LA 200-P LEM
Hersteller: LEM
Board Mount Current Sensors Current Transducer LA 200-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
| Anzahl | Preis |
|---|---|
| 1+ | 75.94 EUR |
| 5+ | 69.89 EUR |
| 10+ | 65.1 EUR |
| 24+ | 61.42 EUR |
| 48+ | 58.64 EUR |
| 120+ | 57.55 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details LA 200-P LEM
Description: LEM - LA 200-P - Stromwandler, Hall-Effekt, Closed-Loop, AC/DC/gepulst, 200A, analog - 100mA, ±12V bis 15V Versorgung, tariffCode: 85437090, rohsCompliant: YES, Versorgungsspannung: ± 12V bis 15V, hazardous: false, rohsPhthalatesCompliant: YES, Sekundärsignal: 100mA, isCanonical: Y, Gemessener Strom: AC / DC / gepulst, usEccn: EAR99, Betriebstemperatur, min.: -40°C, Sensormontage: Durchsteckmontage, Sensorausgang: Analog, euEccn: NLR, Produktpalette: LA200 Series, productTraceability: No, Genauigkeit: ±0.4%, Primärstrom: 200A, Betriebstemperatur, max.: 85°C, Stromsensortechnologie: Hall-Effekt, Closed-Loop, SVHC: No SVHC (25-Jun-2025).
Weitere Produktangebote LA 200-P nach Preis ab 61.86 EUR bis 77.02 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Preis |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
LA 200-P | LEM USA Inc. |
Description: CURRENT SENSOR HE/CL 200APackaging: Bulk Package / Case: Module Polarization: Bidirectional Mounting Type: Through Hole Output: Ratiometric, Current Frequency: DC ~ 100kHz Accuracy: ±0.40% Operating Temperature: -40°C ~ 85°C Voltage - Supply: ±12V ~ 15V Response Time: 1µs Sensor Type: Hall Effect, Closed Loop Linearity: ±0.15% For Measuring: AC/DC Current - Supply (Max): 16mA Current - Sensing: 200A Number of Channels: 1 |
auf Bestellung 710 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||||||||||
|
LA 200-P | LEM |
Description: LEM - LA 200-P - Stromwandler, Hall-Effekt, Closed-Loop, AC/DC/gepulst, 200A, analog - 100mA, ±12V bis 15V VersorgungtariffCode: 85437090 rohsCompliant: YES Versorgungsspannung: ± 12V bis 15V hazardous: false rohsPhthalatesCompliant: YES Sekundärsignal: 100mA isCanonical: Y Gemessener Strom: AC / DC / gepulst usEccn: EAR99 Betriebstemperatur, min.: -40°C Sensormontage: Durchsteckmontage Sensorausgang: Analog euEccn: NLR Produktpalette: LA200 Series productTraceability: No Genauigkeit: ±0.4% Primärstrom: 200A Betriebstemperatur, max.: 85°C Stromsensortechnologie: Hall-Effekt, Closed-Loop SVHC: No SVHC (25-Jun-2025) |
auf Bestellung 88 Stücke: Lieferzeit 14-21 Tag (e) |
Im Einkaufswagen Stück im Wert von UAH |
| LA 200-P |
![]() |
Hersteller: LEM USA Inc.
Description: CURRENT SENSOR HE/CL 200A
Packaging: Bulk
Package / Case: Module
Polarization: Bidirectional
Mounting Type: Through Hole
Output: Ratiometric, Current
Frequency: DC ~ 100kHz
Accuracy: ±0.40%
Operating Temperature: -40°C ~ 85°C
Voltage - Supply: ±12V ~ 15V
Response Time: 1µs
Sensor Type: Hall Effect, Closed Loop
Linearity: ±0.15%
For Measuring: AC/DC
Current - Supply (Max): 16mA
Current - Sensing: 200A
Number of Channels: 1
Description: CURRENT SENSOR HE/CL 200A
Packaging: Bulk
Package / Case: Module
Polarization: Bidirectional
Mounting Type: Through Hole
Output: Ratiometric, Current
Frequency: DC ~ 100kHz
Accuracy: ±0.40%
Operating Temperature: -40°C ~ 85°C
Voltage - Supply: ±12V ~ 15V
Response Time: 1µs
Sensor Type: Hall Effect, Closed Loop
Linearity: ±0.15%
For Measuring: AC/DC
Current - Supply (Max): 16mA
Current - Sensing: 200A
Number of Channels: 1
auf Bestellung 710 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 1+ | 77.02 EUR |
| 5+ | 70.86 EUR |
| 24+ | 65.97 EUR |
| 48+ | 64.1 EUR |
| 72+ | 63.08 EUR |
| 120+ | 61.86 EUR |
| LA 200-P |
![]() |
Hersteller: LEM
Description: LEM - LA 200-P - Stromwandler, Hall-Effekt, Closed-Loop, AC/DC/gepulst, 200A, analog - 100mA, ±12V bis 15V Versorgung
tariffCode: 85437090
rohsCompliant: YES
Versorgungsspannung: ± 12V bis 15V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 100mA
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
usEccn: EAR99
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Analog
euEccn: NLR
Produktpalette: LA200 Series
productTraceability: No
Genauigkeit: ±0.4%
Primärstrom: 200A
Betriebstemperatur, max.: 85°C
Stromsensortechnologie: Hall-Effekt, Closed-Loop
SVHC: No SVHC (25-Jun-2025)
Description: LEM - LA 200-P - Stromwandler, Hall-Effekt, Closed-Loop, AC/DC/gepulst, 200A, analog - 100mA, ±12V bis 15V Versorgung
tariffCode: 85437090
rohsCompliant: YES
Versorgungsspannung: ± 12V bis 15V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 100mA
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
usEccn: EAR99
Betriebstemperatur, min.: -40°C
Sensormontage: Durchsteckmontage
Sensorausgang: Analog
euEccn: NLR
Produktpalette: LA200 Series
productTraceability: No
Genauigkeit: ±0.4%
Primärstrom: 200A
Betriebstemperatur, max.: 85°C
Stromsensortechnologie: Hall-Effekt, Closed-Loop
SVHC: No SVHC (25-Jun-2025)
auf Bestellung 88 Stücke:
Lieferzeit 14-21 Tag (e)