BM157S BRYMEN

Category: Meters and AC Clamp Probes
Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g
Kind of meter: pincers type
Optional equipment: KITBRUA-13X software; KITRS232E software
Kind of display used: LCD
Type of meter: power
Interface: RS232 (option); USB
True effective value measurement: True RMS AC
Illumination: yes
DC voltage measuring range: 100mV...600V
AC voltage measuring range: 100mV...600V
Apparent power measurement: 0...600kVA
Reactive power measurement: 0...600kVAR
Power factor measurement: 0.01...0.99
Frequency measuring range: 10mHz...5Hz; 500Hz
AC current measuring range: 10mA...40A; 400A; 1kA
Max. diameter of measured cable: 45mm
Dimensions: 224x78x40mm
Resistance measuring range: 100mΩ...999.9Ω
DC voltage measuring accuracy: ±(0.5% + 5 digit)
Frequency measuring accuracy: ±(0.5%+4 digit)
AC voltage measuring accuracy: ±(0.5% + 5 digit)
Resistance measuring accuracy: ±(1%+6 digit)
AC current measuring accuracy: ±(1% + 5 digit)
Pollution degree: 2
Apparent power measuring accuracy: ±(3.5% + 6 digit)
Active power measuring accuracy: ±(4.5% + 6 digit)
Reactive power measuring accuracy: ±(4.5% + 6 digit)
Bandwidth for AC current measurements: 40...500Hz
Bandwidth for AC voltage measurements: 40...500Hz
Weight with battery: 224g
Harmonic content measurement: 0...99,99%
Sampling: 1x/s (Hz); 2x/s
Harmonic content measuring accuracy: ±(1% + 6 digits)
Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance
Continuity test: acoustic indication; 50Ω...250Ω
Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals
Power supply: battery LR03 AAA 1,5V x2
Battery/ rechargeable battery: battery LR03 AAA 1,5V x2
Standard equipment: case; test leads
Conform to the norm: CAT III 600V; EN 61010
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Anzahl | Preis |
---|---|
1+ | 223.28 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details BM157S BRYMEN
Category: Meters and AC Clamp Probes, Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g, Kind of meter: pincers type, Optional equipment: KITBRUA-13X software; KITRS232E software, Kind of display used: LCD, Type of meter: power, Interface: RS232 (option); USB, True effective value measurement: True RMS AC, Illumination: yes, DC voltage measuring range: 100mV...600V, AC voltage measuring range: 100mV...600V, Apparent power measurement: 0...600kVA, Reactive power measurement: 0...600kVAR, Power factor measurement: 0.01...0.99, Frequency measuring range: 10mHz...5Hz; 500Hz, AC current measuring range: 10mA...40A; 400A; 1kA, Max. diameter of measured cable: 45mm, Dimensions: 224x78x40mm, Resistance measuring range: 100mΩ...999.9Ω, DC voltage measuring accuracy: ±(0.5% + 5 digit), Frequency measuring accuracy: ±(0.5%+4 digit), AC voltage measuring accuracy: ±(0.5% + 5 digit), Resistance measuring accuracy: ±(1%+6 digit), AC current measuring accuracy: ±(1% + 5 digit), Pollution degree: 2, Apparent power measuring accuracy: ±(3.5% + 6 digit), Active power measuring accuracy: ±(4.5% + 6 digit), Reactive power measuring accuracy: ±(4.5% + 6 digit), Bandwidth for AC current measurements: 40...500Hz, Bandwidth for AC voltage measurements: 40...500Hz, Weight with battery: 224g, Harmonic content measurement: 0...99,99%, Sampling: 1x/s (Hz); 2x/s, Harmonic content measuring accuracy: ±(1% + 6 digits), Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance, Continuity test: acoustic indication; 50Ω...250Ω, Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals, Power supply: battery LR03 AAA 1,5V x2, Battery/ rechargeable battery: battery LR03 AAA 1,5V x2, Standard equipment: case; test leads, Conform to the norm: CAT III 600V; EN 61010, Anzahl je Verpackung: 1 Stücke.
Weitere Produktangebote BM157S nach Preis ab 223.28 EUR bis 223.28 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
---|---|---|---|---|---|---|---|---|---|
![]() +5 |
BM157S | Hersteller : BRYMEN |
![]() Description: Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g Kind of meter: pincers type Optional equipment: KITBRUA-13X software; KITRS232E software Kind of display used: LCD Type of meter: power Interface: RS232 (option); USB True effective value measurement: True RMS AC Illumination: yes DC voltage measuring range: 100mV...600V AC voltage measuring range: 100mV...600V Apparent power measurement: 0...600kVA Reactive power measurement: 0...600kVAR Power factor measurement: 0.01...0.99 Frequency measuring range: 10mHz...5Hz; 500Hz AC current measuring range: 10mA...40A; 400A; 1kA Max. diameter of measured cable: 45mm Dimensions: 224x78x40mm Resistance measuring range: 100mΩ...999.9Ω DC voltage measuring accuracy: ±(0.5% + 5 digit) Frequency measuring accuracy: ±(0.5%+4 digit) AC voltage measuring accuracy: ±(0.5% + 5 digit) Resistance measuring accuracy: ±(1%+6 digit) AC current measuring accuracy: ±(1% + 5 digit) Pollution degree: 2 Apparent power measuring accuracy: ±(3.5% + 6 digit) Active power measuring accuracy: ±(4.5% + 6 digit) Reactive power measuring accuracy: ±(4.5% + 6 digit) Bandwidth for AC current measurements: 40...500Hz Bandwidth for AC voltage measurements: 40...500Hz Weight with battery: 224g Harmonic content measurement: 0...99,99% Sampling: 1x/s (Hz); 2x/s Harmonic content measuring accuracy: ±(1% + 6 digits) Measurement: AC current; active power; AC voltage; apparent power; DC voltage; energy; frequency; power factor; reactive power; resistance Continuity test: acoustic indication; 50Ω...250Ω Measuring instrument features: A-lags-V - indicates nature of measured circuit (inductive or capacitive); automatically selects AAC, VAC, VDC measurement on the basis of measured signal; automatic power-off; autoranging; HOLD function; kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load; PEAK HOLD function for AC measurements; PF - measures total power factor as active to apparent power quotient; THD%-F immediately evaluates harmonic content in measured voltage and current signals Power supply: battery LR03 AAA 1,5V x2 Battery/ rechargeable battery: battery LR03 AAA 1,5V x2 Standard equipment: case; test leads Conform to the norm: CAT III 600V; EN 61010 Anzahl je Verpackung: 1 Stücke |
auf Bestellung 1 Stücke: Lieferzeit 7-14 Tag (e) |
|
||||
BM157S Produktcode: 187137
zu Favoriten hinzufügen
Lieblingsprodukt
|
Werkzeuge und Geräte > Messgeräte |
Produkt ist nicht verfügbar
|