LF 310-S LEM
Hersteller: LEM
Current Sensors – Industrial Current Transducer LF 310-S. For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
| Anzahl | Preis |
|---|---|
| 1+ | 133.04 EUR |
| 5+ | 123.24 EUR |
| 10+ | 119.63 EUR |
| 60+ | 119.5 EUR |
Produktrezensionen
Produktbewertung abgeben
Technische Details LF 310-S LEM
Description: LEM - LF 310-S - Stromwandler, Produktreihe LF, 300A, -500A bis 500A, 0.2%, Closed-Loop-Ausgang, 12V DC bis 20V DC, tariffCode: 90303370, Ansprechzeit: 500ns, rohsCompliant: YES, Versorgungsspannung: ±11.4V bis ±21V, hazardous: false, rohsPhthalatesCompliant: YES, Sekundärsignal: 150mA, isCanonical: Y, Gemessener Strom: AC / DC / gepulst, usEccn: EAR99, Betriebstemperatur, min.: -40°C, Sensormontage: Panelmontage, Sensorausgang: Strom, euEccn: NLR, Strommessbereich DC: -500A bis 500A, DC-Versorgungsspannung, max.: 21V, DC-Versorgungsspannung, min.: -11.4V, Produktpalette: LF310 Series, productTraceability: No, Genauigkeit: ±0.2%, Primärstrom: 300A, Betriebstemperatur, max.: 85°C, Genauigkeit %: 0.2%, Strommessbereich AC: -500A bis 500A, Stromsensortechnologie: Hall-Effekt, Closed-Loop, SVHC: No SVHC (25-Jun-2025).
Weitere Produktangebote LF 310-S nach Preis ab 112.13 EUR bis 136.82 EUR
| Foto | Bezeichnung | Hersteller | Beschreibung | Verfügbarkeit | Preis |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
LF 310-S | LEM USA Inc. |
Description: CURRENT SENSOR HE/CL 300ANumber of Channels: 1 Part Status: Active Current - Sensing: 300A Current - Supply (Max): 38mA For Measuring: AC/DC Linearity: ±0.05% Sensor Type: Hall Effect, Closed Loop Response Time: 0.5µs Voltage - Supply: 11.4V ~ 21V Operating Temperature: -40°C ~ 85°C Accuracy: ±0.2% Frequency: 100kHz Output: Ratiometric, Current Mounting Type: Panel Mount Sensitivity: 0.5mA/A Polarization: Bidirectional Package / Case: Module, Single Pass Through Packaging: Bulk |
auf Bestellung 134 Stücke: Lieferzeit 10-14 Tag (e) |
|
||||||||||||
|
LF 310-S | LEM |
Description: LEM - LF 310-S - Stromwandler, Produktreihe LF, 300A, -500A bis 500A, 0.2%, Closed-Loop-Ausgang, 12V DC bis 20V DCtariffCode: 90303370 Ansprechzeit: 500ns rohsCompliant: YES Versorgungsspannung: ±11.4V bis ±21V hazardous: false rohsPhthalatesCompliant: YES Sekundärsignal: 150mA isCanonical: Y Gemessener Strom: AC / DC / gepulst usEccn: EAR99 Betriebstemperatur, min.: -40°C Sensormontage: Panelmontage Sensorausgang: Strom euEccn: NLR Strommessbereich DC: -500A bis 500A DC-Versorgungsspannung, max.: 21V DC-Versorgungsspannung, min.: -11.4V Produktpalette: LF310 Series productTraceability: No Genauigkeit: ±0.2% Primärstrom: 300A Betriebstemperatur, max.: 85°C Genauigkeit %: 0.2% Strommessbereich AC: -500A bis 500A Stromsensortechnologie: Hall-Effekt, Closed-Loop SVHC: No SVHC (25-Jun-2025) |
auf Bestellung 578 Stücke: Lieferzeit 14-21 Tag (e) |
Im Einkaufswagen Stück im Wert von UAH |
| LF 310-S |
![]() |
Hersteller: LEM USA Inc.
Description: CURRENT SENSOR HE/CL 300A
Number of Channels: 1
Part Status: Active
Current - Sensing: 300A
Current - Supply (Max): 38mA
For Measuring: AC/DC
Linearity: ±0.05%
Sensor Type: Hall Effect, Closed Loop
Response Time: 0.5µs
Voltage - Supply: 11.4V ~ 21V
Operating Temperature: -40°C ~ 85°C
Accuracy: ±0.2%
Frequency: 100kHz
Output: Ratiometric, Current
Mounting Type: Panel Mount
Sensitivity: 0.5mA/A
Polarization: Bidirectional
Package / Case: Module, Single Pass Through
Packaging: Bulk
Description: CURRENT SENSOR HE/CL 300A
Number of Channels: 1
Part Status: Active
Current - Sensing: 300A
Current - Supply (Max): 38mA
For Measuring: AC/DC
Linearity: ±0.05%
Sensor Type: Hall Effect, Closed Loop
Response Time: 0.5µs
Voltage - Supply: 11.4V ~ 21V
Operating Temperature: -40°C ~ 85°C
Accuracy: ±0.2%
Frequency: 100kHz
Output: Ratiometric, Current
Mounting Type: Panel Mount
Sensitivity: 0.5mA/A
Polarization: Bidirectional
Package / Case: Module, Single Pass Through
Packaging: Bulk
auf Bestellung 134 Stücke:
Lieferzeit 10-14 Tag (e)
| Anzahl | Preis |
|---|---|
| 1+ | 136.82 EUR |
| 5+ | 126.78 EUR |
| 10+ | 123.05 EUR |
| 25+ | 118.62 EUR |
| 60+ | 114.84 EUR |
| 120+ | 112.13 EUR |
| LF 310-S |
![]() |
Hersteller: LEM
Description: LEM - LF 310-S - Stromwandler, Produktreihe LF, 300A, -500A bis 500A, 0.2%, Closed-Loop-Ausgang, 12V DC bis 20V DC
tariffCode: 90303370
Ansprechzeit: 500ns
rohsCompliant: YES
Versorgungsspannung: ±11.4V bis ±21V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 150mA
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
usEccn: EAR99
Betriebstemperatur, min.: -40°C
Sensormontage: Panelmontage
Sensorausgang: Strom
euEccn: NLR
Strommessbereich DC: -500A bis 500A
DC-Versorgungsspannung, max.: 21V
DC-Versorgungsspannung, min.: -11.4V
Produktpalette: LF310 Series
productTraceability: No
Genauigkeit: ±0.2%
Primärstrom: 300A
Betriebstemperatur, max.: 85°C
Genauigkeit %: 0.2%
Strommessbereich AC: -500A bis 500A
Stromsensortechnologie: Hall-Effekt, Closed-Loop
SVHC: No SVHC (25-Jun-2025)
Description: LEM - LF 310-S - Stromwandler, Produktreihe LF, 300A, -500A bis 500A, 0.2%, Closed-Loop-Ausgang, 12V DC bis 20V DC
tariffCode: 90303370
Ansprechzeit: 500ns
rohsCompliant: YES
Versorgungsspannung: ±11.4V bis ±21V
hazardous: false
rohsPhthalatesCompliant: YES
Sekundärsignal: 150mA
isCanonical: Y
Gemessener Strom: AC / DC / gepulst
usEccn: EAR99
Betriebstemperatur, min.: -40°C
Sensormontage: Panelmontage
Sensorausgang: Strom
euEccn: NLR
Strommessbereich DC: -500A bis 500A
DC-Versorgungsspannung, max.: 21V
DC-Versorgungsspannung, min.: -11.4V
Produktpalette: LF310 Series
productTraceability: No
Genauigkeit: ±0.2%
Primärstrom: 300A
Betriebstemperatur, max.: 85°C
Genauigkeit %: 0.2%
Strommessbereich AC: -500A bis 500A
Stromsensortechnologie: Hall-Effekt, Closed-Loop
SVHC: No SVHC (25-Jun-2025)
auf Bestellung 578 Stücke:
Lieferzeit 14-21 Tag (e)


