FG-R04-4AA KEMET
Hersteller: KEMET
Board Mount Current Sensors 250mV Max 4.5mA to 50mA 5 +/- 0.25V 13mA IMD -40 to +85C AEC-Q200
| Anzahl | Privatkunde |
|---|---|
| 1+ | 78.24 EUR |
| 5+ | 71.98 EUR |
| 10+ | 69.66 EUR |
| 25+ | 66.88 EUR |
| 50+ | 64.38 EUR |
| 100+ | 63.52 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FG-R04-4AA KEMET
Description: KEMET - FG-R04-4AA - Stromsensor, -50mA bis 50mA, Analog-/Digitalausgang, 1s, 4.75V bis 5.25V DC, Produktreihe FG-R04, tariffCode: 90303900, Ansprechzeit: 1s, euEccn: NLR, rohsCompliant: YES, Versorgungsspannung: 4.75V bis 5.25V, hazardous: false, rohsPhthalatesCompliant: YES, isCanonical: Y, Gemessener Strom: AC/DC, Betriebstemperatur, min.: -40°C, Sensormontage: Durchsteckmontage, Sensorausgang: Analog / Digital, Strommessbereich DC: -50mA bis 50mA, SVHC: No SVHC (04-Feb-2026), DC-Versorgungsspannung, max.: 5.25V, DC-Versorgungsspannung, min.: 4.75V, Produktpalette: FG Fluxgate-Based Residual Current Sensor, productTraceability: Yes-Date/Lot Code, Genauigkeit: -, usEccn: EAR99, Primärstrom: -50mA bis 50mA, Betriebstemperatur, max.: 105°C, Strommessbereich AC: -50mA bis 50mA, Stromsensortechnologie: Fluxgate / Magnetfelddetektor, Open-Loop.
Weitere Produktangebote FG-R04-4AA nach Preis ab 66.21 EUR bis 120.33 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Privatkunde | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FG-R04-4AA | KEMET |
Description: CURRENT SENSOR FLUX GATE/OL 50MAPackaging: Box Package / Case: Module Polarization: Bidirectional Sensitivity: 40V/A Mounting Type: Through Hole Output: Ratiometric, Voltage Frequency: DC ~ 55Hz Operating Temperature: -40°C ~ 105°C Voltage - Supply: 4.75V ~ 5.25V Response Time: 250ms (AC), 1s (DC) Sensor Type: Flux Gate, Open Loop For Measuring: AC/DC Current - Supply (Max): 13mA (Typ) Current - Sensing: 50mA Number of Channels: 1 |
auf Bestellung 95 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||||||||
|
FG-R04-4AA | KEMET |
Description: KEMET - FG-R04-4AA - Stromsensor, -50mA bis 50mA, Analog-/Digitalausgang, 1s, 4.75V bis 5.25V DC, Produktreihe FG-R04tariffCode: 90303900 Ansprechzeit: 1s euEccn: NLR rohsCompliant: YES Versorgungsspannung: 4.75V bis 5.25V hazardous: false rohsPhthalatesCompliant: YES isCanonical: Y Gemessener Strom: AC/DC Betriebstemperatur, min.: -40°C Sensormontage: Durchsteckmontage Sensorausgang: Analog / Digital Strommessbereich DC: -50mA bis 50mA SVHC: No SVHC (04-Feb-2026) DC-Versorgungsspannung, max.: 5.25V DC-Versorgungsspannung, min.: 4.75V Produktpalette: FG Fluxgate-Based Residual Current Sensor productTraceability: Yes-Date/Lot Code Genauigkeit: - usEccn: EAR99 Primärstrom: -50mA bis 50mA Betriebstemperatur, max.: 105°C Strommessbereich AC: -50mA bis 50mA Stromsensortechnologie: Fluxgate / Magnetfelddetektor, Open-Loop |
auf Bestellung 150 Stücke: Lieferzeit 14-21 Tag (e) |
|
| FG-R04-4AA |
![]() |
Hersteller: KEMET
Description: CURRENT SENSOR FLUX GATE/OL 50MA
Packaging: Box
Package / Case: Module
Polarization: Bidirectional
Sensitivity: 40V/A
Mounting Type: Through Hole
Output: Ratiometric, Voltage
Frequency: DC ~ 55Hz
Operating Temperature: -40°C ~ 105°C
Voltage - Supply: 4.75V ~ 5.25V
Response Time: 250ms (AC), 1s (DC)
Sensor Type: Flux Gate, Open Loop
For Measuring: AC/DC
Current - Supply (Max): 13mA (Typ)
Current - Sensing: 50mA
Number of Channels: 1
Description: CURRENT SENSOR FLUX GATE/OL 50MA
Packaging: Box
Package / Case: Module
Polarization: Bidirectional
Sensitivity: 40V/A
Mounting Type: Through Hole
Output: Ratiometric, Voltage
Frequency: DC ~ 55Hz
Operating Temperature: -40°C ~ 105°C
Voltage - Supply: 4.75V ~ 5.25V
Response Time: 250ms (AC), 1s (DC)
Sensor Type: Flux Gate, Open Loop
For Measuring: AC/DC
Current - Supply (Max): 13mA (Typ)
Current - Sensing: 50mA
Number of Channels: 1
auf Bestellung 95 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 1+ | 79.75 EUR |
| 5+ | 73.38 EUR |
| 10+ | 71 EUR |
| 25+ | 68.16 EUR |
| 50+ | 66.21 EUR |
| FG-R04-4AA |
![]() |
Hersteller: KEMET
Description: KEMET - FG-R04-4AA - Stromsensor, -50mA bis 50mA, Analog-/Digitalausgang, 1s, 4.75V bis 5.25V DC, Produktreihe FG-R04
tariffCode: 90303900
Ansprechzeit: 1s
euEccn: NLR
rohsCompliant: YES
Versorgungsspannung: 4.75V bis 5.25V
hazardous: false
rohsPhthalatesCompliant: YES
isCanonical: Y
Gemessener Strom: AC/DC
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Analog / Digital
Strommessbereich DC: -50mA bis 50mA
SVHC: No SVHC (04-Feb-2026)
DC-Versorgungsspannung, max.: 5.25V
DC-Versorgungsspannung, min.: 4.75V
Produktpalette: FG Fluxgate-Based Residual Current Sensor
productTraceability: Yes-Date/Lot Code
Genauigkeit: -
usEccn: EAR99
Primärstrom: -50mA bis 50mA
Betriebstemperatur, max.: 105°C
Strommessbereich AC: -50mA bis 50mA
Stromsensortechnologie: Fluxgate / Magnetfelddetektor, Open-Loop
Description: KEMET - FG-R04-4AA - Stromsensor, -50mA bis 50mA, Analog-/Digitalausgang, 1s, 4.75V bis 5.25V DC, Produktreihe FG-R04
tariffCode: 90303900
Ansprechzeit: 1s
euEccn: NLR
rohsCompliant: YES
Versorgungsspannung: 4.75V bis 5.25V
hazardous: false
rohsPhthalatesCompliant: YES
isCanonical: Y
Gemessener Strom: AC/DC
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Analog / Digital
Strommessbereich DC: -50mA bis 50mA
SVHC: No SVHC (04-Feb-2026)
DC-Versorgungsspannung, max.: 5.25V
DC-Versorgungsspannung, min.: 4.75V
Produktpalette: FG Fluxgate-Based Residual Current Sensor
productTraceability: Yes-Date/Lot Code
Genauigkeit: -
usEccn: EAR99
Primärstrom: -50mA bis 50mA
Betriebstemperatur, max.: 105°C
Strommessbereich AC: -50mA bis 50mA
Stromsensortechnologie: Fluxgate / Magnetfelddetektor, Open-Loop
auf Bestellung 150 Stücke:
Lieferzeit 14-21 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 3+ | 120.33 EUR |
| 5+ | 108.39 EUR |
| 10+ | 98.06 EUR |
| 25+ | 96.04 EUR |
| 50+ | 94.06 EUR |