| Anzahl | Privatkunde |
|---|---|
| 1+ | 1284.22 EUR |
| 3+ | 1097.87 EUR |
| 5+ | 1040.68 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details F205 Ohmite
Category: Meters and AC/DC Clamp Probes, Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 34mm, Type of meter: multifunction, Measurement: AC current; active power; AC voltage; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance, Kind of display used: LCD, Display parameters: (5999), DC voltage measuring range: 150mV...1kV, DC voltage measuring accuracy: ±(1% + 3 digit), AC voltage measuring range: 150mV...1kV, AC voltage measuring accuracy: ±(1% + 3 digit), DC current measuring range: 150mA...900A, DC current measuring accuracy: ±(1% + 3 digit), AC current measuring range: 150mA...600A, AC current measuring accuracy: ±(1% + 3 digit), True effective value measurement: True RMS, Resistance measuring range: 0.1...59.99kΩ, Frequency measuring range: 5...20kHz, Frequency measuring accuracy: ±(0.4%+1 digit), Resistance measuring accuracy: ±(1%+5 digit), Continuity test: acoustic indication; 1Ω...599Ω, Power supply: battery 6LF22 9V x1, Standard equipment: case; crocodile clip x1; test leads; test probes, Conform to the norm: CAT IV 600V; EN 61010; EN 61243-3:2010, Measuring instrument features: automatic power-off; harmonics analyser; HOLD function; indicates phase sequence; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function, Battery/ rechargeable battery: battery 6LF22 9V x1, Illumination: yes, Test: diodes, Kind of meter: AC/DC pincers type; digital, Apparent power measurement: 1...600kVA, Max. diameter of measured cable: 34mm, Dimensions: 78x222x42mm, Reactive power measurement: 0.001...600kVAR.
Weitere Produktangebote F205
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Privatkunde |
|---|---|---|---|---|---|
|
F205 | CHAUVIN ARNOUX |
Category: Meters and AC/DC Clamp ProbesDescription: Meter: multifunction; digital,AC/DC pincers type; Øcable: 34mm Type of meter: multifunction Measurement: AC current; active power; AC voltage; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance Kind of display used: LCD Display parameters: (5999) DC voltage measuring range: 150mV...1kV DC voltage measuring accuracy: ±(1% + 3 digit) AC voltage measuring range: 150mV...1kV AC voltage measuring accuracy: ±(1% + 3 digit) DC current measuring range: 150mA...900A DC current measuring accuracy: ±(1% + 3 digit) AC current measuring range: 150mA...600A AC current measuring accuracy: ±(1% + 3 digit) True effective value measurement: True RMS Resistance measuring range: 0.1...59.99kΩ Frequency measuring range: 5...20kHz Frequency measuring accuracy: ±(0.4%+1 digit) Resistance measuring accuracy: ±(1%+5 digit) Continuity test: acoustic indication; 1Ω...599Ω Power supply: battery 6LF22 9V x1 Standard equipment: case; crocodile clip x1; test leads; test probes Conform to the norm: CAT IV 600V; EN 61010; EN 61243-3:2010 Measuring instrument features: automatic power-off; harmonics analyser; HOLD function; indicates phase sequence; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function Battery/ rechargeable battery: battery 6LF22 9V x1 Illumination: yes Test: diodes Kind of meter: AC/DC pincers type; digital Apparent power measurement: 1...600kVA Max. diameter of measured cable: 34mm Dimensions: 78x222x42mm Reactive power measurement: 0.001...600kVAR |
Produkt ist nicht verfügbar |
Im Einkaufswagen Stück im Wert von UAH |
| F205 |
![]() |
Hersteller: CHAUVIN ARNOUX
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 34mm
Type of meter: multifunction
Measurement: AC current; active power; AC voltage; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Kind of display used: LCD
Display parameters: (5999)
DC voltage measuring range: 150mV...1kV
DC voltage measuring accuracy: ±(1% + 3 digit)
AC voltage measuring range: 150mV...1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 150mA...900A
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring range: 150mA...600A
AC current measuring accuracy: ±(1% + 3 digit)
True effective value measurement: True RMS
Resistance measuring range: 0.1...59.99kΩ
Frequency measuring range: 5...20kHz
Frequency measuring accuracy: ±(0.4%+1 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication; 1Ω...599Ω
Power supply: battery 6LF22 9V x1
Standard equipment: case; crocodile clip x1; test leads; test probes
Conform to the norm: CAT IV 600V; EN 61010; EN 61243-3:2010
Measuring instrument features: automatic power-off; harmonics analyser; HOLD function; indicates phase sequence; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function
Battery/ rechargeable battery: battery 6LF22 9V x1
Illumination: yes
Test: diodes
Kind of meter: AC/DC pincers type; digital
Apparent power measurement: 1...600kVA
Max. diameter of measured cable: 34mm
Dimensions: 78x222x42mm
Reactive power measurement: 0.001...600kVAR
Category: Meters and AC/DC Clamp Probes
Description: Meter: multifunction; digital,AC/DC pincers type; Øcable: 34mm
Type of meter: multifunction
Measurement: AC current; active power; AC voltage; apparent power; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Kind of display used: LCD
Display parameters: (5999)
DC voltage measuring range: 150mV...1kV
DC voltage measuring accuracy: ±(1% + 3 digit)
AC voltage measuring range: 150mV...1kV
AC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring range: 150mA...900A
DC current measuring accuracy: ±(1% + 3 digit)
AC current measuring range: 150mA...600A
AC current measuring accuracy: ±(1% + 3 digit)
True effective value measurement: True RMS
Resistance measuring range: 0.1...59.99kΩ
Frequency measuring range: 5...20kHz
Frequency measuring accuracy: ±(0.4%+1 digit)
Resistance measuring accuracy: ±(1%+5 digit)
Continuity test: acoustic indication; 1Ω...599Ω
Power supply: battery 6LF22 9V x1
Standard equipment: case; crocodile clip x1; test leads; test probes
Conform to the norm: CAT IV 600V; EN 61010; EN 61243-3:2010
Measuring instrument features: automatic power-off; harmonics analyser; HOLD function; indicates phase sequence; low battery indicator; MIN/MAX function; PEAK function; REL function; selection of AC or AC+DC measurement; True InRush function
Battery/ rechargeable battery: battery 6LF22 9V x1
Illumination: yes
Test: diodes
Kind of meter: AC/DC pincers type; digital
Apparent power measurement: 1...600kVA
Max. diameter of measured cable: 34mm
Dimensions: 78x222x42mm
Reactive power measurement: 0.001...600kVAR
Produkt ist nicht verfügbar
Im Einkaufswagen
Stück im Wert von UAH