BK-880 MPD (Memory Protection Devices)
Hersteller: MPD (Memory Protection Devices)Description: BATT RETAINER COIN 24.5MM PC PIN
Packaging: Bulk
Battery Cell Size: Coin, 24.5mm
Number of Cells: 1
Mounting Type: PCB, Through Hole
Style: Retainer
Termination Style: PC Pin
Height Above Board: 0.230" (5.85mm)
Battery Series: 2450
Battery Type, Function: Coin Cell, Retainer
Part Status: Active
auf Bestellung 22954 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 16+ | 1.14 EUR |
| 19+ | 0.95 EUR |
| 50+ | 0.84 EUR |
| 100+ | 0.79 EUR |
| 250+ | 0.73 EUR |
| 500+ | 0.69 EUR |
| 1000+ | 0.66 EUR |
| 3000+ | 0.6 EUR |
| 5000+ | 0.58 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details BK-880 MPD (Memory Protection Devices)
Category: LCR Meter, Description: LCR meter; LCD; (10000),(40000); 4x/s; 4pF÷20mF; Accuracy: 0.1%, Type of meter: LCR meter, Kind of display used: LCD, Display parameters: (10000); (40000), Resistance measuring range: 400mΩ; 4Ω; 40Ω; 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 10MΩ, Capacitance measuring range: 4pF...20mF, Measurement: capacitance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; resistance, Inductance measuring range: 4µH...1kH, Interface: USB, Battery/ rechargeable battery: battery 6LR61 9V x1, Power supply: battery 6LR61 9V x1, Dimensions: 190x90x41mm, Measuring instrument features: 4-wire measurement possibility; automatic power-off; autoranging; MIN/MAX/AVG function; settings memory, Standard equipment: Kelvin test leads; power supply AC 230V; shorting plate; test leads with crocodile clips; test tweezers; USB cable, Accuracy: 0.1%, Inductance measuring accuracy: ±(0.1% + 2 digit), Resistance measuring accuracy: ±(0.1%+2 digit), Capacitance measuring accuracy: ±(0.1%+ 2 digit), Measurement frequency: 100Hz; 120Hz; 1kHz; 10kHz; 100kHz, Weight without batteries: 348g, Sampling: 4x/s, Software: download from manufacturers website, Support: SCPI, Illumination: yes, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote BK-880
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis |
|---|---|---|---|---|---|
|
BK880 | Hersteller : B&K PRECISION |
Description: B&K PRECISION - BK880 - LCR-Messgerät, Doppelanzeige, Tragbar, 100 kHz, 1 kH, 20000 µF, 10 MohmtariffCode: 90303370 Messwert Kapazität, max.: 20000µF rohsCompliant: YES hazardous: false rohsPhthalatesCompliant: YES Messwert Induktivität, max.: 1kH isCanonical: Y usEccn: 3A992.a Gerätetyp: Tragbar Messwert Widerstand, max.: 10Mohm euEccn: NLR Prüffrequenz, max.: 100kHz Produktpalette: - productTraceability: No SVHC: No SVHC (07-Nov-2024) |
auf Bestellung 23 Stücke: Lieferzeit 14-21 Tag (e) |
|
![]() +4 |
BK880 | Hersteller : B&K PRECISION |
Category: LCR MeterDescription: LCR meter; LCD; (10000),(40000); 4x/s; 4pF÷20mF; Accuracy: 0.1% Type of meter: LCR meter Kind of display used: LCD Display parameters: (10000); (40000) Resistance measuring range: 400mΩ; 4Ω; 40Ω; 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 10MΩ Capacitance measuring range: 4pF...20mF Measurement: capacitance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; resistance Inductance measuring range: 4µH...1kH Interface: USB Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Dimensions: 190x90x41mm Measuring instrument features: 4-wire measurement possibility; automatic power-off; autoranging; MIN/MAX/AVG function; settings memory Standard equipment: Kelvin test leads; power supply AC 230V; shorting plate; test leads with crocodile clips; test tweezers; USB cable Accuracy: 0.1% Inductance measuring accuracy: ±(0.1% + 2 digit) Resistance measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(0.1%+ 2 digit) Measurement frequency: 100Hz; 120Hz; 1kHz; 10kHz; 100kHz Weight without batteries: 348g Sampling: 4x/s Software: download from manufacturers website Support: SCPI Illumination: yes Anzahl je Verpackung: 1 Stücke |
Produkt ist nicht verfügbar |
|
![]() +4 |
BK880 | Hersteller : B&K PRECISION |
Category: LCR MeterDescription: LCR meter; LCD; (10000),(40000); 4x/s; 4pF÷20mF; Accuracy: 0.1% Type of meter: LCR meter Kind of display used: LCD Display parameters: (10000); (40000) Resistance measuring range: 400mΩ; 4Ω; 40Ω; 0.4kΩ; 4kΩ; 40kΩ; 400kΩ; 4MΩ; 10MΩ Capacitance measuring range: 4pF...20mF Measurement: capacitance; DCR; dissipation factor D; equivalent series resistance (ESR); impedance; inductance; phase angle θ; quality factor Q; resistance Inductance measuring range: 4µH...1kH Interface: USB Battery/ rechargeable battery: battery 6LR61 9V x1 Power supply: battery 6LR61 9V x1 Dimensions: 190x90x41mm Measuring instrument features: 4-wire measurement possibility; automatic power-off; autoranging; MIN/MAX/AVG function; settings memory Standard equipment: Kelvin test leads; power supply AC 230V; shorting plate; test leads with crocodile clips; test tweezers; USB cable Accuracy: 0.1% Inductance measuring accuracy: ±(0.1% + 2 digit) Resistance measuring accuracy: ±(0.1%+2 digit) Capacitance measuring accuracy: ±(0.1%+ 2 digit) Measurement frequency: 100Hz; 120Hz; 1kHz; 10kHz; 100kHz Weight without batteries: 348g Sampling: 4x/s Software: download from manufacturers website Support: SCPI Illumination: yes |
Produkt ist nicht verfügbar |

