M74 MACOM Technology Solutions


M74_M74C.pdf
Hersteller: MACOM Technology Solutions
Description: MIXER,MICROWAVE
Packaging: Tray
Package / Case: Module
Frequency: 7MHz ~ 18GHz
RF Type: General Purpose
Secondary Attributes: Down Converter
Noise Figure: 7dB
Number of Mixers: 2
Part Status: Active
auf Bestellung 44 Stücke:
Lieferzeit 10-14 Tag (e)
AnzahlPrivatkunde
1+1020.02 EUR
Im Einkaufswagen  Stück im Wert von  UAH
Artikel auf Bestellung
Nicht an unserem Lager — wir beziehen ihn nach Ihrer Bestellung vom Lieferantenlager.
Lieferzeit: 10-14 Tag (e)
Produktrezensionen
Produktbewertung abgeben

Technische Details M74 MACOM Technology Solutions

Category: Multimeters for Electrical Installations, Description: Meter: appliance meter; LCD; Earthing R range: 1÷1999Ω; 30÷400Hz, Earthing resistance measuring range: 1...1999Ω, Battery/ rechargeable battery: battery LR6 AA 1,5V x4, Measuring instrument features: automatic test mode; HOLD function; MIN/MAX/AVG function, Power supply: battery LR6 AA 1,5V x4, DC voltage measuring accuracy: ±(0.5% + 2 digit), Standard equipment: 2 crocodile clips; calibration certificate; case; test leads ( 2pcs.); test mains cable, Body dimensions: 240x100x45mm, Kind of display used: LCD, Continuity test: acoustic indication; optical indication; 10mΩ...99.9Ω, True effective value measurement: True RMS, DC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V, Frequency measuring range: 30...400Hz, AC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V, RCD test: AC, A-type RCDs, Resistance measuring range: 39.99Ω; 399.9Ω; 3999Ω; 39.99kΩ, Insulation resistance measuring ranges: 19.99MΩ; 199.9MΩ; 999MΩ, Frequency measuring accuracy: ±(0.5%+2 digit), Insulation resistance measuring accuracy: ±(5% + 2digit), Test voltage: 250V; 500V, Conform to the norm: CAT III 550V; EN 61557-1, Resistance measuring accuracy: ±(1%+5 digit), AC voltage measuring accuracy: ±(2% + 2 digit), Type of meter: appliance meter, Measurement: AC current; AC voltage; continuity; DC current; DC voltage; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance.

Weitere Produktangebote M74

Foto Bezeichnung Hersteller Beschreibung Verfügbarkeit Privatkunde
M74 M74 HT INSTRUMENTS HTI-HV000074.pdf Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 1÷1999Ω; 30÷400Hz
Earthing resistance measuring range: 1...1999Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Measuring instrument features: automatic test mode; HOLD function; MIN/MAX/AVG function
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Standard equipment: 2 crocodile clips; calibration certificate; case; test leads ( 2pcs.); test mains cable
Body dimensions: 240x100x45mm
Kind of display used: LCD
Continuity test: acoustic indication; optical indication; 10mΩ...99.9Ω
True effective value measurement: True RMS
DC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V
Frequency measuring range: 30...400Hz
AC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V
RCD test: AC, A-type RCDs
Resistance measuring range: 39.99Ω; 399.9Ω; 3999Ω; 39.99kΩ
Insulation resistance measuring ranges: 19.99MΩ; 199.9MΩ; 999MΩ
Frequency measuring accuracy: ±(0.5%+2 digit)
Insulation resistance measuring accuracy: ±(5% + 2digit)
Test voltage: 250V; 500V
Conform to the norm: CAT III 550V; EN 61557-1
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(2% + 2 digit)
Type of meter: appliance meter
Measurement: AC current; AC voltage; continuity; DC current; DC voltage; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)
Im Einkaufswagen  Stück im Wert von  UAH
M74 HTI-HV000074.pdf
Hersteller: HT INSTRUMENTS
Category: Multimeters for Electrical Installations
Description: Meter: appliance meter; LCD; Earthing R range: 1÷1999Ω; 30÷400Hz
Earthing resistance measuring range: 1...1999Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Measuring instrument features: automatic test mode; HOLD function; MIN/MAX/AVG function
Power supply: battery LR6 AA 1,5V x4
DC voltage measuring accuracy: ±(0.5% + 2 digit)
Standard equipment: 2 crocodile clips; calibration certificate; case; test leads ( 2pcs.); test mains cable
Body dimensions: 240x100x45mm
Kind of display used: LCD
Continuity test: acoustic indication; optical indication; 10mΩ...99.9Ω
True effective value measurement: True RMS
DC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V
Frequency measuring range: 30...400Hz
AC voltage measuring range: 999.9mV; 9.999V; 99.99V; 605V
RCD test: AC, A-type RCDs
Resistance measuring range: 39.99Ω; 399.9Ω; 3999Ω; 39.99kΩ
Insulation resistance measuring ranges: 19.99MΩ; 199.9MΩ; 999MΩ
Frequency measuring accuracy: ±(0.5%+2 digit)
Insulation resistance measuring accuracy: ±(5% + 2digit)
Test voltage: 250V; 500V
Conform to the norm: CAT III 550V; EN 61557-1
Resistance measuring accuracy: ±(1%+5 digit)
AC voltage measuring accuracy: ±(2% + 2 digit)
Type of meter: appliance meter
Measurement: AC current; AC voltage; continuity; DC current; DC voltage; earthing resistance; frequency; insulation resistance; phase sequence; RCD tripping time; resistance
auf Bestellung 1 Stücke:
Lieferzeit 14-21 Tag (e)