FLUKE-87V-MAX/E2 KIT

Category: Portable digital multimeters
Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s
Type of meter: digital multimeter
Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature
Kind of display used: LCD
Display parameters: (6000/20000)
DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
DC voltage measuring accuracy: ±(0.05% + 1 digit)
AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV
AC voltage measuring accuracy: ±(0.7% + 4 digit)
DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s
DC current measuring accuracy: ±(0.2% + 4 digit)
AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s)
AC current measuring accuracy: ±(1% + 2 digit)
True effective value measurement: True RMS AC
Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ
Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF
Capacitance measuring accuracy: ±(1%+ 2 digit)
Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz
Frequency measuring accuracy: ±(0.005%+1 digit)
Temperature measuring range: -200...1090°C
Resistance measuring accuracy: ±(0.2%+1 digit)
Diode test: 1mA @3V
Continuity test: acoustic indication
Power supply: battery LR6 AA 1,5V x3
Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238
Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010
Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B
Dimensions (W x H x D): 63x198x100mm
Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation
Battery/ rechargeable battery: battery LR6 AA 1,5V x3
Illumination: yes
Temperature measurement resolution: 0.1°C
Temperature measurement accuracy: ±(1% + 10 digit)
Conductance measuring accuracy: ±(1% + 10digit)
Pollution degree: 2
Weight with battery: 700g
Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter
IP rating: IP67
Bargraph: 33 segm. 40x/s
Conductance measurement: 0.01...60nS
Anzahl je Verpackung: 1 Stücke
auf Bestellung 3 Stücke:
Lieferzeit 7-14 Tag (e)
Anzahl | Preis |
---|---|
1+ | 1140.63 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details FLUKE-87V-MAX/E2 KIT FLUKE
Category: Portable digital multimeters, Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s, Type of meter: digital multimeter, Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature, Kind of display used: LCD, Display parameters: (6000/20000), DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, DC voltage measuring accuracy: ±(0.05% + 1 digit), AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV, AC voltage measuring accuracy: ±(0.7% + 4 digit), DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s, DC current measuring accuracy: ±(0.2% + 4 digit), AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A .
Weitere Produktangebote FLUKE-87V-MAX/E2 KIT nach Preis ab 1140.63 EUR bis 1660.21 EUR
Foto | Bezeichnung | Hersteller | Beschreibung |
Verfügbarkeit |
Preis | ||||
---|---|---|---|---|---|---|---|---|---|
![]() +3 |
FLUKE-87V-MAX/E2 KIT | Hersteller : FLUKE |
![]() Description: Digital multimeter; LCD; (6000/20000); Bargraph: 33segm.40x/s Type of meter: digital multimeter Measurement: AC current; AC voltage; capacitance; DC current; DC voltage; frequency; resistance; temperature Kind of display used: LCD Display parameters: (6000/20000) DC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV DC voltage measuring accuracy: ±(0.05% + 1 digit) AC voltage measuring range: 0.1...600mV; 6V; 60V; 600V; 1kV AC voltage measuring accuracy: ±(0.7% + 4 digit) DC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; 20A < 30s DC current measuring accuracy: ±(0.2% + 4 digit) AC current measuring range: 0.1...600µA; 6mA; 60mA; 400mA; 6A; 10A; (20A <30s) AC current measuring accuracy: ±(1% + 2 digit) True effective value measurement: True RMS AC Resistance measuring range: 100mΩ...600Ω; 6kΩ; 60kΩ; 600kΩ; 6MΩ; 50MΩ Capacitance measuring range: 10pF...10nF; 100nF; 1µF; 10µF; 100µF; 9.999mF Capacitance measuring accuracy: ±(1%+ 2 digit) Frequency measuring range: 10mHz...199.99Hz; 1999.9Hz; 19.999kHz; 199.99kHz Frequency measuring accuracy: ±(0.005%+1 digit) Temperature measuring range: -200...1090°C Resistance measuring accuracy: ±(0.2%+1 digit) Diode test: 1mA @3V Continuity test: acoustic indication Power supply: battery LR6 AA 1,5V x3 Standard equipment: crocodile clip FLK-AC220 x2; FLK-80BK-A drop-like K-type probe; FLK-C35 soft cover; magnetic hanging strap FLK-TOOLPAK; test leads FLK-TL-224; test probes FLK-TL238 Conform to the norm: CAT III 1000V; CAT IV 600V; EN 61010 Related items: FLK-80BK-A; FLK-80PJ-1; FLK-80PJ-9; FLK-80PJ-EXT; FLK-80PK-1; FLK-80PK-3A; FLK-80PK-8; FLK-80PK-9; FLK-80PK-11; FLK-80PK-22; FLK-80PK-24; FLK-80PK-25; FLK-80PK-26; FLK-80PK-27; FLK-80PR-60; FLK-80PT-EXT; FLK-80T-150UA; POM-4408; POM-5519A; POM-5673B Dimensions (W x H x D): 63x198x100mm Measuring instrument features: auto and manual ranging; automatic power-off; built-in thermometer; filter ensuring voltage and frequency measuring accuracy; HOLD function; impact resistant holster; indicates incorrect connection of test leads; MIN/MAX/MEDIUM function; PEAK HOLD function; test leads resistance compensation Battery/ rechargeable battery: battery LR6 AA 1,5V x3 Illumination: yes Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±(1% + 10 digit) Conductance measuring accuracy: ±(1% + 10digit) Pollution degree: 2 Weight with battery: 700g Optional equipment: 400A AC/DC FLK-I410 current clamp probe; FLK-C25 soft cover; FLK-TL238 set; FLK-TOOLPAK strap with magnet for suspending the meter IP rating: IP67 Bargraph: 33 segm. 40x/s Conductance measurement: 0.01...60nS |
auf Bestellung 3 Stücke: Lieferzeit 14-21 Tag (e) |
|
||||
![]() |
FLUKE-87V-MAX/E2 KIT | Hersteller : Fluke Electronics |
Description: INDUSTRIAL TRUE RMS HEAVY DUTY M Features: Backlight, Hold Packaging: Bulk Display Type: LCD Style: Handheld Function: Capacitance, Current, Frequency, Resistance, Temperature, Voltage Type: Digital (DMM) Ranging: Auto Ratings: CAT IV 600V, CAT III 1000V Display Count: 19999 Functions, Extra: Continuity Test, Diode Test Response: True RMS Part Status: Active Display Digits: 5 |
auf Bestellung 1 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||
![]() |
FLUKE-87V-MAX/E2 KIT | Hersteller : FLUKE |
Description: FLUKE - FLUKE-87V-MAX/E2 KIT - Industrielles Digitalmultimeter im Kit, Echteffektiv (TRMS), 1kV AC/DC, IP67 tariffCode: 90308900 productTraceability: No rohsCompliant: Y-EX Lieferumfang des Kits: DMM 87V MAX, Messleitungen TL224, Krokodilklemmen AC220, Messfühler TL238/80BK-A, magnetische Aufhängevorrichtung, Tasche/AA-Batterien euEccn: NLR hazardous: false rohsPhthalatesCompliant: TBA usEccn: 3A992.a Produktpalette: - SVHC: No SVHC (15-Jun-2015) |
auf Bestellung 4 Stücke: Lieferzeit 14-21 Tag (e) |
|||||
FLUKE-87V-MAX/E2-KIT | Hersteller : Fluke | FLUKE-87V-MAX/E2-KIT |
auf Bestellung 1 Stücke: Lieferzeit 14-21 Tag (e) |
|
|||||
![]() |
FLUKE-87V-MAX/E2 KIT | Hersteller : Fluke |
![]() |
Produkt ist nicht verfügbar |