FLUKE-561
Produktcode: 57672
zu Favoriten hinzufügen
Lieblingsprodukt
Hersteller:
Werkzeuge und Geräte > Messgeräte
Produktrezensionen
Produktbewertung abgeben
Weitere Produktangebote FLUKE-561 nach Preis ab 353.13 EUR bis 607.35 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Privatkunde | ||
|---|---|---|---|---|---|---|---|
|
FLUKE-561 | FLUKE |
Category: PirometersDescription: Infrared thermometer; LCD; -40÷550°C; Accur.(IR): ±1%,±1°C; ≤1.5m Measurement: non-contact temeprature (IR) Battery/ rechargeable battery: battery LR6 AA 1,5V x2 Measuring instrument features: 3 levels of emissivity adjustment; contact or non-contact temperature measurement; HOLD function; laser sight; low battery indicator; MIN/MAX/MEDIUM function; possibility of typical thermocouples connection Power supply: battery LR6 AA 1,5V x2 Response time: <0.5s Non-contact temperature measuring resolution: 0.1°C Standard equipment: case; test probe x1 Optional equipment: FLK-H6 - soft cover Emissivity value: 0,3 (fixed); 0,7 (fixed); 0,95 (fixed) Related items: FLK-80PK-11 Body dimensions: 177x163.5x52mm Kind of display used: LCD Temperature measuring accuracy (measurement with probe): ±1.1°C Temperature measuring range measured by probe: -30...150°C Optical resolution: 12:1 Non-contact temperature measuring range: -40...550°C Weight with battery: 340g Typical distance to measuring point: ≤1.5m Measuring unit: °C; °F Illumination: yes Type of meter: infrared thermometer Non-contact temperature measuring accuracy: ±1%; ±1°C |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE 561 | FLUKE |
Description: FLUKE - FLUKE 561 - IR- / Infrarot-Thermometer, HLK, -40°C bis +550°C, 1%, 0°C, 50°C, Produktreihe Fluke 560tariffCode: 90251900 Ansprechzeit: 500ms euEccn: NLR rohsCompliant: Y-EX Temperaturmessbereich: -40°C bis +550°C hazardous: false rohsPhthalatesCompliant: TBA isCanonical: Y Wellenlänge, max.: 670nm Verhältnis Abstand zu Messfleckdurchmesser: 12:1 Emissionsgrad: Drei Einstellungen: 0.3 / 0.7 / 0.95 Betriebstemperatur, min.: 0°C Batterie-/Akkugrößencode: 2 x AA SVHC: No SVHC (15-Jun-2015) Auflösung: 0.1 Produktpalette: 560 Series Laserklasse: Klasse 2 productTraceability: No usEccn: EAR99 Gewicht: 340g Betriebstemperatur, max.: 50°C Genauigkeit %: 1% Batterie-/Akkulebensdauer: 12h |
auf Bestellung 5 Stücke: Lieferzeit 14-21 Tag (e) |
|
||
|
FLUKE-561 | Fluke Electronics |
Description: THERMOMETER HVACPRO IRTemperature Display: C°/F° Probe Type: K Input Type: Infrared; Thermocouple Type: Handheld, Gun Temperature Range: -40 ~ 1022°F (-40 ~ 550°C) Display Type: LCD Battery Cell Size: AA (2) Features: Backlight, Hold, Laser Sight, Min/Max/Dif/KTC Packaging: Box |
auf Bestellung 219 Stücke: Lieferzeit 10-14 Tag (e) |
|
| FLUKE-561 |
![]() |
Hersteller: FLUKE
Category: Pirometers
Description: Infrared thermometer; LCD; -40÷550°C; Accur.(IR): ±1%,±1°C; ≤1.5m
Measurement: non-contact temeprature (IR)
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Measuring instrument features: 3 levels of emissivity adjustment; contact or non-contact temperature measurement; HOLD function; laser sight; low battery indicator; MIN/MAX/MEDIUM function; possibility of typical thermocouples connection
Power supply: battery LR6 AA 1,5V x2
Response time: <0.5s
Non-contact temperature measuring resolution: 0.1°C
Standard equipment: case; test probe x1
Optional equipment: FLK-H6 - soft cover
Emissivity value: 0,3 (fixed); 0,7 (fixed); 0,95 (fixed)
Related items: FLK-80PK-11
Body dimensions: 177x163.5x52mm
Kind of display used: LCD
Temperature measuring accuracy (measurement with probe): ±1.1°C
Temperature measuring range measured by probe: -30...150°C
Optical resolution: 12:1
Non-contact temperature measuring range: -40...550°C
Weight with battery: 340g
Typical distance to measuring point: ≤1.5m
Measuring unit: °C; °F
Illumination: yes
Type of meter: infrared thermometer
Non-contact temperature measuring accuracy: ±1%; ±1°C
Category: Pirometers
Description: Infrared thermometer; LCD; -40÷550°C; Accur.(IR): ±1%,±1°C; ≤1.5m
Measurement: non-contact temeprature (IR)
Battery/ rechargeable battery: battery LR6 AA 1,5V x2
Measuring instrument features: 3 levels of emissivity adjustment; contact or non-contact temperature measurement; HOLD function; laser sight; low battery indicator; MIN/MAX/MEDIUM function; possibility of typical thermocouples connection
Power supply: battery LR6 AA 1,5V x2
Response time: <0.5s
Non-contact temperature measuring resolution: 0.1°C
Standard equipment: case; test probe x1
Optional equipment: FLK-H6 - soft cover
Emissivity value: 0,3 (fixed); 0,7 (fixed); 0,95 (fixed)
Related items: FLK-80PK-11
Body dimensions: 177x163.5x52mm
Kind of display used: LCD
Temperature measuring accuracy (measurement with probe): ±1.1°C
Temperature measuring range measured by probe: -30...150°C
Optical resolution: 12:1
Non-contact temperature measuring range: -40...550°C
Weight with battery: 340g
Typical distance to measuring point: ≤1.5m
Measuring unit: °C; °F
Illumination: yes
Type of meter: infrared thermometer
Non-contact temperature measuring accuracy: ±1%; ±1°C
auf Bestellung 4 Stücke:
Lieferzeit 14-21 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 1+ | 353.13 EUR |
| FLUKE 561 |
![]() |
Hersteller: FLUKE
Description: FLUKE - FLUKE 561 - IR- / Infrarot-Thermometer, HLK, -40°C bis +550°C, 1%, 0°C, 50°C, Produktreihe Fluke 560
tariffCode: 90251900
Ansprechzeit: 500ms
euEccn: NLR
rohsCompliant: Y-EX
Temperaturmessbereich: -40°C bis +550°C
hazardous: false
rohsPhthalatesCompliant: TBA
isCanonical: Y
Wellenlänge, max.: 670nm
Verhältnis Abstand zu Messfleckdurchmesser: 12:1
Emissionsgrad: Drei Einstellungen: 0.3 / 0.7 / 0.95
Betriebstemperatur, min.: 0°C
Batterie-/Akkugrößencode: 2 x AA
SVHC: No SVHC (15-Jun-2015)
Auflösung: 0.1
Produktpalette: 560 Series
Laserklasse: Klasse 2
productTraceability: No
usEccn: EAR99
Gewicht: 340g
Betriebstemperatur, max.: 50°C
Genauigkeit %: 1%
Batterie-/Akkulebensdauer: 12h
Description: FLUKE - FLUKE 561 - IR- / Infrarot-Thermometer, HLK, -40°C bis +550°C, 1%, 0°C, 50°C, Produktreihe Fluke 560
tariffCode: 90251900
Ansprechzeit: 500ms
euEccn: NLR
rohsCompliant: Y-EX
Temperaturmessbereich: -40°C bis +550°C
hazardous: false
rohsPhthalatesCompliant: TBA
isCanonical: Y
Wellenlänge, max.: 670nm
Verhältnis Abstand zu Messfleckdurchmesser: 12:1
Emissionsgrad: Drei Einstellungen: 0.3 / 0.7 / 0.95
Betriebstemperatur, min.: 0°C
Batterie-/Akkugrößencode: 2 x AA
SVHC: No SVHC (15-Jun-2015)
Auflösung: 0.1
Produktpalette: 560 Series
Laserklasse: Klasse 2
productTraceability: No
usEccn: EAR99
Gewicht: 340g
Betriebstemperatur, max.: 50°C
Genauigkeit %: 1%
Batterie-/Akkulebensdauer: 12h
auf Bestellung 5 Stücke:
Lieferzeit 14-21 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 1+ | 597.26 EUR |
| FLUKE-561 |
![]() |
Hersteller: Fluke Electronics
Description: THERMOMETER HVACPRO IR
Temperature Display: C°/F°
Probe Type: K
Input Type: Infrared; Thermocouple
Type: Handheld, Gun
Temperature Range: -40 ~ 1022°F (-40 ~ 550°C)
Display Type: LCD
Battery Cell Size: AA (2)
Features: Backlight, Hold, Laser Sight, Min/Max/Dif/KTC
Packaging: Box
Description: THERMOMETER HVACPRO IR
Temperature Display: C°/F°
Probe Type: K
Input Type: Infrared; Thermocouple
Type: Handheld, Gun
Temperature Range: -40 ~ 1022°F (-40 ~ 550°C)
Display Type: LCD
Battery Cell Size: AA (2)
Features: Backlight, Hold, Laser Sight, Min/Max/Dif/KTC
Packaging: Box
auf Bestellung 219 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Privatkunde |
|---|---|
| 1+ | 607.35 EUR |




