Hersteller: FLUKECategory: Calibrators
Description: Meter: multimeter calibrator; Diode test: 0.3mA@600mV
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010
Continuity test: acoustic indication; <100Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Power supply: battery LR6 AA 1,5V x4
Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71
Software: Fluke Connect (FLK-IR3000FC)
Type of meter: multimeter calibrator
Related items: POM-5900A/POM; POM-6173A; POM-7519A
Kind of display used: LCD
AC current measuring range: 0.001mA...1A
DC current measuring range: 1µA...30mA; 1A
DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV
AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV
Diode test: 0.3mA @600mV
Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
DC voltage measuring accuracy: ±(0.1% + 1 digit)
Resistance measuring accuracy: ±(0.2%+1 digit)
DC current measuring accuracy: ±(0.2% + 2 digit)
Dimensions: 203x100x50mm
AC voltage measuring accuracy: ±(0.7% + 2 digit)
AC current measuring accuracy: ±(1% + 2 digit)
Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate
Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set
Anzahl je Verpackung: 1 Stücke
auf Bestellung 1 Stücke:
Lieferzeit 7-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 1+ | 1904.69 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE-787B FLUKE
Description: FLUKE - FLUKE 787B - Digitalmultimeter, ProcessMeter, 4000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.75-stellig, tariffCode: 90303100, Messwert Gleichspannung, max.: 1kV, Messwert Wechselspannung, max.: 1kV, Messwert Widerstand, max.: 40Mohm, Messwert Gleichstrom, max.: 1A, rohsCompliant: Y-EX, hazardous: false, rohsPhthalatesCompliant: TBA, usEccn: 3A992.a, Schritte: 4000, Herstellergewährleistung: 3 Jahre, euEccn: NLR, Anzahl der Stellen: 3.75, DMM-Messverfahren: Echteffektivwert, DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Durchgang, Diode, Frequenz, Widerstand, Temperatur, Produktpalette: -, productTraceability: No, Messwert Wechselstrom, max.: 1A, Bereichswahl: Automatisch, manuell, SVHC: No SVHC (15-Jan-2018).
Weitere Produktangebote FLUKE-787B nach Preis ab 1904.69 EUR bis 2113.76 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
|---|---|---|---|---|---|---|---|---|---|
![]() +5 |
FLUKE-787B | Hersteller : FLUKE |
Category: CalibratorsDescription: Meter: multimeter calibrator; Diode test: 0.3mA@600mV Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010; EN 61243-3:2010 Continuity test: acoustic indication; <100Ω Battery/ rechargeable battery: battery LR6 AA 1,5V x4 Power supply: battery LR6 AA 1,5V x4 Standard equipment: crocodile clips FLK-AC72; test leads FLK-TL71 Software: Fluke Connect (FLK-IR3000FC) Type of meter: multimeter calibrator Related items: POM-5900A/POM; POM-6173A; POM-7519A Kind of display used: LCD AC current measuring range: 0.001mA...1A DC current measuring range: 1µA...30mA; 1A DC voltage measuring range: 1...400mV; 4V; 40V; 400V; 1kV AC voltage measuring range: 0.1...400mV; 4V; 40V; 400V; 1kV Diode test: 0.3mA @600mV Resistance measuring range: 100mΩ...400Ω; 4kΩ; 400kΩ; 4MΩ; 40MΩ Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) DC voltage measuring accuracy: ±(0.1% + 1 digit) Resistance measuring accuracy: ±(0.2%+1 digit) DC current measuring accuracy: ±(0.2% + 2 digit) Dimensions: 203x100x50mm AC voltage measuring accuracy: ±(0.7% + 2 digit) AC current measuring accuracy: ±(1% + 2 digit) Measuring instrument features: automatic and manual setting of step function; HOLD function; MIN/MAX/MEAN/REL function; simultaneous readout in mA and % of range; source DC current / calibrate loop current, source/simulate Optional equipment: 240A AC/DC FLK-I200S current clamp probe; 400A AC/DC FLK-I410 current clamp probe; crocodile clip FLK-AC89; crocodile clip FLK-AC220; crocodile clip FLK-AC283; crocodile clip FLK-AC285; FLK-C510 - soft cover; FLK-FVF-SC2 software; FLK-TL225 set |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
|
FLUKE-787B | Hersteller : Fluke Electronics |
Description: PROCESS METERFeatures: Min/Max/Ave Packaging: Bulk Display Type: LCD, Dual Style: Handheld Function: Voltage, Current, Resistance, Frequency Type: Digital (DMM) Ranging: Auto/Manual Display Count: 4000 Functions, Extra: Battery Test, Diode Test Response: True RMS Part Status: Active Display Digits: 3.75 |
auf Bestellung 8 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||
|
FLUKE 787B | Hersteller : FLUKE |
Description: FLUKE - FLUKE 787B - Digitalmultimeter, ProcessMeter, 4000 Zählwerte, TRMS, autom./manuelle Bereichswahl, 3.75-stelligtariffCode: 90303100 Messwert Gleichspannung, max.: 1kV Messwert Wechselspannung, max.: 1kV Messwert Widerstand, max.: 40Mohm Messwert Gleichstrom, max.: 1A rohsCompliant: Y-EX hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Schritte: 4000 Herstellergewährleistung: 3 Jahre euEccn: NLR Anzahl der Stellen: 3.75 DMM-Messverfahren: Echteffektivwert DMM-Funktionen: AC/DC-Strom, AC/DC-Spannung, Durchgang, Diode, Frequenz, Widerstand, Temperatur Produktpalette: - productTraceability: No Messwert Wechselstrom, max.: 1A Bereichswahl: Automatisch, manuell SVHC: No SVHC (15-Jan-2018) |