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.5%+3 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Body dimensions: 203x100x50mm
Illumination: yes
Measuring instrument features: automatic calculation of polarization index; automatic discharge of capacitance charge function; automatic power-off; automatic quotient of dielectric absorption function; comparison function for fast realisation of repeated tests; insulation test stop function in case of detection of voltage over 30V; pushbutton-controlled test probe; wide test voltages selection
Type of meter: insulation resistance
Weight with battery: 550g
Continuity test: acoustic indication
Capacitance discharge time: <0.5s
Anzahl je Verpackung: 1 Stücke
auf Bestellung 6 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 817.67 EUR |
FLUKE 1560856 |
Hersteller: FLUKE
Category: Accessories - Others
Description: Display; FLK-177EGFID
Type of test accessories: display
Related items: FLK-177EGFID
Alias: 1560856
Anzahl je Verpackung: 1 Stücke
Category: Accessories - Others
Description: Display; FLK-177EGFID
Type of test accessories: display
Related items: FLK-177EGFID
Alias: 1560856
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
3+ | 29.1 EUR |
FLUKE 1577 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; DC current; DC voltage; insulation resistance; resistance
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V; 1kV
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
AC current measuring accuracy: ±(2% + 2 digit)
DC voltage measuring accuracy: ±(0.2% + 2 digit)
DC current measuring accuracy: ±(1% + 2 digit)
AC voltage measuring accuracy: ±(2% + 3 digit)
Resistance measuring accuracy: ±(1.2%+2 digit)
Insulation resistance measuring accuracy: ±(2% + 5digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1049.42 EUR |
FLUKE 1587 FC |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: Bluetooth
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; Bluetooth; LCD; (6000); I DC: 0.01÷60mA,400mA
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC285; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Optional equipment: FLK-C25 soft cover
IP rating: IP40
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5906A; POM-5907A; POM-6041B
Temperature measuring range: -40...537°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 500V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 0.1...60MΩ; 500MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Insulation resistance measuring accuracy: ±(1.5% + 5digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Interface: Bluetooth
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; HOLD function; indicates incorrect connection of test leads; insulation resistance test
Type of meter: digital multimeter
Weight with battery: 550g
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Anzahl je Verpackung: 1 Stücke
auf Bestellung 20 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1297.15 EUR |
FLUKE 1587MDT FC |
Hersteller: FLUKE
Category: Multimeters - Sets
Description: Measuring kit: multimeters; POM-5906A,POM-5907A,POM-6041B
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type temperature probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Anzahl je Verpackung: 1 Stücke
Category: Multimeters - Sets
Description: Measuring kit: multimeters; POM-5906A,POM-5907A,POM-6041B
Standard equipment: crocodile clips FLK-AC285; digital multimeter FLK-1587FC; FLK-80BK-A drop-like K-type temperature probe; FLK-I400 - current clamp; hard case; phase sequence tester FLK-9040; test leads FLK-TL224 SureGrip; test probe FLK-TP165X; user's manual
Related items: POM-5906A; POM-5907A; POM-6041B
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Type of measuring kit: multimeters
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1745.86 EUR |
FLUKE 1587T |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Measuring instrument features: auto and manual ranging; automatic discharge of capacitance charge function; automatic power-off; automatic stop of insulation test when voltage higher than 30V is detected; for telecommunication; HOLD function; indicates incorrect connection of test leads; insulation resistance test; MIN/MAX/MEDIUM function
Type of meter: digital multimeter
Optional equipment: FLK-C25 soft cover
Continuity test: acoustic indication; <25Ω
Temperature measurement resolution: 0.1°C
Temperature measuring range: -40...537°C
True effective value measurement: True RMS
Measurement: AC current; capacitance; DC current; frequency; insulation resistance; resistance; temperature
Dimensions (W x H x D): 100x203x50mm
Test voltage: 50V; 100V
AC current measuring range: 10µA...60mA; 400mA
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1mA @6V
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Insulation resistance measuring ranges: 10kΩ...100MΩ
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 2 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+2 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
IP rating: IP40
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Illumination: yes
Standard equipment: crocodile clips FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; harda case FLK-C101; test leads FLK-TL224 SureGrip; test probe FLK-TP165X
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1206.02 EUR |
FLUKE 1630-2 FC |
Hersteller: FLUKE
Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
Anzahl je Verpackung: 1 Stücke
Category: Clamp Meters - Others
Description: Meter: grounding resistance; pincers type; LCD; (9999)
Type of meter: grounding resistance
Kind of meter: pincers type
Kind of display used: LCD
Display parameters: (9999)
Measurement: leakage current; resistance
Interface: Bluetooth
Battery/ rechargeable battery: battery 6LR61 9V x1
Alias: 4829532
Resistance measuring range: 25mΩ; 250mΩ; 10Ω; 100Ω; 200Ω; 0.4kΩ; 600Ω; 1.5kΩ
Resistance measuring accuracy: ±(1,5% + 3 digits)
Continuity test: acoustic indication
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2380.92 EUR |
FLUKE 1662 |
Hersteller: FLUKE
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; RCD test: general purpose; FLK-1660
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546944
Illumination: yes
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Insulation resistance measuring ranges: 0.01...100MΩ; 200MΩ; 500MΩ; 1000MΩ
Test voltage: 100V; 250V; 500V; 1kV
Anzahl je Verpackung: 1 Stücke
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; RCD test: general purpose; FLK-1660
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546944
Illumination: yes
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Insulation resistance measuring ranges: 0.01...100MΩ; 200MΩ; 500MΩ; 1000MΩ
Test voltage: 100V; 250V; 500V; 1kV
Anzahl je Verpackung: 1 Stücke
auf Bestellung 9 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1466.97 EUR |
FLUKE 1662 UK |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1662 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
SVHC: No SVHC (20-Jun-2016)
Description: FLUKE - FLUKE 1662 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 3 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1663 |
Hersteller: FLUKE
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 100mΩ÷200Ω,2kΩ
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; earthing resistance; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546980
Illumination: yes
Insulation resistance measuring ranges: 0.01...50MΩ; 100MΩ; 200MΩ; 500MΩ; 1000MΩ
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Test voltage: 50V; 100V; 250V; 500V; 1kV
Earthing resistance measuring range: 100mΩ...200Ω; 2kΩ
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 100mΩ÷200Ω,2kΩ
Type of meter: appliance meter
Kind of display used: LCD
Measurement: AC voltage; earthing resistance; frequency; insulation resistance; RCD tripping current; RCD tripping time
AC voltage measuring range: 100mV...500V
AC voltage measuring accuracy: ±(0,8% + 3 digits)
Power supply: battery LR6 AA 1,5V x6
Plug variant: EU
Measuring instrument features: checks conductors polarization
Standard equipment: 3 crocodile clips; carrying strap; test leads; test mains cable; test probe FLK-TP165X; TL-L1 red test lead; TL-L2 blue test lead; TL-L2 green test lead; user's manual
Body dimensions: 100x250x125mm
Manufacturer series: FLK-1660
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
RCD test: general purpose
Alias: 4546980
Illumination: yes
Insulation resistance measuring ranges: 0.01...50MΩ; 100MΩ; 200MΩ; 500MΩ; 1000MΩ
Earthing resistance measuring accuracy: ±(2% + 5 digits)
Test voltage: 50V; 100V; 250V; 500V; 1kV
Earthing resistance measuring range: 100mΩ...200Ω; 2kΩ
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2002.37 EUR |
FLUKE 1663 UK |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1663 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
Description: FLUKE - FLUKE 1663 UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 Series
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1664 FC EU |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1664 FC EU - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
Description: FLUKE - FLUKE 1664 FC EU - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: TBA
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1664 FC UK |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1664 FC UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
SVHC: No SVHC (20-Jun-2016)
Description: FLUKE - FLUKE 1664 FC UK - Multifunktions-Installationstester, Produktreihe 1660, max. 500V AC, max. 500V DC, 20 MOhm-1000 MOhm
tariffCode: 90303370
productTraceability: No
Isolationswiderstand, max.: 1000Mohm
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 500V
Messwert Wechselspannung, max.: 500V
Isolationswiderstand, min.: 20Mohm
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Produktpalette: 1660 FC Series
SVHC: No SVHC (20-Jun-2016)
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1664FC |
Hersteller: FLUKE
FLK-1664FC-SCH Multimeters for Electrical Installations
FLK-1664FC-SCH Multimeters for Electrical Installations
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2606.46 EUR |
FLUKE 166X MTC SCH |
Hersteller: FLUKE
Description: FLUKE - FLUKE 166X MTC SCH - Konfektionierte Messleitung, Netzmessleitung Fluke 166X, SCHUKO (EU)
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Zur Verwendung mit: -
usEccn: EAR99
Produktpalette: 1660 Series
Description: FLUKE - FLUKE 166X MTC SCH - Konfektionierte Messleitung, Netzmessleitung Fluke 166X, SCHUKO (EU)
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Zur Verwendung mit: -
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 166X MTC UK |
Hersteller: FLUKE
Description: FLUKE - FLUKE 166X MTC UK - Konfektioniertes Prüfkabel, Netzkabel, Multifunktionstester der Baureihe 1660 von Fluke
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: 1660 Series
Description: FLUKE - FLUKE 166X MTC UK - Konfektioniertes Prüfkabel, Netzkabel, Multifunktionstester der Baureihe 1660 von Fluke
tariffCode: 85444290
productTraceability: No
rohsCompliant: YES
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: EAR99
Produktpalette: 1660 Series
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 175 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.15% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 48 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 432.43 EUR |
FLUKE 177 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.09% + 2 digit)
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance
Manufacturer series: Fluke 170
Power supply: battery 6LR61 9V x1
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Standard equipment: FLK-TL75 test leads
Battery/ rechargeable battery: battery 6LR61 9V x1
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Kind of display used: LCD
Type of meter: digital multimeter
Weight with battery: 420g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Continuity test: acoustic indication; <25Ω
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Dimensions (W x H x D): 89x190x45mm
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Anzahl je Verpackung: 1 Stücke
auf Bestellung 29 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 523.38 EUR |
FLUKE 179 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 46 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 641.21 EUR |
FLUKE 179 MAG KIT |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; mini torch; test leads FLK-TL224 SureGrip; test probes FLK-AC220 SureGrip; test probes FLK-TP4
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6F22 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 37 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 593.34 EUR |
FLUKE 179/EDA2/EUR |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; POM-5904A/POM,POM-6343,POM-7519A
Standard equipment: digital multimeter FLK-179EGFID; FLK-80BK-A drop-like K-type temperature probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; set of test leads with probes FLK-TL910; test leads FLK-TL224 SureGrip; test probes FLK-AC280 SureGrip
Related items: POM-5904A/POM; POM-6343; POM-7519A
Battery/ rechargeable battery: battery 6LR61 9V x1
Type of meter: digital multimeter
Anzahl je Verpackung: 1 Stücke
auf Bestellung 12 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 685.13 EUR |
FLUKE 179/TL-223 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads; FLK-TL-223 set
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; 3,75 digit (6000); True RMS AC
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: FLK-80BK-A drop-like K-type temperature probe; FLK-TL75 test leads; FLK-TL-223 set
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C90 soft cover; FLK-TLK220 set
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5904A/POM; POM-6343; POM-7519A
Manufacturer series: Fluke 170
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Bargraph: 33 segm. 40x/s
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 89x190x45mm
AC current measuring range: 10µA...60mA; 400mA; 6A; 10A
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
DC current measuring range: 10µA...60mA; 400mA; 6A; 10A
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 99.99kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.1mA @2.4V
Battery/ rechargeable battery: battery 6LR61 9V x1
Display parameters: 3,75 digit (6000)
Frequency measuring accuracy: ±(0.1%+1 digit)
Capacitance measuring accuracy: ±(1.2%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.09% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery 6LR61 9V x1
Measuring instrument features: auto and manual ranging; dangerous voltage alarm (over 30V); HOLD function; impact resistant holster; indicates incorrect connection of test leads; low battery indicator; MIN/MAX/MEDIUM function; settable standby mode; smoothing mode that enables to filter quick changing input signals
Type of meter: digital multimeter
Weight with battery: 420g
Continuity test: acoustic indication; <25Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 706.06 EUR |
FLUKE 1AC II |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1AC II - Spannungsprüfer, berührungslos, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992
Produktpalette: Multicomp Pro RJ45 Adapter
Description: FLUKE - FLUKE 1AC II - Spannungsprüfer, berührungslos, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 34 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1AC-2-5PK |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage; set of 5 detectors
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage; set of 5 detectors
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 192.15 EUR |
FLUKE 1AC-E1-II |
Hersteller: FLUKE
Description: FLUKE - FLUKE 1AC-E1-II - Spannungsprüfer, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
Description: FLUKE - FLUKE 1AC-E1-II - Spannungsprüfer, 200V bis 1kV, LED, -10 °C, 50 °C
tariffCode: 90303370
productTraceability: No
rohsCompliant: Y-EX
euEccn: NLR
Netzsteckertyp: -
hazardous: false
rohsPhthalatesCompliant: TBA
Betriebstemperatur, min.: -10°C
Betriebstemperatur, max.: 50°C
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 1AC-E2-II |
Hersteller: FLUKE
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
Category: Indicators, Voltage & Continuity Testers
Description: Tester: non-contact voltage detector; 200÷1000VAC; IP40
Type of tester: non-contact voltage detector
Detected voltage range: 200...1000V AC
IP rating: IP40
Conform to the norm: CAT IV 1000V; EN 61010
Power supply: battery LR03 AAA 1,5V x2
Measuring instrument features: AutoTest function; optical (LED) and acoustic indication of detected voltage
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Anzahl je Verpackung: 1 Stücke
auf Bestellung 24 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
2+ | 49.58 EUR |
FLUKE 2042T |
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Transmitter; FLK-2042
Type of test accessories: transmitter
Related items: FLK-2042
Alias: 2435045
Anzahl je Verpackung: 1 Stücke
Category: Metals & cables detectors
Description: Transmitter; FLK-2042
Type of test accessories: transmitter
Related items: FLK-2042
Alias: 2435045
Anzahl je Verpackung: 1 Stücke
Produkt ist nicht verfügbar
FLUKE 2052 |
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 2,5",LED; IP40
Kind of display used: LCD 2,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Receiver dimensions: 183x75x43mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 2,5",LED; IP40
Kind of display used: LCD 2,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; sorting bundled wires
Receiver dimensions: 183x75x43mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1848.13 EUR |
FLUKE 2062 PRO |
Hersteller: FLUKE
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 3,5",LED; IP40
Kind of display used: LCD 3,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Receiver dimensions: 277x112x65mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
Category: Metals & cables detectors
Description: Non-contact metal and voltage detector; LCD 3,5",LED; IP40
Kind of display used: LCD 3,5"; LED
Kit contents: case; current clamp; jumper wire set; manual; receiver; socket -check adapter; transmitter
Power supply: rechargeable battery Ni-MH AA 1,2V x12
Battery/ rechargeable battery: rechargeable battery Ni-MH AA 1,2V x12
Measuring instrument features: contactless voltage detector; detects discontinuities and short circuits in cables; detects wires in ceilings, walls and floors; Smart Sensor™; sorting bundled wires
Receiver dimensions: 277x112x65mm
Transmitter dimensions: 183x93x50mm
Type of tester: non-contact metal and voltage detector
Conform to the norm: CAT IV 600V; EN 61010
Detection: energized up to 4,5m (open air); energized up to 6,1m (open air); localisation of wire breaks; localizes breakers and fuses; NCV voltage at depth up to 2m (open air)
Output signal: de-energized mode (0...30V AC/DC) 33kHz; energized mode (30...600V AC/DC) 6kHz
Detected voltage range: 0...600V AC; 0...600V DC
IP rating: IP40
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2977.26 EUR |
FLUKE 233 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-TL175 test leads; FLK-TOOLPAK strap with magnet for suspending the meter; soft carrying case FLK-C35; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5900A/POM; POM-6172A; POM-7519A
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 93x193x53mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery LR6 AA 1,5V x5
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.25% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x5
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; radio connection indicator; wireless display (range up to 10m)
Type of meter: digital multimeter
Weight with battery: 604g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); VDC: 0.1÷600mV,6V,60V,600V,1kV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Standard equipment: crocodile clips FLK-AC72; FLK-80BK-A drop-like K-type temperature probe; test leads
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-TL175 test leads; FLK-TOOLPAK strap with magnet for suspending the meter; soft carrying case FLK-C35; test leads FLK-TL71; test leads FLK-TL224 SureGrip
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5900A/POM; POM-6172A; POM-7519A
Temperature measuring range: -40...400°C
True effective value measurement: True RMS AC
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Dimensions (W x H x D): 93x193x53mm
AC current measuring range: 1mA...6A; 10A; (20A <30s)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 40MΩ
DC current measuring range: 1mA...6A; 10A; 20A < 30s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 10mHz...99.99Hz; 999.9Hz; 9.999kHz; 50kHz
Capacitance measuring range: 1nF...1µF; 10µF; 100µF; 9.999mF
Diode test: 1.2mA @2.7V
Battery/ rechargeable battery: battery LR6 AA 1,5V x5
Display parameters: (6000)
Frequency measuring accuracy: ±(0.1%+2 digit)
Capacitance measuring accuracy: ±(1.9%+ 2 digit)
AC current measuring accuracy: ±(1.5% + 3 digit)
DC voltage measuring accuracy: ±(0.25% + 2 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Resistance measuring accuracy: ±(0.9%+1 digit)
Temperature measurement accuracy: ±(1% + 10 digit)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x5
Illumination: yes
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; HOLD function; low battery indicator; MIN/MAX/MEDIUM function; radio connection indicator; wireless display (range up to 10m)
Type of meter: digital multimeter
Weight with battery: 604g
Continuity test: acoustic indication; <20Ω
Anzahl je Verpackung: 1 Stücke
auf Bestellung 7 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 636.64 EUR |
FLUKE 27-II |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(2% + 3 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1.5% + 2 digit)
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; HOLD function; MIN/MAX/MEAN/REL function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1027.71 EUR |
FLUKE 279 FC/IFLEX |
Hersteller: Fluke
FLUKE 279 FC/IFLEX
FLUKE 279 FC/IFLEX
auf Bestellung 2 Stücke:
Lieferzeit 14-21 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2315.95 EUR |
2+ | 2204.59 EUR |
FLUKE 279FC/IFLEX |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Refresh rate: 8Hz
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Plug variant: EU
Camera resolution: 80x60
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter with infrared camera; Bluetooth; Plug: EU
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5677B; POM-5899A; POM-7519A
Interface: Bluetooth
Measurement: AC current; AC voltage; capacitance; DC voltage; frequency; non-contact temeprature (IR); resistance
Refresh rate: 8Hz
Standard equipment: battery charger/power supply; case; FLK-I2500-18 flexible current probe; FLK-TL175 test leads
Type of meter: digital multimeter with infrared camera
Continuity test: acoustic indication; <25Ω
Non-contact temperature measuring range: -10...200°C
Emissivity value: 0,95 (fixed)
Focusing: focus free
Plug variant: EU
Camera resolution: 80x60
Dimensions (W x H x D): 93.9x215.9x57.1mm
Thermal sensitivity (NETD): ≤0.2°C
AC current measuring range: 100mA...999.9A; 2.5kA
Resistance measuring range: 600Ω...50MΩ
DC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
AC voltage measuring range: 600mV; 6V; 60V; 600V; 1kV
Frequency measuring range: 99.99...999.9Hz
Capacitance measuring range: 1000nF...9999µF
Diode test: 2V
Battery/ rechargeable battery: rechargeable battery Li-Ion 7,4V 3000mAh x1
Connectors for the country: Great Britain
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Anzahl je Verpackung: 1 Stücke
auf Bestellung 5 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1679.76 EUR |
FLUKE 27II/EUR |
Hersteller: FLUKE
Description: FLUKE - FLUKE 27II/EUR - Digitalmultimeter, IP67, Industrie, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 10A
Messwert Wechselstrom, max.: 10A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 50Mohm
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
Description: FLUKE - FLUKE 27II/EUR - Digitalmultimeter, IP67, Industrie, 20000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.5-stellig
tariffCode: 90303100
Messwert Gleichstrom, max.: 10A
Messwert Wechselstrom, max.: 10A
productTraceability: No
rohsCompliant: Y-EX
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
euEccn: NLR
hazardous: false
rohsPhthalatesCompliant: TBA
Messwert Widerstand, max.: 50Mohm
usEccn: 3A992.a
Produktpalette: Multicomp Pro RJ45 Adapter
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 28 II EX |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/19999); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/19999)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR03 AAA 1,5V x3
Standard equipment: test leads
Optional equipment: crocodile clip FLK-AC285; FLK-80BK-A drop-like K-type temperature probe; FLK-80PK-1 drop-like K-type temperature probe; FLK-80PK-8 drop-like K-type temperature probe; FLK-80PK-9 drop-like K-type temperature probe; FLK-80PK-27 drop-like K-type temperature probe; FLK-C101 hard case; FLK-TL175 test leads; test leads FLK-TL71
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; intrinsic safety; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR03 AAA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 2 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 2464.02 EUR |
FLUKE 28-II |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; True RMS
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; relative; resistance; temperature
Kind of display used: LCD
Display parameters: (6000)
Bargraph: 33 segm. 40x/s
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(1% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
DC current measuring accuracy: ±(0.2% + 2 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
Temperature measurement resolution: 0.1°C
Conductance measurement: 0.01...60nS
Duty cycle factor: 0...99.9%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Diode test: 1mA @2.8V
Continuity test: acoustic indication
IP rating: IP67
Weight with battery: 517g
Power supply: battery LR6 AA 1,5V x3
Standard equipment: test leads
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA
Dimensions (W x H x D): 100x198x63.5mm
Measuring instrument features: auto and manual ranging; automatic power-off; backlit keypad; display with high resolution (up to 20 000 samples) option; HOLD function; low-pass filter for measuring drive parameters; MIN/MAX/MEAN/REL function; PEAK HOLD MIN/MAX function; shock-resistant case
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1027.71 EUR |
FLUKE 287 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FLUKE 280
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FLUKE 280
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: holder for probes; test leads FLK-TL71
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 8 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1145.4 EUR |
FLUKE 287/EUR |
Hersteller: FLUKE
Description: FLUKE - FLUKE 287/EUR - Logging-Multimeter für Elektronik, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
Description: FLUKE - FLUKE 287/EUR - Logging-Multimeter für Elektronik, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 47 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 287/FVF/EUR |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; Software: Fluke View Forms
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5674C; POM-6340; POM-6341
Software: Fluke View Forms
Standard equipment: cable for connection with PC; crocodile clips FLK-AC72; digital multimeter FLK-287; FLK-80BK-A drop-like K-type temperature probe; FLK-TL175 test leads; holder for probes; magnetic hanging strap FLK-TOOLPAK; soft cover FLK-C280
Type of meter: digital multimeter
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Anzahl je Verpackung: 1 Stücke
auf Bestellung 4 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1338.48 EUR |
FLUKE 287/FVF/EUR |
Hersteller: FLUKE
Description: FLUKE - FLUKE 287/FVF/EUR - Tragbares Digitalmultimeter, mit Forms-Software & Kabel, Echteffektiv / TRMS
tariffCode: 90303200
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 50000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 4.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC
Description: FLUKE - FLUKE 287/FVF/EUR - Tragbares Digitalmultimeter, mit Forms-Software & Kabel, Echteffektiv / TRMS
tariffCode: 90303200
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
Schritte: 50000
Herstellergewährleistung: Lebenslang
euEccn: NLR
Anzahl der Stellen: 4.75
DMM-Messverfahren: Echteffektivwert
DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Kapazität, Durchgang, Frequenz, Widerstand, Temperatur
Produktpalette: Multicomp Pro RJ45 Adapter
productTraceability: No
Messwert Wechselstrom, max.: 10A
Bereichswahl: Automatisch, manuell
SVHC: No SVHC
auf Bestellung 6 Stücke:
Lieferzeit 14-21 Tag (e)FLUKE 289 |
Hersteller: FLUKE
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FOX
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: FLK-TL175 test leads; holder for probes
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
Category: Portable digital multimeters
Description: Digital multimeter; colour,LCD TFT 2,2"; (50000); 320x240; IP54
Kind of display used: colour; LCD TFT 2,2"
Display parameters: (50000)
Manufacturer series: FOX
Display resolution: 320x240
Power supply: battery LR6 AA 1,5V x6
Battery/ rechargeable battery: battery LR6 AA 1,5V x6
Software: Fluke Connect (FLK-IR3000FC)
Frequency measuring range: 1...99999mHz; 999.99Hz; 9.9999kHz; 99.999kHz; 999.99kHz
IP rating: IP54
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-5899A; POM-6173A; POM-7519A
Temperature measuring range: -200...1350°C
True effective value measurement: True RMS AC; True RMS AC+DC
Bargraph: 51 segm.
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; duty cycle; frequency; resistance; temperature
Dimensions (W x H x D): 102x222x60mm
AC current measuring range: 0.01...500µA; 5mA; 50mA; 400mA; 5A; 10A; (20A <30s)
Resistance measuring range: 1mΩ...50Ω; 500Ω; 5kΩ; 50kΩ; 500kΩ; 5MΩ; 30MΩ; 50MΩ; 100MΩ; 500MΩ
DC current measuring range: 10nA...500µA; 5mA; 50mA; 400mA; 5A; 10A; 20A < 30s
DC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
AC voltage measuring range: 0.1µV...50mV; 500mV; 5V; 50V; 500V; 1kV
Capacitance measuring range: 1pF...1nF; 10nF; 100nF; 1µF; 10µF; 100µF; 1mF; 10mF; 100mF
Diode test: 1mA @3.1V
Frequency measuring accuracy: ±(0.005%+5 digit)
Capacitance measuring accuracy: ±(1%+ 5 digit)
AC current measuring accuracy: ±(0.6% + 5 digit)
DC voltage measuring accuracy: ±(0.025% + 2 digit)
DC current measuring accuracy: ±(0.15% + 2 digit)
AC voltage measuring accuracy: ±(0.4% + 20 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Resistance measuring accuracy: ±(0.05%+2 digit)
Temperature measurement accuracy: ±(1% + 1°C)
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Measurement memory: 10k
Standard equipment: FLK-TL175 test leads; holder for probes
Measuring instrument features: HOLD function; information pushbutton activating the built-in help; low input impedance function (LoZ); low-pass filter for measuring drive parameters; low resistance measuring range (50Ω) for measuring motor windings resistance; MIN/MAX/MEDIUM function; possibility of displaying many readouts on single screen; quick registration of MIN/MAX values (250µs); TrendCapture data registration function
Type of meter: digital multimeter
Weight with battery: 871g
Optional equipment: FLK-C781 soft cover; FLK-IR3000FC; FLK-TLK287 accessory set; FLK-TLK289 accessory set
Continuity test: acoustic indication
Duty cycle factor: 1...99%
Duty cycle factor measurement accuracy: 0,2% per kHz + 0,1%
Pollution degree: 2
Temperature measurement resolution: 0.1°C
Conductance measurement: 10000000...50nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 18 Stücke:
Lieferzeit 7-14 Tag (e)Anzahl | Preis ohne MwSt |
---|---|
1+ | 1240.67 EUR |
FLUKE 289/EUR |
Hersteller: FLUKE
Description: FLUKE - FLUKE 289/EUR - Multimeter, Industrie, Fluke 289, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: -
productTraceability: No
Messwert Wechselstrom, max.: 10A
Description: FLUKE - FLUKE 289/EUR - Multimeter, Industrie, Fluke 289, 50000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 4.5-stellig
tariffCode: 90303100
Messwert Gleichspannung, max.: 1kV
Messwert Wechselspannung, max.: 1kV
Messwert Widerstand, max.: 0.5Gohm
Messwert Gleichstrom, max.: 10A
rohsCompliant: YES
hazardous: false
rohsPhthalatesCompliant: TBA
usEccn: 3A992.a
euEccn: NLR
DMM-Funktionen: Strom, Spannung, Kapazität, Frequenz, Widerstand, Temperatur
Produktpalette: -
productTraceability: No
Messwert Wechselstrom, max.: 10A
auf Bestellung 50 Stücke:
Lieferzeit 14-21 Tag (e)Wählen Sie Seite:
1
2
[ Nächste Seite >> ]