BF1801A230 LOVATO ELECTRIC
Hersteller: LOVATO ELECTRICCategory: Contactors - Main modules
Description: Contactor: 3-pole; NO x3; Auxiliary contacts: NC; 230VAC; 18A; BF
Mounting: for DIN rail mounting
Integrated auxiliary contacts: NC
Contacts configuration: NO x3
Leads: screw terminals
Operating temperature: -50...70°C
Width: 45mm
Height: 81mm
Control voltage: 230V AC
Max. operating current: 18A
Supply voltage frequency: 50/60Hz
Insulation voltage: 690V
Type of contactor: 3-pole
Manufacturer series: BF
auf Bestellung 32 Stücke:
Lieferzeit 14-21 Tag (e)
| Anzahl | Preis |
|---|---|
| 2+ | 60.49 EUR |
| 5+ | 57.53 EUR |
| 10+ | 54.25 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details BF1801A230 LOVATO ELECTRIC
Description: LOVATO - BF1801A230 - Schütz, 18 A, DIN-Schiene, 690 VAC, 3PST-NO, 3-polig, 10 kW, tariffCode: 85364900, Schaltleistung, AC1: 36kW, rohsCompliant: YES, hazardous: false, rohsPhthalatesCompliant: TBA, Schaltstrom AC3: 18A, Laststrom, induktiv: 18A, usEccn: EAR99, Schaltstrom AC1: 32A, Schaltleistung, AC3: 10kW, DC-Nennspannung Spule: -, euEccn: NLR, Laststrom, ohmsch: 32A, AC-Nennspannung Spule: 230V, Relaismontage: DIN-Schiene, Betriebsspannung: 690VAC, Polzahl: 3-polig, Produktpalette: BF18 Series, productTraceability: No, Kontaktkonfiguration: 3PST-NO, SVHC: No SVHC (21-Jan-2025).
Weitere Produktangebote BF1801A230 nach Preis ab 54.25 EUR bis 60.49 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BF1801A230 | Hersteller : LOVATO ELECTRIC |
Category: Contactors - Main modulesDescription: Contactor: 3-pole; NO x3; Auxiliary contacts: NC; 230VAC; 18A; BF Mounting: for DIN rail mounting Integrated auxiliary contacts: NC Contacts configuration: NO x3 Leads: screw terminals Operating temperature: -50...70°C Width: 45mm Height: 81mm Control voltage: 230V AC Max. operating current: 18A Supply voltage frequency: 50/60Hz Insulation voltage: 690V Type of contactor: 3-pole Manufacturer series: BF Anzahl je Verpackung: 1 Stücke |
auf Bestellung 32 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||||||
| BF1801A230 | Hersteller : LOVATO |
Description: LOVATO - BF1801A230 - Schütz, 18 A, DIN-Schiene, 690 VAC, 3PST-NO, 3-polig, 10 kWtariffCode: 85364900 Schaltleistung, AC1: 36kW rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: TBA Schaltstrom AC3: 18A Laststrom, induktiv: 18A usEccn: EAR99 Schaltstrom AC1: 32A Schaltleistung, AC3: 10kW DC-Nennspannung Spule: - euEccn: NLR Laststrom, ohmsch: 32A AC-Nennspannung Spule: 230V Relaismontage: DIN-Schiene Betriebsspannung: 690VAC Polzahl: 3-polig Produktpalette: BF18 Series productTraceability: No Kontaktkonfiguration: 3PST-NO SVHC: No SVHC (21-Jan-2025) |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |